- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
GfG ZD 22 Fixed Gas Transmitter with Oxygen (O2) MK 410-1, 0 - 96% vol., Display / 4-20 mA - ZD22-704-D
Item #:
ZD22-704-D
Brand:
GfG
Share this product:
ZD22-704-D ZD 22 Fixed Gas Transmitter with Oxygen (O2) MK 410-1, 0 - 96% vol., Display / 4-20 mA by GfG
Superior technology
The ZD 22 Transmitter is specifically designed for long-term monitoring of oxygen concentrations. The integrated amperometric oxygen sensor is based on an electrochemical oxygen pumping cell made of zirconium dioxide. It is characterized by its robustness, a very high life expectancy and its outstanding long-term stability. The integrated thermostatic control of the sensor element achieves accurate measuring results in the entire temperature range, regardless of the operating temperature. It can also be permanently used in environments with high concentrations of CO2 or in dry atmosphere. Special equipment is available to protect the transmitter when used in harsh environments.
Signal processing
The protective casing (IP 54) of the ZD 22 Transmitter contains the complete signal processing electronics and the failsafe routing of the measurement signal for the measuring computer, with extensive self-monitoring. The embedded software linearises the measuring signal and compensates for the effects of temperature. As a result, correct readings are transmitted even with weather related fluctuations in temperature. In addition, the transmitter can be connected to a gas measurement computer for the option of transmitting service, maintenance, and error messages.
Universal signal transmission
The ZD 22 Transmitter transmits the signals either using an analog (0.2 1mA / 4-20 mA) current interface or a digital (RS485) Modbus interface. This permits the universal use of the trasmitters in combination with GfG gas measurement computers and thus connection to a safety system, so that you and your systems will benefit from the best possible protection.
There are a variety of applications for the ZD 22 in regard to sensors, status LEDs and optional analog or digital interface, "Zero" key to calibrate the zero point, test socket and a potentiometer for the calibration of the sensor.
Weather protection
A weatherproof housing not only protects transmitters against exposure to wind and weather, but also against contamination and excessive temperatures caused by direct sunlight.
Optional colored graphic display
The clear graphic display of the ZD 22 is self explanatory and allows you to read the current status and other important information with ease. The display enables you to navigate effortlessly through the unit’s concise menu and to change settings or even calibrate, depending on your user authorization. In the event of an alarm the display changes color from green to red. Two LEDs indicate the status.
Operation buttons
The buttons on the transmitter allow the unit to be calibrated and settings to be adjusted through the menu as needed.
Calibration adapter
In order to perform a calibration, a calibration adapter is used on the transmitter, which ensures a uniform and secure supply of gas.
Easy and convenient service
GfG offers full after-the-sale commissioning and field service support.
- Long service life of the sensors
- Extremely fast response time: t90 < 5 sec.
- Reduced pressure, humidity, or temperature influence
- No damage due to CO2
- Cost effective single-man adjustment
- Affordable operation costs
Gases | Oxygen (O2) |
Measuring Range | 0.2 % vol. 0.25 % vol. |
Measuring Accuracy | +/- 0.1 % vol. (repeatable) |
Detection Method | Power Limited sensor based on zirconium dioxide |
Measurement Principle | Zirconium Dioxide |
Gas Supply | Diffusion Flow rate with calibration adapter |
Response Time t90 | <5 seconds (0 at 25 % vol. O2) |
Expected Sensor Life | >5 years (depending on the sensor and environmental conditions) |
Ambient Temperature | -4 °F to +122 °F/ -20 °C to +50 °C |
Humidity | 5 to 90 % r.h. non-condensing |
Ambient Pressure | 80-120 kPa |
Output Signal | 0.2-1 mA / 4-20 mA / RS485 (Modbus) |
Power Supply | 15 - 30 V DC |
Available Configurations | Display Blind (without display) |
Housing | Material: Plastic, IP 54 |
Weight | 6 oz. or 8 oz. / 175 g or 220 g (display version) |
Dimensions | 3.8 x 5.5 x 2 in. / 96 x 140 x 49 mm (W x H x D) |
Housing Protection | IP 54 |