RKI Instruments RX-8700 Portable Multi-Gas Monitor, 0-100% LEL & 0-100% Vol HC (isobutane calibration) / 0-40% Oxy / 0-100 ppm H2S & 0-1,000 ppm H2S,with Li-Ion battery & charger - 73-0622

Item #:
73-0622
Brand:
RKI Instruments
RKI Instruments RX-8700 Portable Multi-Gas Monitor, 0-100% LEL & 0-100% Vol HC (isobutane calibration) / 0-40% Oxy / 0-100 ppm H2S & 0-1,000 ppm H2S,with Li-Ion battery & charger - 73-0622
$3,413.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
RKI Instruments RX-8700 Portable Multi-Gas Monitor, 0-100% LEL & 0-100% Vol HC (isobutane calibration) / 0-40% Oxy / 0-100 ppm H2S & 0-1,000 ppm H2S,with Li-Ion battery & charger - 73-0622

RKI Instruments RX-8700 Portable Multi-Gas Monitor, 0-100% LEL & 0-100% Vol HC (isobutane calibration) / 0-40% Oxy / 0-100 ppm H2S...

$3,413.00

RX-8700 Portable Multi-Gas Monitor, 0-100% LEL & 0-100% Vol HC (isobutane calibration) / 0-40% Oxy / 0-100 ppm H2S & 0-1,000 ppm H2S,with Li-Ion battery & charger

*Please note we can only ship RKI products to customers within the United States

Measuring gas
Combustible gas
(HC)
Oxygen
(O2)
Hydrogen sulfide
(H2S)
Measuring principle
Non-dispersive infrared type
Galvanic cell type
Electrochemical type
Measuring range <service range>
0 - 100.0% LEL/ 2 - 100.0 vol%
0 - 25.0 vol% <25.1 - 40.0 vol%>
[Low concentration] 0 - 30.0 ppm <30.5 - 100.0 ppm>
[High concentration] 0 - 1000 ppm
Minimum resolution
0.5% LEL (0 - 100.0% LEL)
0.5 vol% (5.0 - 100.0 vol%)
0.1vol%
0.5ppm
1ppm
Concentration display LCD digital (7-segment + Symbol + Bar meter)
Sampling method Sample-drawing
Suction flow rate 0.75 L/min or more (Open flow rate)
Displays Battery level icon, pilot indicator, and pump operation status indicator
Buzzer sound volume 95 dB (A) or higher (30 cm)
Fault alarm/self diagnosis Low flow rate, battery voltage abnormalities, calibration failure, sensor abnormalities, system abnormalities and clock abnormalities.
Fault alarm display Lamp blinking, intermittent buzzer sounding, and detail display
Fault alarm pattern Self-latching
Transmission method IrDA (for data logger)
Functions LCD backlight, peak display, pump stop, data logger and log data display
Power supply Dedicated lithium ion battery unit [BUL-8000(Z1)] <standard> Or dedicated dry battery unit <AA alkaline dry battery x 3> [BUD-8000(Z)]
Continuous operating time BUL-8000(Z1): About 15 hours (25°C, no alarm, no lighting and battery fully charged) <standard>
BUD-8000(Z): About 8 hours (25°C, no alarm and no lighting) <Option>
Operating temperatures -20 - +50ºC (at a constant condition)
Operating humidities Below 95% RH (Non-condensing)
Structure Drip-proof and dust-proof performances (compliant to IP67 level)
Explosion-proof structure Intrinsically safe explosion-proof structure
Explosion-proof class Ex ia IIC T4 Ga (ATEX/IECEx<Presafe>) / Ex ia llC T4X (TIIS)
Dimensions Approx. 154 (W) x 81 (H) x 163 (D) mm (projection portions excluded)
Weight About 1.3 kg (with BUL-8000(Z1)) <standard> or about 1.1 kg (with BUD-8000(Z)) <Option>