1-866-4 JJSTECH(1-866-455-7832)

RKI Instruments GX-2009 MSHA Four Gas Personal Monitor, 3 Gas, CH4 / O2 / CO with Alligator Clip and 115 / 220 VAC Charger - 72-0311-MSHA-C

Item #:
72-0311-MSHA-C
Brand:
RKI Instruments
RKI Instruments GX-2009 MSHA Four Gas Personal Monitor, 3 Gas, CH4 / O2 / CO with Alligator Clip and 115 / 220 VAC Charger - 72-0311-MSHA-C
$756.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
RKI Instruments GX-2009 MSHA Four Gas Personal Monitor, 3 Gas, CH4 / O2 / CO with Alligator Clip and 115 / 220 VAC Charger - 72-0311-MSHA-C

RKI Instruments GX-2009 MSHA Four Gas Personal Monitor, 3 Gas, CH4 / O2 / CO with Alligator Clip and 115 /...

$756.00

72-0311-MSHA-C GX-2009 MSHA Four Gas Personal Monitor, 3 Gas, CH4 / O2 / CO with Alligator Clip and 115 / 220 VAC Charger by RKI Instruments

RKI is proud to offer the smallest and lightest 4-gas monitor with an MSHA rating, the MSHA GX-2009. MSHA (Mine Safety and Health Administration) certification allows this version of the GX-2009 to be used in underground mines, tunnels and excavations under MSHA jurisdiction. Weighing only 4.6 ounces, it fits in the palm of your hand.

The MSHA GX-2009 simultaneously monitors and displays % volume combustibles, oxygen, carbon monoxide, and hydrogen sulfide. Equipped with dual audible alarm ports and alarm LEDs on 3 sides of the instrument, so that alarm conditions are obvious from multiple perspectives especially in high noise environments. Other features include a water resistant and dustproof design with IP 67 rating, an impact resistant rubber over-mold body that is RFI resistant, and a large capacity data logging system included as standard.

Other standard features are vibration alarm, auto-calibration, calibration and bump test lock out or reminder control, STEL / TWA readings, peak hold, auto backlighting at alarm on a large LCD display, and it even tells the time! All of these controls and features are operated through 2 simple glow-in-the dark, glove friendly buttons. The NiMH battery set will operate for 20 hours and will fully charge in 3 hours.

A huge capacity data logging function is a standard feature on all GX-2009 instruments. The data logging software will store up to 100 calibration records and is Windows 8, 7, XP and Vista compatible. To simplify maintenance and record keeping, the MSHA GX-2009 has the SDM-2009 single calibration station available. The SDM-2009 calibration station can operate as a stand-alone system or connect to a computer along with up to 10 other SDM-2009 units.

Features

  • Simultaneous detection of 4 gases: CH4, O2, H2S & CO
  • Smallest / Lightest 4 gas monitor on the market (2.7" H x 3" W x 1" D, 4.6 oz.)
  • Dual audible alarm ports (95 db @ 30 cm)
  • 3 visual alarm LED's
  • Vibration alarm
  • IP-67 Water resistant/dustproof design
  • Calibration and bump test lock out or reminder controls
  • Large capacity data logging standard (8 alarm trends / Log time range of 10 to 300 hours / 100 calibration records stored)
  • 20 hours of operation (NiMH batteries)
  • Large LCD display screen
  • Automatic backlighting at alarm
  • Impact resistant rubber over-mold body
  • Intrinsically safe, MSHA classified
  • 2 year warranty

Applications

  • Mining
  • Underground construction
  • Tunneling
  • Any application where an MSHA approved gas monitor is required

