- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
RKI Instruments 12-Channel 570 Wall Mounting Housing with Buzzer Module - 570-12WB
Item #:
570-12WB
Brand:
RKI Instruments
Share this product:
570-12WB 12-Channel 570 Wall Mounting Housing with Buzzer Module by RKI Instruments
Features:
- Available to connect to various gas sensor
- Easy to read three color (green/orange/red) LED bar-graph display (52 segments)
- Combustible gases detectable in wide range (from PPM to %LEL) with one display unit (NC-581W)
- Automatically changes from ppm range to %LEL range (NC-581W)
- Two alarm levels
- Peak hold function
- Highly integrated compact design with plug-in type unit
- Zero suppression function
- Alarm contact interruption function (Maintenance mode)
- Alarm test mode
- Auto zero function
- Ability to indicate a flow failure alarm
- Output signal (4~20mADC) is provided
Applications:
- Petro-refinery, petrochemical plants
- Chemical plants
- Semi-conductor manufacturing plants
- Engineering public work field
- Power station, gas work
- Iron and steel works
*Please note we can only ship RKI products to customers within the United States
Power Requirements | 115 VAC and 24 VDC with 230 VAC optional |
Sampling Method | Accepts both diffusion and sample drawing type detector heads |
Operating Conditions | 0 - 122 º F, 10 - 90% RH, non-condensing |
Enclosure Type | Metal module |
Mounting Style | Wall mount for 4, 6, or 12 modules |
Display Method | 3 color LED bar graph (52 segments) |
Alarms | 2 per module, 2 common relays, external reset |
Alarm Indication | 1st alarm flashing LED (orange), latched, continuous light when reset 2nd alarm flashing LED (red), latched mode |
Output Signal | 4-20 mA DC |
Audible Alarm | Enclosure mounted buzzer, 94 dB at 1' Coded output: pulsing = gas alarm, steady = fail |
Sensor Inputs | Any 4-20 mA transmitter, 24 VDC, 2 or 3 wire, 250 mA max standard. LEL or Oxygen sensors direct connect. |
Warranty | One year materials and workmanship |
Ammonia (NH3) | 0 - 75.0 ppm |
Arsine (AsH3 ) | 0 - 0.20 ppm |
Boron Trichloride (BCl3) | 0 - 15.0 ppm |
Carbon Dioxide (CO2) | 0 - 1.0 % |
Carbon Monoxide (CO) | 0 - 300 ppm |
Chlorine (Cl2) | 0 - 3.0 ppm |
Chlorine Dioxide (ClO2) | 0 - 1.00 ppm |
Chlorine Trifluoride (ClF3) | 0 - 1.00 ppm |
Combustibles | 0 -100% LEL |
Diborane (B2H6) | 0 - 30.0 ppm |
Fluorine (F2) | 0 - 6.0 ppm |
Hydrogen (H2) | 0 - 2000 ppm |
Hydrogen Chloride (HCl) | 0 - 15.0 ppm |
Hydrogen Fluoride (HF) | 0 - 9.0 ppm |
Hydrogen Sulfide (H2S) | 0 -100.0 ppm |
Nitric Oxide (NO) | 0 -100.0 ppm |
Nitrogen Dioxide (NO2) | 0 - 15.0 ppm |
Nitrogen Trifluoride (NF3) | 0 - 30.0 ppm |
Oxygen (O2) | 0 - 25.0 % |
Ozone (O3) | 0 - 1.0 ppm |
Phosphine (PH3) | 0 - 1.0 ppm |
Silane (SiH4) | 0 - 15.0 ppm |
Sulfur Dioxide (SO2) | 0 - 30.0 ppm |
TEOS (Si(OC2H5)4) | 0 -15/30 ppm |