- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Honeywell Analytics Floor Standing Cabinet with Front Access 2000Hx800Wx600D includes Controller with HMI, PCBs, SD Card, Redundant Control Centre Board, Modbus® Interface Board, with 100mm plinth, w/o ventilation, w/o power distribution - TPPR-HF-FS-LRMHPX
Item #:
TPPR-HF-FS-LRMHPX
Brand:
Honeywell Analytics
Share this product:
TPPR-HF-FS-LRMHPX Floor Standing Cabinet with Front Access 2000Hx800Wx600D includes Controller with HMI, PCBs, SD Card, Redundant Control Centre Board, Modbus® Interface Board, with 100mm plinth, w/o ventilation, w/o power distribution by Honeywell Analytics
Honeywell's Touchpoint Pro makes gas control system design, installation, configuration and operation simple. Touchpoint Pro uses a 'building block' approach, providing unrivalled flexibility. The building block approach employed by Touchpoint Pro delivers real value by being able to adapt to each unique system requirement. Ease of use and intuitive configuration ensures that installation, set-up and ongoing maintenance costs are reduced, providing a 'no compromise' solution designed to reduce the cost of on-site safety.
Flexible architecture
Touchpoint Pro has been designed to deliver flexibility, allowing the system to be freely configured to meet customers' varying needs. Touchpoint Pro's modularity means that any system topology can be built, including centralised, distributed I/Os, or a mix of both.
24/7 visibility of system status
Touchpoint Pro's central controller has a Webserver interface, which can be accessed when it is connected to a network, allowing users to remotely view status and event history, and acknowledge, reset or inhibit channels. This feature offers the possibility of system monitoring and data analysis from a remote location using multiple devices including tablets, smart phones and remote computers.
Simple installation and maintenance
Using a simple building block technique to create your system, Touchpoint Pro offers multiple features that simplifies installation, setup and ongoing maintenance. A key feature to this is the preloaded sensor catalogue, which contains a complete listing of all Honeywell Analytics' gas sensors, each with a full default configuration setting. A user can choose to configure input channel settings from the sensor catalogue, resulting in a quick and simple three step configuration process. The rest of the configuration will be loaded automatically.
Wide selection of inputs/outputs accepted
The Touchpoint Pro Input/Output plug-in modules can be combined up to a maximum of 16 input modules (64 channels) and 32 output modules (128 channels). Modules can be located in any Touchpoint Pro enclosure and power distribution is via the communication/power Rail. Touchpoint Pro accepts analogue, digital and relay modules making it one of the most flexible controllers available.
Intuitive user interface
The heart of the Touchpoint Pro is the central controller, which includes the user interface. The user interface features a full colour LCD touch screen, and provides engineers with an intuitive solution to system set-up and deployment. Easily accessible icons, supported by drop-down menus ensure that even the most complex of system configurations can be commissioned with efficiency.
Aside from ease of use, Touchpoint Pro's user interface also includes some valuable aspects that help engineers save time, whilst setting up and commissioning a system.
