- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
GfG EC 21 Fixed Gas Transmitter with Carbon Monoxide (CO) Sensor, 1 ppm Resolution, 0 - 500 ppm Range - 2104-500F
Item #:
2104-500F
Brand:
GfG
Share this product:
2104-500F EC 21 Fixed Gas Transmitter with Carbon Monoxide (CO) Sensor, 1 ppm Resolution, 0 - 500 ppm Range by GfG
GfG's EC 21 transmitter for detecting toxic gases in ambient air is an inexpensive gas detection solution for use in a wide variety of today's industrial applications.
Simple gas detection
The EC 21 is the simplest way to monitor ambient conditions. Simply attach the EC21 to a GfG controller or a PLC to continuously and efficiently monitor the concentration of hazardous toxic contaminants in the air.
The EC 21 is reverse-wire protected to prevent damage due to incorrect wiring of the device. The power connector hasa "quick disconnect" feature to simplify transmitter installation and service.
Mounting Position of the EC 21
To determine the mounting position of the EC 21 it is important to know and consider the ambient conditions. To achieve the best results, the ventilation conditions and the density of the gases need to be considered.
The EC 21 must be installed so that the gas reaches the sensor even in poorly ventilated areas. If necessary, check the area with a smoke cartridge.
Other influences such as water (rain, dripping or condensation) and dust need to be considered as well.
Features
- Simple to use and extremely economical
- Robust housing is corrosion resistant and dust-tight
- Linear 4 to 20 mA output signal
- 18 - 24 VDC
Detection principle |
Electrochemical (EC) |
Detection method | Diffusion |
Response time | Based on sensor |
Power supply | 18-24 VDC loop power |
Output signal | Linear, 4–20 mA |
Signal connection | 2 shielded wire x 18 AWG <1,000 ft |
Humidity range | 15-99% r.H. non-condensing |
Optional accessories | Calibration Adapter Calibration Kit |
Gas | Detection Range |
Ammonia (NH3) standard temperatures (-4 to +105° F) | 0 to 100 ppm |
Ammonia (NH3) standard temperatures (-4 to +105° F) | 0 to 200 ppm |
Ammonia (NH3) standard temperatures (-4 to +105° F) | 0 to 250 ppm |
Ammonia (NH3) standard temperatures (-4 to +105° F) | 0 to 500 ppm |
Ammonia (NH3) standard temperatures (-4 to +105° F) | 0 to 1,000 ppm |
Ammonia (NH3) freezer temperatures (-40 to +60° F) | 0 to 100 ppm |
Ammonia (NH3) freezer temperatures (-40 to +60° F) | 0 to 200 ppm |
Ammonia (NH3) freezer temperatures (-40 to +60° F) | 0 to 250 ppm |
Ammonia (NH3) freezer temperatures (-40 to +60° F) | 0 to 500 ppm |
Ammonia (NH3) freezer temperatures (-40 to +60° F) | 0 to 1,000 ppm |
Carbon monoxide (CO) | 0 to 500 ppm |
Carbon monoxide (CO) | 0 to 2,000 ppm |