- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Oakton Traceable® One-Shot™ Conductivity and TDS Standard, 1413 µS; 6 x 100 mL Vials - WD-00652-68
Item #:
WD-00652-68
Brand:
Oakton Instruments
Share this product:
WD-00652-68 Traceable® One-Shot™ Conductivity and TDS Standard, 1413 μS; 6 x 100 mL Vials by Oakton
- Oakton® Traceable® conductivity and TDS standards have detailed labels: KCl, NaCl, and 442 conversions, temperature corrections, and certified values referenced to 25°C-convenient!!
- Average accuracy at 25°C is ±0.25 microsiemens for 1, 5, 10 microsiemen (μS) solutions, or ±0.25% for all other solutions. The tested uncertainty is shown on the certificate, whichever is greater
- Conductivity options range from 1 to 200,000 μS/cm
- Individually-tested solutions are certified by the bottle - each bottle is analyzed for the best accuracy
METHODS SUPPORTED
Certified reference material meets test requirements for Federal, State, and local agencies, CAP, ASTM, NCCLS, CLSI, ACS, CLIA, AOAC, EPA, APHA, AWWA, WEF, USGS, USP, and ISO. Traceable® Conductivity Standards complies with and is essential for use in these official methods: AOAC 973.40, EPA 120.1, Standard Method 2510 (APHA, AWWA, WEF), ISO 7888, DIN 38404, ASTM D1125, USGS I-1780, USP 645, and for A2LA/NVLAP accreditations/ISO 9000 certifications. Material may be used to calibrate all conductivity meters and to determine all conductivity cell constants.
A2LA ACCREDITATION ISO/IEC 17025:2005 (1750.01)
To assure accuracy an individually serial-numbered Traceable® Certificate is supplied to indicate traceability to standards provided by NIST (National Institute of Standards and Technology) and/or a National Standards Laboratory. A2LA accredited certification provides the highest achievable level of quality assurance, documentation, and accuracy. Conductivity Standards are produced in an A2LA accredited ISO/IEC 17025:2005 (1750.01) calibration laboratory. Additional certifications include ISO 31 (certificate content) and ISO 35 (statistical analysis), plus ISO 9001 (certified quality manufacturer).
- All Oakton® Traceable® conductivity standards are NIST-traceable reference materials
- Supplied with a calibration report from an ISO 17034 and ISO 17025 accredited laboratory
- These standard solutions let you calibrate conductivity instruments to ensure accuracy
- If unopened, shelf life is one year; once opened, shelf life will vary by solution value
- Use when readings are expected to be around 1413 μS/cm
INCLUDES
temperature compensation chart, TDS conversion chart, and NIST-traceable calibration certificate with data.
Conductivity Value (μS) | 1413 |
Conductivity Value (mS) | 1.413 |
Conductivity Value | 1413 μS/cm |
TDS Value (ppm) | 933 |
Volume (mL) | 100 |
Volume (oz) | 3.4 |
Volume | 6 x 100 mL vials |
Description | Oakton Traceable® One-Shot™ Conductivity and TDS Standard, 1413 μS; 6 x 100 mL Vials |