- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Oakton Eutech DO 500 1/4-DIN Dissolved Oxygen Transmitter with Display - WD-35151-10
Item #:
WD-35151-10
Brand:
Oakton Instruments
Share this product:
WD-35151-10 Eutech DO 500 1/4-DIN Dissolved Oxygen Transmitter with Display by Oakton
Economical, industrial, low-voltage transmitter with display
This transmitter provides local monitoring of oxygen concentrations, temperature, and also provides a 4 to 20 mA output signal to a centralized control, datalogging, or recording system. The IP65-rated housing can be easily mounted on plates, poles,or walls. Requires a 12 to 24 VDC power input—ideal for industrial settings such as chemical processing, food processing, galvanic decontamination, and clean or wastewater control.
Setup and calibration are easy with the large LCD and front-panel push buttons that guide you through the steps. Transmitter can be programmed for manual or automatic temperature compensation (ATC) with independent settings for process and calibration temperatures. Unique, selectable hold function freezes output current at 22 mA when programming or performing calibrations. Out-of-range concentrations can also be indicated by 3.8 mA output when selected. Order dissolved oxygen electrode separately.
- Measures DO in mg/L, ppm, or % saturation and displays temperature
- One- or two point-calibration
- Manual salinity and barometric pressure compensation
Range | 0 to 199.9%; 0.0 to 19.99 mg/L (ppm) |
Accuracy | 1.5% FS |
Calibration | one point at 100% saturation |
ATC | manual or automatic, from 0 to 50°C |
Input | galvanic dissolved oxygen sensor |
Output | 4 to 20 mA |
Operating Voltage | 12 VDC to 24 VDC |
Load | 100 max load for 12 VDC and 600 ma |
Dimensions | 3-3/4" x 3-3/4" x 2-5/8" (1/4 DIN) (9.5 x 9.5 x 6.7 cm) |
Shipping weight | 2 lbs (0.9 kg) |
Temperature Resolution | 0.1°C (0.1°F) |
Conductivity Accuracy | ±1% full-scale |
Ion Accuracy | ±0.5% full-scale (monovalent); ±1% full-scale (divalent) |
TDS Accuracy | ±1% full-scale |
DO Accuracy | ±0.2 mg/L; ±2% |
Temperature Accuracy | ±0.5°C (±0.9°F) |
Conductivity Calibration | Manual up to 5 points (1 per range); automatic up to 4 points (84.0 μS/cm, 1413 μS/cm, 12.88 mS/cm, 111.8 mS/cm) |
DO Calibration | Two points; 100% and 0% |
Temperature Calibration | Offset 0.1°C (0.1°F) increments |
TDS factor | 0.40 to 1.00 |
Cell constant | 0.100 to 10.000 |
DO salinity correction | Range: 0.0 to 50.0 ppt Resolution: 0.1 ppt |
DO pressure correction | Range: 500 to 1499 mm Hg, 66.6 to 199.9 kPa Resolution: 1 mm Hg, 0.1 kPa |
Memory | up to 500 sets with GLP date and time |
Output | infrared, IrDA |
Real-time clock | time-and-date stamp on calibration and stored data |
Temperature normalization | 15 or 30°C |
Temperature coefficient | linear or pure |
Temperature compensation | automatic or manual (selectable), from 0 to 100°C |
Ambient operating temperature | 0 to 50°C (32 to 122°F) |
Power | four 1.5 V AA batteries (included) or optional universal AC adapter, up to 200 hours continuous use |
Dimensions | Meter: 7.50"L x 3.75"W x 2.25"H (19 x 9.5 x 5.7 cm) Boxed: 9.13"L x 9.13"W x 2.75"H (23 x 23 x 7 cm) |
Weight | Meter: 1 lb (0.5 kg) Boxed: 2 lb (0.9 kg) |