1-866-4 JJSTECH(1-866-455-7832)

RKI Instruments SP-220 Gas Leak Checker, Type L for LPG - 72-0064-08

Item #:
72-0064-08
Brand:
RKI Instruments
RKI Instruments SP-220 Gas Leak Checker, Type L for LPG - 72-0064-08
$882.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
RKI Instruments SP-220 Gas Leak Checker, Type L for LPG - 72-0064-08

RKI Instruments SP-220 Gas Leak Checker, Type L for LPG - 72-0064-08

$882.00

72-0064-08 SP-220 Gas Leak Checker, Type L for LPG by RKI Instruments

Features

  • Easy grip & Robust structure
  • High speed low conc. reading
  • Data logging function available
  • LED light available

*Please note we can only ship RKI products to customers within the United States

Specification for Type FUM & SC
Model
SP-220 TYPE FUM (Fumigation)
SP-220 TYPE SC (Toxic, Combustible, CFC)
Target gas Refer to the gas list
Detection principle Hot-wire semiconductor method
Sensor SH-8662
Measuring range Depends on target gas
Alarm set point Depends on target gas
Accuracy Displays 0.1 ppm-bar when applied PH3 0.3 ppm.
Alarm pattern Gas alarm: Gas concentration reached or over the setting point.
Trouble alarm: Sensor connection / breaking, Low battery, Low flow Circuit error, Calibration error
Alarm method Non-latching
Display of alarm Gas alarm: Flashing LED, Buzzer
Trouble alarm: Flashing LED, Buzzer, Display of error message
Alarm delay time 0 sec.
Sampling method Sample draw
Response time 10 sec.: Time to reach 0.1 ppm when applied PH3 0.3 ppm.
Output signal IrDA
Switch [AIR][MODE][POWER]
Display device LCD
Display contents Gas name, Gas concentration, Time, Battery, Pilot indicator, Pump driving indicator
Power source 2 AA dry cell batteries
Continuous operation More than 12 hrs.
Operating temp. & humidity -20~+55°C (-4°F~+131°F), 0~95%RH (Non-condensing)
Dimension & weight 200mm(H) x 43mm(D) x 47mm(W) (Taper nozzle not included), 215g
Ingress proof IP 55
Function Manual LCD backlight (Automatically ON when alarming), Peak value, Snap logging, Time, Cal alarm

SP-220 (Type FUM) Gas List
No.
Gas name
Display
Conc. Display1 (ppm)
Display2 (ppm)
Display3 (ppm)
1
Phosphine
PH3
0.1
2
4.5
2
Methyl bromide
CH3Br
1
20
100
3
Carbon disulfide
CS2
0.1
-
-
4
Methyl iodide
CH3l
1
10
30
5
Hydrogen cyanide
HCN
1
-
-
6
Sulfuryl fluoride
SO2F2
-
-
800
7
Ethylene dibromide
C2H4Br2
1
10
30

SP-220 (Type SC) Gas List
No.
Gas name
Display
Conc. Display1 (ppm)
Conc. Display2 (ppm)
1
Phosphine
PH3
0.1
2
2
Acetone
C3H6O
1
10
3
Arsine
AsH3
0.2
-
4
Ammonia
NH3
10
-
5
Isobutane
i-C4H10
1
10
6
Isopropyl alcohol
IPA
1
10
7
Carbon monoxide
CO
10
30
8
Ethyl alcohol
C2H5OH
1
10
9
Ethylene
C2H4
1
10
10
Vinyl chloride
VCM
1
-
11
Methyl chloride
CH3CL
1
10
12
Xylene
C8H10
1
10
13
Ethylene oxide
EO
1
10
14
Silane
SiH4
0.5
1
15
Methyl bromide
CH3Br
1
20
16
Hydrogen
H2
1
10
17
Trichloroethylene
C2HCL3
10
-
18
Toluene
C7H8
1
10
19
1,2-Dichloroethane
EDC
1
10
20
Sulfur dioxide
SO2
1
-
21
Propane
C3H8
5
20
22
CFC R-134a
R-134a
50
250
23
CFC R-22
R-22
10
50
24
CFC R-32
R-32
10
50
25
n-hexane
n-C6H14
10
50
26
Benzene
C6H6
0.5
10
27
Formaldehyde
HCHO
10
50
28
Methane
CH4
1
20
29
Methyl alcohol
CH3OH
1
10
30
Methyl ethyl ketone
MEK
1
10
31
Hydrogen sulfide
H2S
0.1
-
32
Diborane
B2H6
0.1
-
33
Germane
GeH4
0.2
-
34
Hydrogen bromide
HBr
10
-
35
Hydrogen chloride
HCL
10
-
36
CFC R-407C
R-407C
10
50
37
Hydrogen selenide
H2Se
0.5
-
38
CFC R-410A
R-410A
10
50
39
CFC R-404A
R-404A
10
50
40
2,3,3,3- Tetrafluoropropene
CH2C2F4
10
30

Specification for Type M, L & ML
Model
SP-220(TYPE M)
SP-220(TYPE L)
SP-220(TYPE ML)
Detection principle
Hot-wire semiconductor method
Target gas
Town gas (switchable to LPG)
LPG (switchable to town gas)
Town-gas, LPG (switching) *2 gases are needed for calibration.
Concentration display LCD level meter + Scale
Measuring range 10~10000ppm
Sampling method Sample draw
Alarm set point Default:30ppm(selectable from 10,30,150,500,2000ppm)
Display Operating state disp., Flow check disp., Gas concentration disp., Alarm sound disp., Operation sound disp., Battery level icon, Level meter disp., Mode disp., Gas name and message disp.
Response time 3 sec.
Gas alarm display Flashing LED, Buzzer
Gas alarm method Non-latching
Trouble alarm Sensor error, Low battery, Low flow, System error, Calibration error, Clock error, Pump error
Trouble alarm display Flashing LED, Buzzer, Trouble message
Trouble alarm method Latching
Power source 2 AA dry cell batteries
Continuous operation Approx. 13 hrs.
Operating temperature -20~55°C (-4°F~131°F)
Operating humidity 0~95%RH (Non-condensing)
Safety design Intrinsically safety ExiaIICT4
Approvals Ex-proof: IECEx, ATEX / Other: CE marking
Ingress proof IP55
Dimension 200(H) ×43(W) ×39(D)mm (Taper nozzle not included)
Weight 215g (Dry cell batteries not included)

Datasheets & User Manuals

Questions & Answers