1-866-4 JJSTECH(1-866-455-7832)

Testo 330-1G Long Life Kit #4 - NOx Analyzer Kit - 400563 3304

Item #:
400563-3304
Brand:
Testo
$3,455.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Testo 330-1G Long Life Kit #4 - NOx Analyzer Kit - 400563 3304

Testo 330-1G Long Life Kit #4 - NOx Analyzer Kit - 400563 3304

$3,455.00

400563 3304 330-1G Long Life Kit #4 - NOx Analyzer Kit by Testo

Thanks to the new instrument functions, the Testo flue gas analyzers of the new testo 330-LL series now offer you even more professional and reliable support.

Kit Includes:

  • 0632 3306 00 - 330-1G LL Combustion Analyzer
  • 0554 2151 - NO upgrade module 0-3000 ppm (high range, 1 ppm res)
  • 0600 9763 - 12" flue gas probe, 1/4" dia., w/ 7' hose
  • 0554 1096 - Power supply / recharger (North American cord)
  • 0554 0549 - Fast IR printer
  • 0554 0568 - Thermal printer paper - 6 rolls (10 year legibility)
  • 0554 3385 - Particle filters - pack of 10
  • 0516 3330 - Standard case

  • Graphic processing of measurement data
  • Instrument diagnosis function uses easy "traffic light" presentation to enable comprehensive instrument diagnosis
  • Pressure measurement up to 300 mbar
  • User-defined fuels
  • TÜV-tested according to 1. BImSchV / EN 50379 Part 2 for O2, °C, hPa and CO with H2-compensation
  • Powerful memory management: 500,000 readings
  • IrDa/ Bluetooth interface for data transfer to Pocket-PC / laptop / printer
  • USB interface for data readout to a PC software
  • ZIV (Central Guild Association) driver for all standard industry software packages
Memory 500.000 readings
Display Colour graphic display with 240 x 320 Pixel
Storage temperature -20 to +50 °C
Operating temperature -5 to +45 °C
Weight 600 g
Dimensions 270 x 90 x 65 mm
Probe type Type K Meas. Range: -40 to +1200 °C
Resolution: 0.1 °C (-40 to 999,9 °C); 1 °C (remaining range)
Probe type CO Meas. Range: 0 to 500 ppm
Accuracy: ±5 ppm (0 to 100 ppm); ±5% of mv (>100 ppm)
Resolution: 1 ppm
Response time: Approx. 35 s
Probe type CO2 Meas. Range: 0 to 1 Vol. %; 0 to 10.000 ppm
Accuracy: ±(50 ppm ±2% of mv) (0 to 5000 ppm)
Response time: Approx. 35 s
Probe type Differential pressure Meas. Range: 0 to 300 hPa
Accuracy: ±0.5 hPa (0.0 to 50.0 hPa); ±1% of mv (50.1 to 100.0 hPa); ±1.5 % of mv (remaining range)
Resolution: 0.1 hPa
Probe type Draught measurement Meas. Range: -9.99 to +40 hPa
Accuracy: ±0.02 hPa or ±5% of mv (-0.50 to +0.60 hPa); ±0.03 hPa (+0.61 to +3.00 hPa); ±1.5% of mv (+3.01 to +40.00 hPa)
Probe type Exhaust gas loss measurement Meas. Range: 0 to 99.9%
Resolution: 0.1%
Probe type Electrochemical measurement CO Meas. Range: 0 to 4000 ppm
Accuracy: ±20 ppm (0 to 400 ppm); ±5% of mv (401 to 1000 ppm); ±10% of mv (1001 to 4000 ppm)
Resolution: 1 ppm
Probe type Electrochemical measurement NO Meas. Range: 0 to 3000 ppm
Accuracy: ±5 ppm (0 to 100 ppm); ±5% of mv (101 to 2000 ppm); ±10% of mv (2001 to 3000 ppm)
Resolution: 1 ppm
Probe type Electrochemical measurement O2 Meas. Range: 0 to 21 Vol. %
Accuracy: ±0.2 Vol. %
Resolution: 0.1 Vol. %
Probe type Efficiency Measurement (Eta) Meas. Range: 0 to 120%
Resolution: 0.1%
Probe type CO2-determination Meas. Range: 0 to CO2 max
Accuracy: ±0.2 Vol. %
Reaction time t90: < 40 s