Modern Water 2, 4-D 100 Tube Kit - A00082

Item #:
A00082
Brand:
Modern Water
Modern Water 2, 4-D 100 Tube Kit - A00082
$1,113.00
Qty
Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Modern Water 2, 4-D 100 Tube Kit - A00082

Modern Water 2, 4-D 100 Tube Kit - A00082

$1,113.00

A00082 2, 4-D 100 Tube Kit by Modern Water

RaPID Assay® is a rapid field or laboratory enzyme immunoassay method for the analysis of soil and water for remediation, assessment, and industrial testing.

Features:

  • Rapid field testing procedure for analysis of soil and water samples
  • Quantitative data results with excellent analytical precision
  • Test up to 50 samples at one time
  • Results available in approximately 60 minutes
  • Training available
  • Magnetic particle immunoassay
  • EPA SW-846 method #4015

Test result type

  • Quantitative, semi-quantitative or qualitative

Samples per kit

  • 100 test kit (tests up to 80+ samples)

Assay range

  • Soil: 0.15 ppm to 7.5 ppm as 2, 4-D
  • Water: 1.0 to 50.0 ppb as 2, 4-D
  • Range can be extended with additional dilutions

Sample preparation

  • Soil samples require prior extraction as indicated in the application procedure

Sampling time

  • A 16 hour extraction time is recommended for soil Method 4015

Specificity

The 2, 4D RaPID Assay immunoassay test does not differentiate between 2,4-D and other chlorophenoxy acids. The table below shows compounds at the limit of quantitation (LOQ) -an approximate concentration required to yield a positive result at the lowest standard. The IC50 is the concentration required to inhibit one-half of the color produced by the negative control. It is also used to calculate cross-reactivity values to similar compounds.

Basic Test Procedure

  • Add standards, prepared sample, enzyme conjugate, and antibody coupled magnetic particles.Vortex.
  • Incubate for 30 minutes
  • Using the magnetic separator, decant and wash
  • Add colour solution, incubate 20 minutes
  • Stop the reaction and read colour at 450 nm
  • Quantitative results and QC parameters are calculated and printed automatically using the RPA-1I spectrophotometer

Test kit components

  • Antibody coated magnetic particles for analysis of 100 test tubes
  • Zero standard, wash, enzyme conjugate, colour development and stop reagents
  • Standards for 1, 10 and 50 ppb as 2, 4-D
  • Disposable test tubes
  • Test kit instructions

Storage & precautions

  • Shelf life is typically one year from date of manufacture, with specific kit expiration date information provided on product packaging
  • Reagents must be stored at 39° to 46°F (4° to 8°C) when not in use
  • Store at ambient temperature 64° to 81°F (18° to 27°C) is acceptable for day of use for up to 8 hours
  • Kits must be brought to 64° to 81°F (18° to 27°C) before use
  • Do not expose colour solution to direct sunlight

Required test materials

  • 2, 4-D 100 tube kit (A00082)
  • 2, 4-D sample diluent (A00079)

Required test equipment

  • RaPID Assay accessory kit (6050100 (P)/6997010 (R)) which contains: RPAI1 analyser (6000081), Magnetic separation rack (A00004), Repeator pipet (A00008), Adjustable volume pipet (A00176), Vortex mixer (A00014), Portable balance (A00131), Digital timer (A00015)
  • Repeator pipet tips (12.5 mL) (A00013)
  • Adjustable pipet tips

Other recommended materials

  • Latex gloves
  • Liquid and solid waste containers
  • Calculator
  • Absorbant paper for blotting
  • Marking pen
2, 4-D IN WATER (PPB)
Contaminant LOQ IC50
2, 4-D 1.0 15.0
2, 4-D Propylene Glycol Ester 0.053 0.79
2, 4-D Ethyl Ester 0.055 0.82
2, 4-D Isopropyl Ester 0.096 1.44
2, 4-D Methyl Ester >0.12 1.64
2, 4-D Butyl Ester >0.19 2.40
2, 4-D Sec-Butyl Ester 0.147 2.20
2, 4-D Butoxyethyl Ester 0.207 3.10
2, 4-D Butoxy-Propylene Ester 2.07 31.1
2, 4-D Isooctyl Ester >2.08 30.0
2, 4, 5-T 12.7 190
2, 4-DB 9.27 139
MCPA 10.6 159
MCPB 98 1470
4-Chlorophenoxy acetic acid 81.3 1220
Dichloroprop 500 7500
Silvex (2, 4, 5-TP) >167 2060
Dichlorophenol 238 3570
Triclopyr >830 >10,000

Datasheets & User Manuals

Questions & Answers


1 Question & 1 Answer
Orlando Marquez
from Miami, FL asked:
June 8, 2021
Hello,

Does this kit works to detect 2,4-D in agro products (cocoa beans) through Hydrolysis? 


Thank you

Orlando


1 Answer
Thank you for the opportunity to assist. That could certainly work, but we don’t have any information surrounding what detection would be and how it would need to be processed. We do have information where customers have used some of our RaPID Assay kits in corn, grapes, celery, etc
Submitted by: Ferdinand Sangalang on June 8, 2021