1-866-4 JJSTECH(1-866-455-7832)

GfG Dynagard 25 for O2 Stand-alone System with ZD 21 Transmitter for Detecting Oxygen (O2) and GMA 41B Single Channel Controller - 2210-030

Item #:
2210-030
Brand:
GfG
GfG Dynagard 25 for O2 Stand-alone System with ZD 21 Transmitter for Detecting Oxygen (O2) and GMA 41B Single Channel Controller - 2210-030
$2,295.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
GfG Dynagard 25 for O2 Stand-alone System with ZD 21 Transmitter for Detecting Oxygen (O2) and GMA 41B Single Channel Controller - 2210-030

GfG Dynagard 25 for O2 Stand-alone System with ZD 21 Transmitter for Detecting Oxygen (O2) and GMA 41B Single Channel Controller...

$2,295.00

2210-030 Dynagard 25 for O2 Stand-alone System with ZD 21 Transmitter for Detecting Oxygen (O2) and GMA 41B Single Channel Controller by GfG

Simple and Effective

The Dynagard 25 Series accurately measures oxygen levels. The unit offers a local display, a horn / strobe, and a linear 4-20 mA output. The Dynagard 25 Series offers a safe and reliable gas warning system.

Alarm Points

Each alarm can be adjusted separately. The alarm point values can be freely adjusted within the detection range of the transmitter. Every alarm point value can be set to over range / under range, latching / non-latching, or resettable / non-resettable.

Alarm Relays

The controller provides four voltage-free relays for the three alarms and one fault warning. The relays may be used to control additional alarm devices like lights or horns. They can even prompt specific counter measures to prevent or limit dangers from gases or vapors.

ZD 21 Zirconia Sensor

The comprehensive electronics allow for easy operation and maintenance and also increase operational safety and accuracy. In less than 2 seconds, the ZD 21 responds to an oxygen deficiency. The sensor has a platinum coating on the inside and outside of the ceramic cylinder. Oxygen is electrochemically reduced at the cathode.

The voltage produced is proportional to the next difference in the partial pressures of oxygen in the reference gas versus the sampled gas. This extremely short response time allows the user the time to take measures to prevent consideable damage.

Features

  • Easy installation
  • Local display and horn / strobe
  • Adjustable alarm points
  • On-board relays for external controls
  • 4-20 mA output
Gases Oxygen(O2)
Detection range 0-25% volume
Detection principle Zirconia oxide
Expected sensor life 5 Years +
Gas supply Diffusion
Humidity 0 to 99 % r.h. non- condensing
Pressure 920 to 1100 hPA
Tempreture 32 to 122 °F / 0 to +55 °C
Power supply 24 VDC wall pack
Weight 6.5 lbs (2.95 kg)
Display 3-digit LED display for linear measurement values, service
1 LED green operational status
1 LED yellow fault
3 LEDs red alarm
Display of maximum / minimum values
Alarms 3 alarm points
User adjustable within the detection range
Alarm Functions Available Over range / under range
Latching / non-latching
Resettable / non-resettable
Hysteresls adjustable
Delay-time 0 to 2 minutes
Alarm thresholds adjustable
Relays 3 alarm points, 1 fault - voltage free factory settings
A1 strobe
A2 open
A3 horn
Fault open
Voltage 250 VAC 50/60 Hz or 250 VDC maximum
Out put Signal Linear 4-20 mA
Horn Low 70 dB at 10 ft. per UL 464
High 83 dB at 10 ft. per UL 464
Strobe Light output on axis (cd)
Low 35
High 68
Dimensions 11x7x2.75 Inches (27.9x17.8x7 cm) (HxWxD)

Questions & Answers