1-866-4 JJSTECH(1-866-455-7832)

RKI Instruments T3A Sensor/Transmitter with j-box, Hydrocarbon (CH4), 0-100% LEL catalytic - 66-6340-10

Item #:
66-6340-10
Brand:
RKI Instruments
RKI Instruments T3A Sensor/Transmitter with j-box, Hydrocarbon (CH4), 0-100% LEL catalytic - 66-6340-10
$1,407.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
RKI Instruments T3A Sensor/Transmitter with j-box, Hydrocarbon (CH4), 0-100% LEL catalytic - 66-6340-10

RKI Instruments T3A Sensor/Transmitter with j-box, Hydrocarbon (CH4), 0-100% LEL catalytic - 66-6340-10

$1,407.00

66-6340-10 T3A Sensor/Transmitter with j-box, Hydrocarbon (CH4), 0-100% LEL catalytic by RKI Instruments

The T3A Series Gas Detector ambient air hazardous gas detector is a versatile assembly that uses an electrochemical, infrared, catalytic bead sensor element to detect a variety of gases. Wired power (12 to 35 VDC) with 4-20 mA analog and RS-485 Modbus outputs standard. Magnetic switches allow for non-intrusive calibration while in the field as well as full system settings and diagnostics.

Features

  • Electrochemical, Infrared, catalytic bead sensor element
  • Wire powered (3-Wire), 12 to 35 VDC operating voltage
  • Digital Modbus output
  • Operating temperature range -40°C to +54°C Graphical LCD with LED backlight
  • 3 Push-button interface (ADD, MENU, SUB) with 3 corresponding magnetic, non-intrusive switches
  • 2 Individually configurable alarms
  • 2 Front panel LED indicators (amber and red)
  • 2 Optional fully programmable alarm relays (dry contacts)
  • Output options: 4-20mA (3-wire) analog, RS-485 modbus

Industry Applications

  • Petrochemical plants, Refineries
  • Water & wastewater treatment plants
  • Pulp & paper mills
  • Manufacturing facilities
  • Chemical plants

*Please note we can only ship RKI products to customers within the United States

T2A Specifications:
Sensor Type Electrochemical, infrared, catalytic bead
Power Draw 2 Watts maximum
Operating Voltage Wired power (3-Wire) 12 to 35 VDC
Protection Power electromagnetic interference (EMI) filter
4-20 mA surge suppression
RS-485 surge suppression
Display Screen 102x64 Resolution graphical LCD screen transflective (sunlight readable) with white LED backlight
Interface 3 Push-buttons (MENU, ADD and SUB)
3 Magnetic non-intrusive switches for calibration
Customizable Settings 2 Individual-configurable alarm LED/relay set-points
Temperature Range -40°C to +54°C (-40°F to +130°F)
Output (digital) RS-485 modbus
Wired (Analog) Output 4-20 mA (3-Wire)
Fault terminal
Optional 2 dry-contact relays with replaceable 4 amp fuses
Product Dimensions 5.5 in, L x 6 in. W x 7 in. H (8 in. W x 17 in. H Max. dimensions with attachments)
Total Weight 6 lbs.
Remote Sensor Kit (Optional Additional Feature) Remote sensor kit with enclosure (5 pin)
• Electrochemical sensor max. length: 250 feet
• Infrared sensor max. length: 40 feet
• Catalytic bead sensor max. length: 15 feet
Hazardous Location Approvals Main Enclosure:
Certified explosion / flame proof CQPSUS
Class I, Division 1 & 2, Groups B, C & D
Nema 3, 4, 4X, 7 (B, C, D) 9 (E, F, G)
Temp.= -20°C to +60°C

Sensor Housing:
Certified explosion / flame proof CQPSUS
Class I, Division 1 & 2, Groups B, C & D
Temp.= -40°C to +60°C
Note: Certification only applies to some gases. Toxic gases not certified for Div. 1 locations are suitable for Div. 2 applications but have no third party approval.
Controllers Controllers compatible with all RKI Beacon controllers, as well as most DCS / PLC systems: Beacon 110, Beacon 200, Beacon 410A, Beacon 800, and MC-6400
Sensor Element Warranty 1-Year warranty for electronics and sensor

Gases Detectable Ranges:
Gas Type
Range
T90
Hazard Classification
CL2 0 - 10 ppm < 60 sec. Class 1, Div 2
CLO2 0 - 1 ppm < 120 sec. Class 1, Div 2
CO 0 - 300 ppm < 30 sec. Class 1, Div 1
H2S 0 - 100 ppm < 30 sec. Class 1, Div 1
H2S 2K 0 - 2000 ppm < 25 sec. Class 1, Div 1
HCL 0 - 30 ppm < 300 sec. Class 1, Div 2
HCN 0 - 30 ppm < 70 sec. Class 1, Div 2
HF 0 - 10 ppm < 90 sec. Class 1, Div 2
NH3 0 - 100 ppm < 90 sec. Class 1, Div 2
NH3 300 0 - 300 ppm < 120 sec. Class 1, Div 2
NH3 0 - 1000 ppm < 120 sec. Class 1, Div 2
NO2 0 - 20 ppm < 25 sec. Class 1, Div 2
O2 0 - 25 Vol. < 15 sec. Class 1, Div 1
PH3 0 - 5 ppm < 30 sec. Class 1, Div 2
SO2 0 - 20 ppm < 35 sec. Class 1, Div 2

Datasheets & User Manuals

Questions & Answers