Bacharach 3015-4601 CO2-SZ Single Zone Monitor, 120-240 VAC / 50/60Hz Input Power

Bacharach 3015-4601 CO2-SZ Single Zone Monitor, 120-240 VAC / 50/60Hz Input Power

$5,632.90

3015-4601 CO2-SZ Single Zone Monitor, 120-240 VAC / 50/60Hz Input Power by Bacharach

Bacharach's Single-Zone delivers the best refrigerant leak monitoring available, with industry-leading MDL of 1 ppm for halogenated gases, the fastest sampling frequency and the widest range of refrigerants accurately detected.

The Single-Zone is the ideal tool for early detection of leaks from specific target areas such as chiller rooms and mechanical rooms. The low MDL enables detection of leaks that other instruments can't find, enhances effective refrigerant management and delivers cost savings through reduced refrigerant recharge and enhanced energy efficiency. Communication interfaces are available allowing easy integration into BMS/BAS systems and remote monitoring solutions.

Features

  • 1 ppm Minimum Detectable Level
  • Early detection of refrigerant leaks
  • Over 50 different refrigerants accurately detected
  • Infrared sensor technology
  • High performance sampling pump
  • Minimal maintenance and no calibration required
  • Halogen, CO2 and NH3 versions available

Benefits

  • Detects leaks that other instruments can't
  • Mitigate refrigerant loss, protect produce, enhance energy efficiency
  • Select from a wide range of refrigerant calibration to meet project needs
  • Accurate, precise measurement unaffected by other gases, temperature or humidity
  • Fast response times, including extended sample lines
  • Low cost of ownership
  • Suitable for a variety of refrigerant monitoring applications

Includes

  • 1 x line-end filter
  • 1 x charcoal filter with mounting bracket
  • 50ft sample tubing
PRODUCT ATTRIBUTES DESCRIPTION
Sensor Proprietary non-dispersive infrared (NDIR) technology
Display Resolution 1 ppm
Dimensions 13.7" x 7.7" x 3.6" (347.98 mm x 195.58 mm x 91.44 mm)
Weight 7 lbs (3.175 kg)
User Interface Front panel w/3 indicator lights: Green - power on, normal; Yellow - fault; Yellow Flashing - system fault; Red Flashing - point has exceeded alarm set
Alarms 3 SPDT, 3 amp, 250 VAC rated alarm relays and 1 SPDT, 3 amp, 250 VAC rated system fault relay, plus a digital display with dedicated 4-20 mA DC analog output (floating ground)
System Noise Less than 40dB at 10 ft (3m)
Response Time 9 to 90 seconds, depending on sample length tube
Sampling Mode Automatic or manual (hold)
Re-Zero Every 5 minutes or on 0.5 degree C internal temperature change
Monitoring Distance 1,200 ft max (500 ft for NH3) for combined length of sample and exhaust tubing (each zone)
Power Safety Mode Fully automatic system reset. All programmed parameters retained
Operating Temperature 32° to 122° F (0 to 50° C)
Ambient Humidity 5% to 90% RH non-condensing
Altitude Limit 6,562 ft (2,000 m)
Power 100 to 240 VAC, 50/60 Hz, 20 W
Approvals UL 61010-1, CAS 22.2 No. 61010-1, EN 14624, CE Mark
MEASUREMENT UNIT DESCRIPTION
Gas Library HGM-SZ FA188, FC72, H1211, H1233ZD, H1234YF, H1234ZE, H1301, H2402, HFP, N1230, N4710, N7100, N7200, N7300, N7600, R-11, R-113, R-114, R-12, R-123, R-124, R-125, R-134a, R-21, R-22, R-227, R-23, R-236fa, R-245fa, R-32, R-401A, R-402A, R-402B, R-404A, R-407A, R-407C, R-407F, R-408A, R-409A, R-410A, R-422A, R-422D, R-424A, R-426A, R-427A, R-438A, R-448A, R-449A, R-452A, R-452B, R-500, R-502, R-503, R-507, R-508B, R-513A, R-514A, R-1233zd
AGM-SZ Ammonia (NH3), R717
CO2-SZ Carbon Dioxide (CO2 ), R744
Measuring Range HGM-SZ All gases 0 to 10,000 ppm
AGM-SZ Ammonia 25 to 10,000 ppm
CO2-SZ Carbon Dioxide 0 to 8,000 ppm
Accuracy HGM-SZ 1 ppm Minimum Detectable Level (MDL) (most gases)
±1 ppm ±10% of reading from 0-1,000 ppm (most gases)
±1 ppm ±2% of reading with field calibration (most gases)
±10 ppm ±15% of reading from 0-1,000 ppm (R-11, R-21, R-32, R-113)
AGM-SZ ±20 ppm ±10% of reading from 25 to 1,000 ppm
CO2-SZ ±5 ppm ±5% of reading from 0-1,000 ppm, ±10% of reading from 1,000 to 4,000 ppm, ±15% of reading 4,000 to 8,000 ppm
Temperature Drift HGM-SZ ±0.8% (R-134a) of reading per degree C between purge cycles
AGM-SZ 1.5 ppm per degree C between purge cycles
CO2-SZ Less than 1 ppm per degree C between purge cycles