- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Bacharach ECA 450 NOx & SOx kit, includes O2, CO/H2-compensated (0-4,000 ppm), NO, NO2, SO2 and compact sample conditioner with 12 in. sample probe and 15 ft. sample line/hose assembly - 0024-8401
Item #:
0024-8401
Brand:
Bacharach
Share this product:
0024-8401 ECA 450 NOx & SOx kit, includes O2, CO/H2-compensated (0-4,000 ppm), NO, NO2, SO2 and compact sample conditioner with 12 in. sample probe and 15 ft. sample line/hose assembly by Bacharach
MSA Bacharach's ECA 450 is an industrial grade analyzer ideal for professionals concerned about combustion efficiency, environmental compliance, or both. Accommodating up to seven sensors, simultaneous measurements and calculated parameters are evaluated to ensure that industrial equipment is meeting environmental regulations while burning safely and efficiently.
The ECA 450 is designed for on-demand or semi-continuous sampling of industrial furnaces, boilers and other industrial combustion equipment. It complies with regulations such as U.S. EPA test methods, EN 50379, CTM-030 and state/local protocols including SCAQMD.
Note: The ECA 450 calculates CO2 value based upon other measured values during the combustion process. It does not measure CO2 directly.
Features
- Measures up to 7 gases simultaneously (minimum O2 and CO), including NOx, SOx and combustibles
- Sensors are easily replaced or upgraded in the field
- Rugged suitcase design with large, easy-to-read display
- Built-in printer for instant traceability and record-keeping
Measeurement | Description |
O2 | 0.1 to 20.9% |
CO (H2 COMPENSATED) | 0 to 4,999 ppm |
CO (HIGH RANGE) | 4,001 to 80,000 ppm |
NO | 0 to 3,500 ppm |
NO2 | 0 to 500 ppm |
SO2 | 0 to 4,000 ppm |
COMBUSTIBLES | 0 to 5.00% (application dependent) |
STACK TEMPERATURE | -4 to 2,400° F (-20 to 1,215° C) |
PRIMARY / AMBIENT TEMPERATURE | -4 to 999° F (-20 to 999° C) |
PRESSURE / DRAFT | -27.7 to 27.7 inwc |