- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Honeywell Analytics 4 Channel Control Card, Catalytic - 05704-A-0144
Item #:
05704-A-0144
Brand:
Honeywell Analytics
Share this product:
05704-A-0144 4 Channel Control Card, Catalytic by Honeywell Analytics
This provides four channels of control function within a 1" wide package.
- 4-channel operation
- Choice of output options
- Channel displayed: automatic sequencing, highest reading, combination or manual channel display selection options
Back lit LCD | Bar graph + peak reading, digital, alphanumeric |
Front Panel Facilities | CH1-4 LEDs: A1, A2, A3, fault, inhibit per channel Attn LED: card fault, update alarm, alarm test Green LED: power Push button: alarm reset / card select |
Remote Facilities | Inhibit and remote alarm reset |
Supply Voltage | 18V to 32VDC |
Power Consumption | Catalytic: 12.8W 4-20mA: 8.4W |
Display / Alarm Point | Linearity: 2% FSD Repeatability: 2% FSD |
Electronic Drift | Less than 3% / 6 months |
Operating Temperature | -5°C to +55°C |
Storage Temperature | -25°C to +55°C |
Operating Humidity | 20-90% RH (non condensing) |
Dimensions | 3U high x 25mm wide |
Weight | 165g |
Approvals | EN50270 |
Catalytic Bridge Input | |
Drive Method | Constant current |
Current Range | 90mA to 315mA |
Full Scale Range | 15mV to 300mV |
Maximum Line Resistance | 40 ohms at 250mA (including sensor) |
4-20mA Input | |
Loop Powered Voltage | 24V ± 5% isolated |
Sensor Configuration | current source |
Signal Measurement Range | 0 to 25mA |
Maximum Loop Resistance | 500 ohms (including sensor) |
Analogue Output Option | |
Measurement Signal Range | 0 to 20mA or 4-20mA |
Linearity From Input | Better than 2% FSD |
Repeatability From Input | Better than 1% FSD |
Configuration | Isolated current sink or source (with external supply) |