- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Bacharach 6202-1140 IAM-100 Gas Detector, STD Housing, R134a 0-10,000 ppm, 220 VAC
Item #:
6202-1140
Brand:
Bacharach
Share this product:
6202-1140 IAM-100 Gas Detector, STD Housing, R134a 0-10,000 ppm, 220 VAC by Bacharach
The IAM-100 Gas Monitor from Bacharach offers exceptional continuos monitoring performance and flexibility at an economical price. By itself, or integrated into a comprehensive detection system, the IAM-100 is a scalable solution for detecting a variety of refrigerants, combustible gases and VOC gas leaks at the lowest possible cost.
Onboard LEDs illuminate when the sensor is in an alarm state while the unit's audible alarm alerts personnel in the area that levels have exceeded the desired limit. The audible alarm can be muted with the onboard silence switch. Integrated dual relays enable the IAM-100 to shut-off refrigerant or propane supply lines while the second relay can be used as a connection to a building BMS or BAS system.
The IAM-100 is an alarm threshold device. When the range of the sensor is exceeded, the detector will go into alarm. For example, a unit with a 1,000 ppm R-410a sensor will activate its alarm when the detected refrigerant meets or exceeds 1,000 ppm.
Features & Benefits:
- Real-time continuous gas detection that's scalable, reliable and affordable
- Ideal for commercial applications such as hotel rooms, apartments, dorms, hospitals, restaurant kitchens or battery charging rooms
- Detects refrigerants (at ?1,000 or ?10,000 ppm), TVOCs (at ?1,000 ppm), combustible gases and hydrocarbons (at ?5,000 ppm)
- Fast-responding, long-life sensors
- Integrated visual LED and audible alarms
- Two onboard relays to activate shut-off valves, exhaust fans, or connect to a BMS or fire panel
- Remote sensor with aesthetic faceplate available for discreet monitoring in decorative interiors
IAM-100 | IAM Controller | |
Operating Power Supply | 110 VAC/60 HZ or 220 VAC/50 Hz; 11 W Max | 110 VAC/60 HZ or 220 VAC/50 Hz; 11 W Max |
Power Status | Green LED | Green LED |
Alarm Status | Red LED | Red LED |
Fault Status | Siren inactive, Green LED off, and Red LED on | Siren inactive, Green LED off, and Red LED on |
Audible Alarms | Internal siren with mute button | External siren with mute button |
Siren Deactivate | By onboard jumper | By key switch |
Alarm Relays (Volt Free) | 2 Relays: 1 A @ 24 VDC | 2 Relays: 10 A @ 230/120 VAC |
Alarm Reset | Selectable manual or automatic | Remote reset, down stream resets any IAM-100 monitor or controller connected to a channel, after gas has cleared |
Selectable Alarm Delay | 0, 5, 10 or 15 minutes | N/A |
Warm-up Delay | 5 minutes initially | N/A |
Enclosure Rating | Standard: IP30 | IP51 |
Cable Recommendations | IAM to IAM-C: 16-24 AWG, 2-conductor (7/0.2 mm, 2 conductor) 984.25 ft (300 m) max |
IAM-C to IAM-C: 16-24 AWG, 2-conductor (7/0.2 mm, 2 conductor) 984 ft (300 m) max |
Approvals | CE UL/CSA 61010-1 |
CE FCC Part 15, Subpart B UL/CSA 61010-1 |
Standard Housing | Size: 147x88x62 mm (5.8x3.5x2.4 in) Weight: 633 g (1.4 lbs) |
|
Faceplate (Brushed Steel) Housing | Size: 86x86 mm (3.4x3.4 in) Weight: 86 g (0.2 lbs) |
|
Measurement Range | 10 to 10,000 ppm (typical) | |
Temperature Range | -4 to 122ºF (-20 to +50ºC) | |
Humidity Range | 0 to 95% Non condensing | |
Sensor Life Time | 5 to 8 years (typical) for semiconductor sensors | |
Typical Time to Alarm | 24 seconds (Response times may vary based on temperature of operation, enclosure and environmental conditions) | |
Calibration Frequency | See local regulations (annual test or calibration typical). Semiconductor sensors are non-selective, but calibrated to a specific gas. |
Gas Type |
Formula/Name |
Detection Range |
Standard Alarm Setpoints |
HFCs |
R134a, R404A, R407, R410A, R507 |
≥1,000 ppm or ≥10,000 ppm |
Refrigeration: 1,000 ppm Air Conditioning: 10,000 ppm |
HCFCs |
R22 |
≥1,000 ppm or ≥10,000 ppm |
Refrigeration: 1,000 ppm Air Conditioning: 10,000 ppm |
CFCs |
R11, R12 |
≥1,000 ppm or ≥10,000 ppm |
Refrigeration: 1,000 ppm Air Conditioning: ...................... |
Hydro-carbons |
Methane (Natural Gas), Propane, Butane, LPG, Isobutane, H2 |
≥5,000 ppm |
5,000 ppm |
VOCs |
Acetone, Chloroform, Ethanol, Methanol, Methyl and Methylene Chloride, Ethyl and Ethylene Chloride |
≥1,000 ppm |
1,000 ppm |