- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Oakton Eutech pH 800 1/4-DIN On/Off Controller, 110 VAC, with NIST Traceable Certificate of Calibration - WD-56705-17
Item #:
WD-56705-17
Brand:
Oakton Instruments
Share this product:
WD-56705-17 Eutech pH 800 1/4-DIN On/Off Controller, 110 VAC, with NIST Traceable Certificate of Calibration by Oakton
Economical, reliable on/off control even in high electrical noise applications!
The pH 800 controller provides ±0.01 pH accuracy for reliable, easy-to-use on/off control of your pH and mV process. Two separately programmable relays are ideal for acid feed/base feed applications. Use the isolated 4-20 mA output to send data to your recorder or data acquisition system for hard copy reports.
Customize your controller to fit your exact application! This unit is selectable for pH or ORP (mV) control and manual or automatic temperature compensation. The 1/4 DIN size fits into standard panel cutouts. IP54 rated front panel keypad is weather resistant. Mounting hardware included.
- Large dual LCD shows pH (or ORP) and temperature simultaneously
- Two set point, two SPDT relay for on/off control
- Symmetrical mode operation eliminates electrical noise
- HOLD feature deactivates relays on contact closure; ideal for float switches or dual controller applications
- 0 to 2000 second time delay adjustment on all relays
- Separately adjustable high and low set point hysteresis bands prevent rapid contact switching near set points
- Push button two-point calibration and electrode offset adjustment
- Protected against electromagnetic interference
- LED indicators signal control activities to monitor controller status
- Battery back-up of memory maintains set-up if power fails
Measures | pH, mV, °C |
pH Range | 0.00 to 14.00 pH |
pH Resolution | 0.01 pH |
pH Accuracy | ±0.01 pH |
pH Calibration | one or two points (select from pH 1.00, 4.01, 6.86, 7.00, 9.00, 9.18, or 10.00) |
mV Range | ±1000 mV |
mV Resolution | 1 mV |
mV Accuracy | ±1 mV |
mV Calibration | mV offset |
Temperature Range | -9.9 to 125°C |
Temperature Resolution | 0.1°C |
Temperature Accuracy | ±0.1°C |
Temperature Calibration | offset up to ±5°C |
Control type | on/off |
Number of inputs | one |
Number of set points | two (high and low) |
Separate alarm relay | no |
Output Control | 2 SPDT relays, 6 A at 110 VAC, 250 VAC maximum |
Output Current | isolated 4-20 mA, 600 W maximum load |
Hysteresis | 0.1 to 1.0 pH, 10 to 100 mV, or 1 to 10% |
Relay delay | selectable, 0 to 2000 seconds |
Input impedance | 10^6 M |
Electrical isolation | yes, galvanically |
Temperature Sensor | 100 or 1000 Pt RTD |
Temperature Compensation | Automatic or manual from -9.9 to 125°C |
Password protection | two level password |
Display | dual line LCD, 4-digit upper and 3 1/2 digit lower |
Operating Temperature | -10 to 60°C |
Housing | 1/4 DIN |
Dimensions | 3.8" x 3.8" x 6.9" (9.6 x 9.6 x 17.5 cm) |
Shipping weight | 2.5 lbs (1.2 kg) |