- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Bacharach 6203-0023 MVR-300 Variable Refrigerant Flow Gas Detector, 100-240VAC, Low and High Alarm, Modbus, LED and 80dB Alarm - R-404a, 0 to 10000 ppm
Item #:
6203-0023
Brand:
Bacharach
Share this product:
6203-0023 MVR-300 Variable Refrigerant Flow Gas Detector, 100-240VAC, Low and High Alarm, Modbus, LED and 80dB Alarm - R-404a, 0 to 10000 ppm by Bacharach
The MVR-300 detector is specifically designed to provide continuous monitoring for refrigerants associated with high-efficiency, high volume refrigerant cooling and heating systems, such as VRF/VRV (Variable Refrigerant Flow/Variable Refrigerant Volume) sytems. Typical applications include hotels, dormitories, hospitals, office buildings, and apartment buildings.
The MVR-300 audible and visual alarms alert occupants and simultaneously communicate to Building Management Systems/Building Automation Systems (BMS/BAS). Two on-board relays can be used to close valves, activate alarm devices and exhaust fans or initiate emergency calls to rescue teams.
The on-board Modbus RTU interface provides real-time information about refrigerant concentrations, status and settings. It also enables custom configuration of the MVR-300 to any application specific requirements using multiple Modbus registers. The MVR-300 is designed for easy installation and simple maintenance.
The MVR-300 is compatible with MVR-SC Controller.
Features
- Fits in standard electrical boxes
- Low profile/Flush mount
- Two relays and Modbus Communications
- Alarm options including: LED, buzzer, two levels, configurable delay and failsafe
- Refrigerant specific sensor
- Self diagnostics and simple field calibration
- Unique plug-in field replaceable pre-calibrated sensor
Benefits
- Easy to install
- Aesthetically non-intrusive appearance
- Notify building management & initiate counter measures
- Alert occupants and remotely inform building management of alarm location for rapid response as required
- Enhances safety and minimizes refrigerant loss
- Easy to maintain
- Low cost of ownership
SPECIFICATIONS |
DESCRIPTION |
|||
Detectable Gases | R-410a, R-407c, R-404a, R-32 | |||
Measuring Ranges | 2,500 ppm, 5,000 ppm, 10,000 ppm | |||
Housing | Flush mount, white ABS, Fits in most 2 gang electrical back boxes | |||
Size (L x W x D, approx.) | 6" x 4.1" x 1.75" (150 x 105 x 45 mm) including bezel | |||
Protection | Indoor: IP40, NEMA 1 | |||
Weight (approx.) | 8 oz (230 g) | |||
Power | 100 to 240 VAC, 50/60 Hz, 4 W max | |||
Indicator | Tri-color LED: green, amber, red | |||
Buzzer | 80 dB at 12" (30 cm) | |||
Relay | Two SPDT: low alarm and high alarm / fault, normal or fail-safe, configurable | |||
Alarm Delay | 0 to 15 minutes, configurable 0, 5, 10, 15 | |||
Wiring | Power: 3-core cable, 14 to 20 AWG (0.5 to 2.0 mm2) Relay: 3-core cable, 18 to 20 AWG (0.5 to 1.0 mm2) Modbus: 2-core twisted pair shielded cable 18 to 24 AWG |
|||
Modbus RTU | Baud Rate: 9,600 or 19,200, configruable | |||
Environmental Conditions | Operating Temperature: 32 to 120 °F (0 to 50 °C) Storage Temperature: 5 to 100 °F (-20 to 40 °C) Humidity: 5 to 90% RH, non-condensing Pressure: 23.6 to 32.5 inch of Hg (800 to 1,100 hPa) |
|||
Elevation | 0 to 6,560 ft. (2,000 m) altitude | |||
Sensor Life | 2 year minimum life with recommended 6 month testing and/or recalibration | |||
Approvals | CE, UL/SCA/IEC/EN 61010-1 | |||
REFRIGERANT |
P/N |
LOW ALARM |
HIGH ALARM |
RANGE |
R-410a | 6203-0001 6203-0002 6203-0003 |
500 ppm 1,000 ppm 2,000 ppm |
2,000 ppm 2,000 ppm 4,000 ppm |
2,500 ppm 5,000 ppm 10,000 ppm |
R-407c | 6203-0011 6203-0012 6203-0013 |
500 ppm 1,000 ppm 2,000 ppm |
2,000 ppm 2,000 ppm 4,000 ppm |
2,500 ppm 5,000 ppm 10,000 ppm |
R-404a | 6203-0021 6203-0022 6203-0023 |
500 ppm 1,000 ppm 2,000 ppm |
2,000 ppm 2,000 ppm 4,000 ppm |
2,500 ppm 5,000 ppm 10,000 ppm |
R-32 | 6203-0041 6203-0042 6203-0043 |
500 ppm 1,000 ppm 2,000 ppm |
2,000 ppm 2,000 ppm 4,000 ppm |
2,500 ppm 5,000 ppm 10,000 ppm |