Honeywell Analytics Vertex Edge Base Rack Enclosure - 1502-2000

Honeywell Analytics Vertex Edge Base Rack Enclosure - 1502-2000

$39,514.00

1502-2000 Vertex Edge Base Rack Enclosure by Honeywell Analytics

Honeywell Vertex™ Edge delivers the reliable performance and versatility of Honeywell Vertex™ — with a lower cost and easier experience. To help you protect people and assets while reducing downtime, Honeywell Vertex™ Edge provides:

  • Authentic Chemcassette® technology for enhanced standard of accuracy: The system detects highly toxic gases quickly and definitively — down to parts per billion (ppb) — as evidenced by a clear, easy-to-view stain on chemically treated tape. This technology, pioneered by Honeywell, delivers low-level gas detection you can count on.
  • Monitoring of more than 40 toxic gases: Start with as few as eight sampling points and add up to 72. Place each point up to 400 feet (120 meters) away for flexible reach.
  • Lower cost of ownership: Get a lower system price than Honeywell Vertex™ — plus Chemcassette® tapes for ammonia, hydrides and mineral acids that last six months instead of the usual three. That means double the usage at a lower operating cost.
  • Smart, intuitive interface for enhanced performance and simple operation: Touchscreen and large icons make it easy to see gas readings, alarms, event logs, real-time trends and overall system status. Minimal training required.

MORE FEATURES & BENEFITS

  • FRONT ACCESS: Easily service the power and data cables with a clear view of the touchscreen and Chemcassette® analyzers. Pullout tray makes it easy to replace and service pumps.
  • SIMPLIFIED OUTPUT: Vertex Edge offers Modbus TCP and Modbus RTU for interfacing to your sites control systems.
  • EASY TUBE MANAGEMENT: Quickly identify sampling tubes for corresponding analyzers, so you can address a fault or install a new point.
  • NO-SCREW SERVICE PANELS: Access the inside of the unit with keylock and latch — no screwdriver needed.
  • SMART REMINDERS: Use the touchscreen to set customized reminders for maintenance tasks; clearly see which elements to service.
  • DURABLE DESIGN: Steel door stands up to traffic, while a splash-proof cap protects the system from overhead liquid exposure.
OVERALL SYSTEM DIMENSION
Size 76" x 24" x 35"
Weight - Full loaded condition ~900lbs (~408kg)
Weight - Empty rack ~655lbs (~297kg)
LOWER DETECTION LIMIT < 37.5 PPM
ANALYZER
Size 22" x 13" x 6"
Weight ≤ 27lbs (12kg)
POWER REQUIREMENTS
Operating voltage 208V~240VAC, 15A
POWER CONSUMPTION
Normal condition 1.1k Watt
Maximum condition ≤ 1.4k Watt
DISPLAY AND OUTPUTS
Visual 15.6" wide screen monitor with capacitive touch interface
Display gas reading, alarm & instrument status real-time base
Provide real-time trend chart and gas event snapshot trend chart
Event logging including maintenance/instrument fault and gas alarm
Multiple searching option for the event
LED indicator: Normal (Green), Alarm 1 (Red), Alarm 2 (Red), Fault (Yellow)
Digital communications TCP/IP and RTU Modbus, OPC (Option)
SECURITY
  Role-based access control Support HTTPS
CERTIFICATION AND SPECIFICATION
  EN 50270 and EN61010-1
UL/IEC 61010-1
RED, FCC for RFID
PERFORMANCE
  Refer to product manual for complete gas list
TRANSPORT SYSTEM
Flow rate 2.1 LPM
Transport time Less than 50 seconds up to 325ft with thin wall tube (0.190"ID)
Sample line tubing 1/4 in. (6.35 mm) O.D. x 0.190in. (4.83 mm) (Thin wall)
Tubing length Up to 400ft (120m) with thin wall
Exhaust line tubing 1/2 in. (12.7 mm) O.D. x 3/8 in. (9.5 mm) I.D. Teflon tubing
Exhaust length Up to 50 ft. (15 m) maximum
OPERATING CONDITIONS
Temperature 59°F to 95°F (15°C to 35°C)
Humidity 20-80% RH
Altitude -1000 ft. (–305 m) to 6000 ft. (1829 m) above sea level
Pollution degree 2
WIRING REQUIREMENT
Power Singe phase power, Minimum 14 AWG
Digital Modbus TCP/IP: CAT5 shielded cable or equivalent (RJ45 connector);
Modbus RTU: 2-wire stranded, shielded cable or equivalent (24-14 AWG)