- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Bacharach 3015-4200 HGM-SZ Single Zone Monitor, 120-240 VAC / 50/60Hz Input Power
Item #:
3015-4200
Brand:
Bacharach
Share this product:
3015-4200 HGM-SZ Single Zone Monitor, 120-240 VAC / 50/60Hz Input Power by Bacharach
The Bacharach Single-Zone family of fixed point gas monitors is available for the detection of refrigerants, halogen gases (HGM-SZ) and ammonia (AGM-SZ). The Single-Zone series is designed around Bacharach’s proprietary infrared sensing technology to offer reliable, superior sensing performance.
Bacharach's infrared (NDIR) sensors offer users one of the most feature loaded, lowest-cost-of-ownership monitors available. The Single-Zone monitors feature automatic calibration, eliminating the need for costly calibrations. Periodic filter replacements are practically the only maintenance required.
An easy-to-install, out-of-the-box solution, Bacharach's Single-Zone monitors offer an onboard power supply, LCD display for real-time readings and LED indicators with dedicated relays that activate audible or visual alarms. A 4-20 mA output enables a compatible connection to standard building automation systems.
Features & Benefits:
- Proprietary infrared sensing technology virtually eliminates false alarms and extends sensor life
- Capable of detecting and measuring any CFC, HFC, and HCFC refrigerant gas or ammonia
- Provides continuous, unattended monitoring from up to 500 ft. (152.4 m) away from measuring point
- Measurement range of 0-10,000 ppm with sensitivity of 1 ppm
- Logging feature enables 200 gas readings to be stored at user-selectable time intervals
- No costly calibration required
Part Number | 3015-4200 |
Includes | HGM-SZ single zone monitor with: 1 termination filter, 15.24 m (50 ft.) of sample line tubing. |
Measures | R-11, R-12, R-22, R-23, R-113, R-114,
R-123, R-124, R-125, R-134a, R-227,
R236FA, R-401a, R-402a, R402b,
R-404a, R-407a, R-407c, R-408a, R-409a, R-410a, R-500, R-502, R-503, R-507, R-508b, H-1211, H-1301, H-2404, N-1230 |
Measuring Range | 0 to 1,000 ppm |
Sensitivity | 1 ppm |
Accuracy | ± 1 ppm ± 10% of reading from 0 to 1,000 ppm |
Detector Type | Single-pass Non-Dispersive Infrared (NDIR) |
Inputs | Dedicated single zone |
Output Signal | 3 SPDT, 3 Amp, 250 VAC rated alarm relays and 1 SPDT, 3 Amp, 250 VAC rated system fault relay, plus a digital display with dedicated 4-20 mA DC analog output (floating ground) |
Monitoring Distance | Maximum 152.4 m (500 ft.) from measuring point to monitor |
Response Time | 9 to 90 seconds, depending on sample tube length |
Front Panel Display | Green LED: indicates unit is operating properly Yellow LED: indicates clogged sample line or other system fault Red LED: indicates when any monitored point exceeds alarm settings |
Power | 100 to 240 VAC, 50/60 Hz |
Size / Weight | 13.7" x 7.7" x 3.6" / 7 lbs. (347.98 mm x 195.58 mm x 91.44 mm / 3.175 kg) |
Approvals | UL 61010-1 • CSA 22.2 No. 61010-1 • EN 14624 • CE Mark |