0555 6742 Dew Point Transmitter (1/2 NPT) by Testo

The testo 6740 was especilally developed for trace humidity measurement in compressed or dry air (e. g. granulate dryers). Thanks to a special adjustment, optimum accuracy in the trace humidity range has been achieved. The result of the development of the testo 6740 is a measuring range of -45 °Ctd to +30 °Ctd and excellent accuracy.

For the display of the relevant trace humidity parameters, a freely scalable analog output is available, optionally with a switch contact plug for MAX monitoring. In addition to this, the testo 6740 stands out thanks to its compact and userfriendly design, such as the rotatability of the housing by 350° for the optimum positioning of the display.

  • Measurement of dewpoints in the range from -45 °Ctd to +30 °C
  • Testo polymer humidity sensor with high accuracy and longterm stability
  • Convenient operation via the display menu
  • Analog output 4 to 20 mA (2-wire) and optional alarm plug with 2 integrated switch outputs
  • Compact design with rotatable housing by 350° for optimum positioning of display
  • Display with operating menu (optional)
  • Trace humidity adjustment without reference measuring instrument possible on site with accessory (2-point adjustment device)
Measurement parameters
Dewpoint/trace humidity
Units %RH, °C
Calculated parameters °Ctd, °Ftd, °CtA, °FtA, ppmv, mg/m3, °F
Measuring range -45 °Ctd to +30 °Ctd
Measurement uncertainty ±1 K at 0 °Ctd (+32 °Ftd)
±3 K at -20 °Ctd (-4 °Ftd)
±4 K at -40 °Ctd (-40 °Ftd)
Response time t90 <= 60 sec for change from 13.2 °Ctd to -32.1 °Ctd
t90 <= 17sec for change from -32.2 °Ctd to 13 °Ctd
Sensor Polymer humidity sensor with protocolized trace humidity adjustment at -40 °Ctd (-40 °Ftd)
Normed atmospheric dewpoint
Measuring range -70 to -15 °CtdA (-112 to -5 °FtdA) (at 30 bar rel./ 435 psi)
-54 to +10 °CtdA (-94 to +50 °FtdA) (at 3 bar rel./43.5 psi)
-45 to +30° CtdA (-76 to +86 °FtdA) (at 0 bar rel./0 psi)
Temperature
Measuring range 0 to 50 °C (32 to +122 °F)
Measurement uncertainty ±0.5K (0 to 50 °C/32 to 122 °F)
Sensor NTC
Inputs and outputs
Analog outputs
Current/accuracy 4 to 20 mA (2-wire) / ±40 μA
Measurement rate 2 s
Resolution 12 bit
Load 10 V DC: max. 100 Ω, 30 V DC: 950 Ω
Scaling Freely scalable via display buttons
Switch outputs (opt. alarm plug, 0554 3302)
Contacts 2 closer contacts, pot.-free, max. 30V/0.05A
Switch thresholds Standard 6 °Ctd/12 °Ctd, freely progr. with display
Supply
Voltage supply 24 V AC/V DC (10 to 30 V DC permitted); with alarm plug (0554 3302) 20 to 28 V DC
Current consumption 21 mA (without alarm plug)
65 mA (with alarm plug)
General technical data
Design
Material/colour Plastic, polyacrylamide
Dimensions 199.5 x 37 x 37 mm (with standard plug)
203.5 x 37 x 37 mm (with plug 0554 3302)
Weight Approx. 300 g
Display
Display High intensity 7-segement display
Resolution °C: 0.1
RH: 0.1
°Ctd: 0.1
°Ftd: 0.1
°CtA: 0.1
°FtA: 0.1
ppmv: 1 / 10 / 100 (dep. on meas. value)
mg/m3: 1 / 10 / 100 (dep. on meas. value)
°F: 0.1
Rotatability (display positioning) 350° around housing axis
Installation
Thread / process connection G1/2 thread (order code 01) or NPT1/2" thread (order code A 02)
Miscellaneous
Protection class IP65 (with plug attached and wire connected)
EMC According to guideline 89/336 EEC
Operating conditions
Operating temperature (housing) -20 to +70 °C (+4 to +158 °F)
Storage temperature -40 to +80 °C (-40 to +176 °F)
Process pressure max. 50 bar (725 psi)