1-866-4 JJSTECH(1-866-455-7832)

Honeywell Analytics 301-EM Controller with Horn & Strobe Type 2 Canada - 301-EM-RFSA-CA2

Item #:
301-EM-RFSA-CA2
Brand:
Honeywell Analytics
Honeywell Analytics 301-EM Controller with Horn & Strobe Type 2 Canada - 301-EM-RFSA-CA2
$2,761.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Honeywell Analytics 301-EM Controller with Horn & Strobe Type 2 Canada - 301-EM-RFSA-CA2

Honeywell Analytics 301-EM Controller with Horn & Strobe Type 2 Canada - 301-EM-RFSA-CA2

$2,761.00

301-EM-RFSA-CA2 301-EM Controller with Horn & Strobe Type 2 Canada by Honeywell Analytics

Delivers sophisticated control functionality for up to twenty remote refrigerant sensors and detects a wide variety of gases. Protects personnel and property when mounted in mechanical or chiller rooms. Optional horn and strobe will quickly alert personnel when gas is detected.

Product Overview:

Easily configured to meet ASHRAE 15, B-52 and International Mechanical Code requirements, the 301EM is commonly used to optimise gas detection in mechanical and chiller rooms.

A full complement of sensors (including toxic, Oxygen, combustible gases and a full line of refrigerant sensors), horns, strobes and remote panels provide added flexibility to suit a variety of gas detection system solutions.

ASHRAE No 15-2001 Mechanical Standard and B-52 Code Compliance. The ASHRAE and B-52 security standards have been established to minimise risk and protect the safety of mechanical room personnel and the environment at large. Available in a special configuration, the 301EM mechanical room controller has been carefully designed to meet and even exceed these rigorous standards. The Vulcain 301EM can be configured to offer automatic fan, horn and strobe activation in addition to manual fan activation. Latching relay for manual alarm recognition, silence key for manual horn deactivation, built-in 24 Vdc outputs for horn operation, and 2 breakglass switch accessories for manual alarm activation ensure optimal performance.

User Friendly:

  • Easy to read LCD display
  • Auto-diagnostic capabilities

Economical Solution:

  • Cost-effective answer for installation in hazardous locations

Flexible Operation:

  • Able to operate with up to twenty remote sensors at a time
  • Various sensors available to simultaneously detect a range of different gases
  • Robust and reliable RS-485 Modbus communication

Output Adaptability:

  • Three 24 Vdc alarm outputs and four 4-20 mA outputs

Safety Measures:

  • Four fully programmable relays
  • Three alarm levels with built-in visual indicators and audible alarm

Beneficial Options:

  • Convenient stand-alone or network operation
  • Datalogging option

Features & Benefits:

  • Easy to read LCD display
  • Auto-diagnostic capabilities
  • Convenient stand-alone or network operation
  • Three alarm levels
  • Combine with 301IRF and S301D2 sensors for a complete solution.

Quick Specs:

  • Power requirement: 22-27 VAC, 29-38 VDC, 2A max @ 29 VDC
  • Size: 11 (H) x 8 (W) x 2.7 (D) in. (28 x 20.3 x 7cm)
  • Weight: 2.25 lbs. (1.02 kg)
General Specification
Use Wall mounted mechanical room controller for use with Honeywell Analytics 301IRFS and S301D2 gas sensors for up to 20 points of detection. Four (4) onboard relays can be used to activate alarms or deactivate equipment.
Power Requirement 22-27 Vac, 29-38 Vdc, 2A max @ 29Vdc
Size 11 (H) x 8 (W) x 2.7 (D) in. (28 x 20.3 x 7 cm)
Weight 2.25 lbs. (1.02 kg)
Distance Between Controller and Sensor 301IRFS refrigerant sensors: Up to 200 ft. (60.9 m)
S301D2 toxic/combustible sensors: Up to 500 ft. (160 m)
Visual Indicators Normal Operation: Green LED
Alarm Level 1: Red LED
Alarm Level 2: Red LED
Alarm Level 3: Red LED
Signal Tx: Blinking amber LED
Failure Indication: Yellow LED
Alarm Levels 3 with high and low setpoints
Outputs 4 DPDT relays (alarms and/or fault), buzzer
Three 24 Vdc, 250mA (per output)
Four 4-20mA outputs
Modbus
RFS option: 24 Vdc built-in red strobe
RFSA option: 24 Vdc built-in red strobe & 105 dBA horn
Relay Output Rating 5 A, 30 Vdc or 250 Vac (resistive load)
Gases Detected
301IRFS Gases Detected Detection Range Operating Temperature Operating Humidity Range
  R11, R22, R123, R125, R134A, R404A, R407C, R410A, R507A 0-1,000 ppm 32° to 104°F (0° to 40 °C) 0-95% non-condensing
S301D2 Gases Detected Detection Range Operating Temperature Operating Humidity Range
  Carbon Monoxide (CO) 0-250 ppm -40° to 100°F (-40° to 40°C) 0-95% non-condensing
  Chlorine (Cl2 0-15 ppm -40° to 100°F (-40° to 40°C) 0-95% non-condensing
  Nitrogen Dioxide (NO2) 0-10 ppm -40° to 100°F (-40° to 40°C) 0-95% non-condensing
  Hydrogen Sulfide (H2S) 0-50 ppm -40° to 100°F (-40° to 40°C) 0-95% non-condensing
  Sulfur Dioxide (SO2) 0-10 ppm -40° to 100°F (-40° to 40°C) 0-95% non-condensing
  Oxygen (O2) 0-25% -4° to 104°F (-20° to 40°C) 0-95% non-condensing
  Combustibles 0-100% LEL -40° to 112°F (-40° to 50°C) 0-95% non-condensing
Ratings and Certification
Alarm Levels CAN/CSA C22.2 No. 61010-1
Conforms to ANSI/UL 61010-1

Questions & Answers