3015-5532 CO2-MZ 8 Zone Carbon Dioxide Monitor with Remote Display, 120-240 VAC / 50/60Hz Input Power by Bacharach

Bacharach's Multi-Zone Gas Leak Monitors offer superior performance, flexibility and functionality for low level continuous monitoring of refrigerant gases used in most commercial systems including: Chlorofluorocarbons (CFC), Hydrochlorofluorocarbons (HCFC), Hydrofluorocarbons (HFC), Ammonia (NH3) and Carbon Dioxide (CO2). These state-of-the-art fixed gas monitors lead the industry in performance, integration capabilities, initial cost and cost of ownership. Capable of detecting more than 38 refrigerant gases, the Multi-Zone system is compliant with ASHRAE standard 15-2007, is ETL Energy Saving Listed, meets California Code Regulations for Refrigerant Monitors and is EN 14624 and CE certified.

Bacharach Multi-Zone Monitors provide continuous detection of refrigerant gas levels in up to 16 separate test zones and can be fitted with an optional two channel 4-20 mA current loop board for connection to remote monitoring equipment. Multi-Zone monitors retain a log of previous readings that can be easily accessed for analysis. Four relay contacts are provided that can be programmed to trigger external alarm devices in the event of a system fault, or if a leak (small), spill (medium) or evacuation (large) level of gas is detected, while audible and visual front panel indicators show alarm and fault conditions. With only minor periodic maintenance, such as the occasional replacement of filters, and active diagnostics that continuously check the system for proper operation, Multi-Zone monitors help maintain your equipment efficiency, promote safety and protect the environment.

Ideal for Chillers, Grocery Stores, Mechanical Rooms Physical Plants, Refrigeration Racks, Walk-In Freezers

Features & Benefits:

  • Proprietary infrared sensing technology virtually eliminates false alarms and extends sensor life
  • No calibration required
  • Low detection limits enable leaks to be found early reducing energy and refrigerant consumption
  • Fastest sampling rate with the longest sampling distance in the industry at 1,200 feet
  • Large Graphic LCD for easy set-up and real-time monitoring
Product Type The Multi-Zone Gas Leak Monitor is a multiple area monitoring system for low level continuous monitoring of refrigerant gases used in most commercial
systems including: CFC, HCFC, HFC, Ammonia and Carbon Dioxide. System design supports compliance to the gas monitoring requirements of ANSI/BSR ASHRAE 15-2007.
Coverage 4 Point Standard, Expandable to 16 Points in 4 Point Increments
Detector Type Single-Pass, Non-Dispersive (NDIR)
Gas Library:
HGM-MZ CFC: R11, R12, R113, R114, R502, HFP
HFC: R404A (HP62), R407A, R407C (AC9000), R134A, R410A (AZ20), R507 (AZ50
HCFC: R21, R22, R23, R123, R124, R227, R500, R503, R401A (MP39), R402A (HP80), R402 (HP81), R408A, R409A, R508B (SUVA95), R236FA, R125, R245FA, R422A, R422D, R427A
Halon: H1301, H2402, H1211
Other: FA188, FC72, N1230, HFO1234YF, R424A, R426A, R427A, R438A
AGM-MZ Ammonia (NH3), R717
CO2-MZ Carbon Dioxide (CO2), R744
Measuring Range:
HGM-MZ All gases 0 to 10,000 ppm
AGM-MZ Ammonia 25 to 10,000 ppm
CO2-MZ Carbon Dioxide 0 to 8,000 ppm
Accuracy:
HGM-MZ ±1 ppm ±10% of reading from 0-1,000 ppm (R11, R22, R13: ±10 ppm ±15% of reading 0-1,000 ppm)
AGM-MZ ±10 ppm ±10% of reading from 0-1,000 ppm
CO2-MZ ±5 ppm ±5% of reading from 0-1,000 ppm, ±10% of reading from 1,000 to 4,000 ppm, ±15% of reading 4,000 to 8,000 ppm
Temperature Drift:
HGM-MZ ±0.8% (R134A) of reading per Degrees C between purge cycles
AGM-MZ 1.5 ppm per Degrees C between purge cycles
CO2-MZ Less than 1 ppm per Degrees C between purge cycles
Other Specifications:
Display Resolution 1 ppm
Dimensions 12.23" x 13.7" x 4.96" (31.0642 cm x 34.798 cm x 12.5984 cm)
Weight 15 lbs (6.80kg)
User Interface Front panel w/3 indicator lights: Green - Power On, Normal; Yellow - Fault; Yellow Flashing - System Fault; Red/Flashing - point has exceeded alarm set.
Communications Full 2-way communication with MZ-RD display module or building management system via RS-485 Serial Interface. RS-232C Comm. Port Standard.
Alarms Four SPDT alarm contacts are provided rated 2A at 250 VAC (Inductive), 5A at 250 VAC (Resistive). Three assigned to ppm level alarms. One assigned to system faults.
Conditioned Signal Optional Dual 4-20 mA DC isolated outputs. Channel 1=zone area, Channel 2=ppm
System Noise Less than 40dB at 10 Ft. (3m)
Response Time 5 to 315 seconds – Depending on air line length and number of zones
Sampling Mode Automatic or Manual (Hold)
Re-Zero Every 5 minutes or on 0.5 Degree C internal temperature change
Monitoring Distance 1,200 ft. max. (500 ft. for NH3) for combined length of sample and exhaust tubing (each zone)
Power Safety Mode Fully automatic system reset. All programmed parameters retained
Operating Temp 32° to 122° F (0 to 50° C)
Ambient Humidity 5% to 90% RH Non-condensing
Altitude Limit 6,562 Ft. (2,000 m)
Power 100 to 240 VAC, 50/60 Hz, 20 W
Approvals UL 61010-1, CAN/CSA 22.2 No. 61010-1; EN61010-1, EN61326, EN14624; CE Mark