Features & Benefits
- Webserver ensures 24/7 system status visibility for constant safety
- Flexible system architecture to meet specific site needs
- Easily accessible system status that can be seen at a glance
Quick Specs
- Up to 64 channels of detection and 128 output channels
- Digital and analogue inputs available
- Mulitple mounting possibilities
- Touchscreen user interface
ENCLOSURE | |
WALL MOUNT CONTROLLER ENCLOSURE | |
Dimensions (H x W x D) | 600 mm x 600 mm x 300 mm (Mild Steel) 800 mm x 600 mm x 300 mm (Mild Steel) 1200 mm x 600 mm x 300 mm (Mild Steel) |
WALL MOUNT REMOTE UNIT ENCLOSURE | |
Dimensions (H x W x D) | 600 mm x 600 mm x 300 mm (Mild Steel) 800 mm x 600 mm x 300 mm (Mild Steel) |
19" 5U RACK UNIT | |
Dimensions (H x W x D) | 483 mm x 222 mm x 110 mm (Mild Steel) |
FLOOR STANDING CABINETS (FRONT OR REAR ACCESS) | |
Dimensions (H x W x D) | 2000 mm x 800 mm x 600 mm (Mild Steel) |
CONTROL MODULE AND USER INTERFACE | |
LCD Touch Screen | 5.7" TFT Colour LCD with LED Backlight (resistive touch screen) 320 x 240 pixels (QVGA) Resolution Active area 115.2 mm(H) x 86.4 mm(V) |
Front Panel Dimension | 483 mm x 222 mm |
Operating Temperature | -20°C to +55°C |
Storage Temperature | -20°C to +55°C |
Operating Humidity | 10% to 90% RH (non-condensing) |
INPUT SUPPLY | |
Input Voltage | 18-32 Vdc (24 Vdc nominal) |
Voltage Ripple | 50 mVp-p (maximum) |
CONTROLS AND INDICATORS | |
Front Panel LED | Green Power LED Red Alarm LED Yellow Fault LED Yellow Inhibit LED |
Front Panel Buttons | Alarm Accept Push Button, Alarm Reset Push Button; Alarm Buzzer |
Relay Outputs | 2 System State Relays |
Redundancy | Redundant Control Centre Board (CCB) Ring Network |
EXTERNAL COMMUNICATION | |
Interfaces | Redundant RS485 Modbus RTU interface Ethernet |
INPUT/ OUTPUT MODULES | |
COMMON SPECIFICATIONS | |
Dimensions (H x W x D) | 35.0 mm x 99.5 mm x 114.5 mm |
Power Supply | 18-32 Vdc (24 Vdc nominal) |
DIN rail compatibility | TS-35 / 15 |
Operating Temperature Range | -40°C to 55°C |
Operating Humidity Range | 10 to 90% RH (non-condensing) |
Inputs | Up to 16 Input Modules (64 Input channels) per system Analogue Input Module 4-20 mA; 4-channels for 2 or 3 wire 20 mA detector signals Analogue Input Module mV-Bridge; 4-channels for mV-Bridge signals Digital Input Module; 4-channels for switched input devices |
Outputs | Up to 32 Output Modules (128 Output channels) per system Relay Output Module; 4-channels incorporating 4 single pole change over (SPCO) relays; Analog Output Module 4-20 mA |
COMMUNICATION / POWER RAIL | |
Description | 5, 7, 9, or 10-way Communication / Power Rail consists of 1 DIN Rail, 1 Ring Coupling Module (RCM) and 5, 7, 9, or 10-way backplanes |
Power Supply | Operating voltage range - 18 Vdc to 32 Vdc (double-check) |
Power Supply mounted on Din-Rail | 120 W 24 Vdc, 240 W 24 Vdc, 480 W 24 Vdc, Power Supply Redundancy Module (RDN Module), Uninterruptible Power Supply Module (UPS) |
BACK-UP BATTERY | |
Description | 24 V sealed lead acid battery, 12 Ah or 27 Ah options |
Electrical Connection | 2 x 12 Vdc batteries in series |
Dimensions (H x W x D) | 300 mm x 395 mm x 215 mm |
Weight | 12 Ah version: 15.7 kg 27 Ah version: 25 kg |
APPROVALS | |
Compliance | Compliance with EMC/RFI (EN 50270:2006) and LVD (EN 61010-1:2010) CSA-C22.2 No. 61010-1-04, UL Std. No. 61010-1 (2nd Edition) |
Advanced requirements | ATEX Performance Approvals - EN 50271:2010; EN 60079-29-1; EN 45544-1 /-2 /-3; EN 50104:2010 C22.2 No. 152-M1984, FM Std. 6310 and 6320 |
Highest level of safety | IEC/EN 61508 and EN 50402 SIL2 certification |