- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Specifications
Specifications
Instrument dimensions: 13.1 x 7.0 x 5.2 cm (5.1 x 2.8 x 2.0 in.)
Weight: 328 g (11.6 oz.)
Operating temperature: -20°C to +50°C (-4°F to +122°F)
Storage temperature: -40°C to +60°C (-40°F to +140°F)
Operating humidity: 10% to 100% relative humidity (non-condensing)
Dust and moisture ingress: IP66/67
Alarm setpoints: May vary by region and are user-defined
Detection range:
H2S: 0 – 200 ppm (1 ppm increments)
CO: 0 – 1000 ppm (1 ppm increments)
O2: 0 – 30.0% vol. (0.1% vol. increments)
LEL (combustible): 0 – 100% LEL (1% LEL increments) or
0 – 5.0% v/v methane
Sensor type:
H2S, CO, O2: Single plug-in electrochemical cell
LEL (combustibles): Plug-in catalytic bead
O2 measuring principle: Capillary controlled concentration sensor
Alarm conditions: TWA alarm, STEL alarm, low alarm, high alarm, multi-gas alarm, over limit (OL) alarm, low battery alarm, confidence beep, automatic deactivation alarm, pump alarm
Audible alarm: 95 dB+ at 30 cm variable pulsed beeper with full battery charge
Visual alarm: Red light-emitting diodes (LEDs)
Display: Alphanumeric liquid crystal display (LCD)
Backlight: Activates upon startup and when the pushbutton is pressed; deactivates after 10 seconds. Activates during an alarm condition and remains lit until alarm ceases
Self-test: Initiated during activation, self-test runs continuously while detector is operational
Calibration: Automatic zero and automatic span
User field options: Startup message, lockout on self-test error, safe mode, confidence beep, latching alarm, force calibration, cal IR lock, force bump, location logging, force block test, set datalog interval, set confidence interval, language selection.
Sensor options: Sensor enable/disable, set span concentration values, set calibration interval, set bump interval, set alarm setpoints, set STEL interval, set TWA period, auto zero at startup enable/disable, 5% overspan, low alarm acknowledge, oxygen measurement, and combustible gas measurement
Maximum hose length for sampling: 75 ft (22 m)
Maximum hose length for calibration: 3 ft (0.9 m)
Battery operating time: One rechargeable lithium polymer battery at 20°C provides 13 hours operating runtime
Year of manufacture: The detector’s year of manufacture is determined
from the serial number. The first and second number after the first two
letters determines the year of manufacture.
Example: MA110-001000 = 2010 year of manufacture
Approved battery for GasAlertMax XT II product: Lithium-ion polymer (MA-BAT01) as per standards EN50020, UL913, CSA C22.2 No. 157
Rechargeable battery:Lithium Polymer
(MX-BAT01): -20°C ≤ Ta ≤ +50°C
Temperature CodeT4
Battery charger: GasAlertMax XT II Charging Adapter
First-time charge: 6 hours
Normal charge: 6 hours
Warranty: 2 years including sensors
Approvals:Approved by CSA to both U.S. and Canadian Standards CAN/CSA C22.2 No. 157 and C22.2 152 ANS/UL – 913 and ANSI/ISA – S12.13 Part 1
CSA Class 1, Division 1, Group A, B, C, and D
ATEX CE 0539 II 1 G Ga Ex ia IIC T4
KEMA 08 ATEX 0001
IECEx Ex ia IIC T4 Ga
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and ICES-003 Canadian EMI requirements. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
General Datalogger Specifications
Storage: 375 hours at 15-second intervals (75% redundancy)
Memory type: Wraparound memory ensures most recent data is always saved
Sample rate: One reading every 1-120 seconds
Data recorded: All sensor readings, all alarm conditions, calibrations, event flags, battery status, sensor status, pump status, confidence beep activation, and detector status along with the time and date for each reading and unit serial number
Operation: Requires no user intervention (automatic)
Compatible with: Desktop PC computer or laptop
Operating system: Windows XP and Windows Vista
Download via: IR device (IR Link adapter or MicroDock II Base Station)
Software required: Fleet Manager II and Microsoft Excel