*Please note we can only ship RKI products to customers within the United States

Gas Detected
Combustible Gases (Methane as standard)
Oxygen (O2)
Hydrogen Sulfide (H2S)
Carbon Monoxide (CO)
Sensor
Catalytic combustion
Galvanic cell
Electrochemical cell
NC-6264B
OS-BM2
ES-1827i
ES-1821
Detection Range (Increments)
0 ~ 5% vol (0.1% vol)
0 ~ 40.0% vol (0.1% vol)
0 ~ 100.0 ppm (0.5 ppm)
0 ~ 500 ppm (1 ppm)
Accuracy Statement
± 5% of reading or ± 0.1% vol (whichever is greater)
± 0.5% O2
± 5% of reading or ± 2 ppm H2S (whichever is greater)
± 5% of reading or ± 5 ppm CO (whichever is greater)
Sampling Method
Diffusion sampling standard / hand aspirator or motorized pump optional
Display
Digital LCD displays all four gases simultaneously, with auto backlight
Preset Alarms (User Adjustable) Overscale alarm (Non-adjustable)
1st alarm 0.5% vol
2nd alarm 2.5% vol
Over alarm 5% vol
Low alarm 19.5%
High alarm 23.5%
Over alarm 40.0%
1st alarm 10 ppm
2nd alarm 30 ppm
TWA alarm 10 ppm
STEL alarm 15 ppm
Over alarm 100 ppm
1st alarm 25 ppm
2nd alarm 50 ppm
TWA alarm 25 ppm
STEL alarm 200 ppm
Over alarm 500 ppm
Types of Alarms
Gas Alarm: 2 Increasing alarms, STEL, TWA, overscale alarm. O2 decreasing/increasing.
Trouble alarm: Sensor disconnection, low battery, circuit error, calibration range error
Display of Alarm
Gas Alarm: Flashing LEDs, intermittent buzzer (95 db @ 30 cm), flashing gas value, vibration
Trouble alarm: Flashing LEDs, intermittent buzzer (95 db @ 30 cm), display of error message
Operating Temp. & Humidity
-4°F to 122°F (-20°C ~ +50°C), 0 to 95% RH, non-condensing (splash resistant)
Response Time
Within 30 seconds (T90)
Continuous Operation
20 hours after a 3 hour full charge (14 hours after 90 min charge)
Power Source
Direct charging NiMH batteries, set of 2
Safety Design / Approvals
MSHA classified
Size & Weight
2.7" H x 3" W x 1" D (Approx. 70 H x 75 W x 25 D mm), 4.6 ounces (approx. 130 g)
Case Material
High impact over molded rubber. Dust and water resistant with IP-67 approval.
Controls
Two glow in the dark buttons: POWER / MODE, AIR
Datalogging
Standard with all instruments. Stores 8 alarm trend sessions where readings are recorded 30 minutes before and after an alarm event. 3,600 data point capacity with a log time range of 10 to 300 hours (based on programmable interval times); and stores up to 100 calibration records.
Required Accessories
Battery charger
Standard Accessories
Alligator clip - 13-0116RK
NiMH batteries (set of 2) - 49-1609RK
Charging station with 115/220 VAC power supply (also available without power supply, 49-2170RK) - 49-2170RK-01
Product CD (includes datalogging software) - 71-8002RK
Optional Accessories
Belt Clip - 13-0117RK
Padded carrying case for GX-2009 and accessories - 20-0112RK-01
Charging station, 115/220 VAC powered for 2, 3, 4, or 5 instruments - 49-2170RK-XX
Charging station with 12 VDC power supply and vehicle adapter plug - 49-2171RK
12 VDC adapter with vehicle plug (does not include charger base) - 49-2020RK
Hand aspirated sample draw with 10' hose and probe (up to 40' hose available) - 81-1160RK
USB to IrDA downloading cable - 47-5027RK
SDM-2009 single calibration station - 81-SDM2009-01
Configurations
4 gas, CH4 / O2 / H2S / CO
3 gas, CH4 / O2 / H2S
2 gas, CH4 / O2
1 gas, CH4
3 gas, CH4 / O2 / CO
Warranty
Two years material and workmanship

Questions & Answers