1624-003 G624P Hydrogen Single-Gas Detector (without latching alarm) by GfG

Versatile Combustible Gas Detection

An explosive environment is created when combustible gases or vapors reach levels that are between the lower explosion limit (LEL) and the upper explosion limit (UEL). Methane, for example, has a LEL of 5% volume and UEL of 15% volume. These levels differ depending on which combustible gas is present.

The G600 series audible and visual alarms will be triggered long before an airgas mixture has reached a dangerous concentration. The alarm threshold is usually set to 10% LEL, if not otherwise specified. The measurement principle for combustible gases and vapors in the percent LEL range is detected with a stable catalytic combustion sensor.

Various models of the G600 series use an additional detection principle on the basis of a thermal conductivity sensor. Using this system, combustible gases can be measured in concentrations up to 100% volume. Other models are available with additional ppm or micro range readings. With its internal sampling pump, extremely small amounts of gas can easily be detected from leaks in pipelines, valves and fittings.

G634P

The G634P model is ideal for measuring, detecting and warning of leak warning for combustible gases and vapors.

Features

  • Gas supply companies
  • Chemical industry
  • Laboratories
  • Storage tanks
  • Landfills
  • Solvent working companies
  • Fire departments
  • Civil and underground engineering

…and wherever life and/or property needs to be protected against hazardous combustible gases or vapors.

As the G600 thermal conductivity system shows only a minimal interference by carbon dixide (CO2), this instrument is suitable for direct landfill measurements without filters. The EXOTECTOR’s functional features make it a high performance, reliable gas detector.

Gases Combustible gases and vapors (examples: fuel vapors, natural gas, ethane, butane, methane, propane, hydrogen)
Ranges Micro (10 to 15% LEL)
0-100% LEL or 0 to 100% volume
0-100% volume
Detection principles (sensor) Catalytic combustion (up to LEL)
Thermal conductivity (LEL to 100% volume)
Accuracy 0 to 2% volume = ±0.1% of display
Greater than 2% volume = ±5% of display
(except micro)
Response time T20 5 seconds diffusion, 4 seconds pump
Gas Supply Built-in sampling pump and diffusion
Display Analog scale, 45 mm, range switch
Display of refuse gas CH4 with CO2 e.g. 40% CH4 + 20% CO2;
Reading = approximately 36 to 38% CH4
Temperature range Diffusion mode: -4 to +131°F / -20 to +55°C
Pump mode: -4 to +131°F / -20 to +55°C
Storage temperature -40 to +140°F / -40 to +60°C
Recommended: +41 to +77°F / +5 to +25°
Humidity range Catalytic combustion: 0 to 95% r.h.
Thermal conductivity: 0 to 80% r.h.
Alarm (latching or non-latching) Optical and acoustic alarm for exceeded threshold (fixed); battery alarm for discharged
accumulator; additional battery control switch
Power supply NiCad accumulator 2.0 Ah/3.6 V (approximately 10 hours in diffusion mode)
Pump performance Approximately 15 seconds with 5 minutes sampling line or telescopic probe, 0.5 l/min
Average (0.25 l/min minimum); 10 minute
Sampling line: approximately 20 to 25 second
Ratings and certification (Ex) I s G5 / BVS T6725
Model G 624P: MSHA 2G-3886-0
Additional approvals pending
Function and accuracy test IBK / PFG-Nr. 41301191
Models G615P LEL
G624P LEL, % volume
G634P LEL, % volume, Micro