- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Specifications
Specifications
XT: 11.25 x 6.00 x 2.89 cm (4.4 x 2.4 x 1.1 in.)
XL-X3: 11.25 x 6.00 x 3.22 cm (4.4 x 2.4 x 1.2 in.)
Weight:
XT: 170 g (6.0 oz.)
XL: 190 g (6.7 oz.)
X3: 179 g (6.3 oz.)
Operating temperature: -4°F to +122°F (-20°C to +50°C) ()
Storage temperature: -40°F to +122°F (-40°C to +50°C)
Operating humidity: 0% to 95% relative humidity (non-condensing)
Dust and moisture ingress: IP66/67
Alarm setpoints: May vary by region and are user defined. All setpoints automatically display during the startup self-test
Detection range::
H2S: 0 – 100 ppm (1 / 0.1 ppm increments)
CO: 0 – 500 ppm (1 ppm increments)
O2: 0 – 30.0% vol. (0.1% vol. increments)
Combustible (LEL): 0% to 100% LEL (1% LEL increments) or 0.0% to
5.0% v/v methane
Alarm conditions:TWA alarm, STEL alarm, low alarm, high alarm, multi-gas alarm, over limit (OL) alarm, low battery alarm, confidence beep, automatic deactivation alarm
Audible alarm: 95 dB at 30 cm (1 ft.) (100 dB typical) variable pulsed beeper
Visual alarm: Red light-emitting diodes (LED)
Display: Alphanumeric liquid crystal display (LCD)
Backlight: Activates when the pushbutton is pressed and deactivates after 5 seconds; also activates during an alarm condition
Self-test: Initiated upon activation
Calibration: Automatic zero and automatic span
Oxygen sensor: Automatic span upon activation (enable/disable)
User field options:Startup message, Confidence Beep, latching alarms, enable/disable safe display mode, oxygen measurement, combustible sensor measurement, sensor disable, define calibration interval, force calibration, calibration lock, force bump, define bump interval, bump due lock, stealth mode, low alarm acknowledge, language selection, enable/disable automatic oxygen calibration, enable/disable auto zero at startup, define alarm setpoints, span concentration values, define STEL calculation period, IntelliFlash, and Confidence Beep and IntelliFlash Interval
Table 17: Battery Operating Time
XL-X3 | XT | |
Typical Battery Life* | 18 hours Recharges in less than 6 hours | 10 hours Recharges in less than 4 hours |
Cold Weather Battery Life** | 12 hours at -4°F / - 20°C | |
*Approximately 20% capacity loss is normal with lithium polymer
batteries after 500 charge cycles. Refer to the Operator’s Manual for
additional information. **Battery is guaranteed to have 12 hour runtime during warranty period under normal operating temperature of -4°F / -20°C to 122°F/50°C. |
1ppm =1 µmol/mol
Manufacture:RAE Systems (Shanghai) Inc
Address: 990 East Huiwang Road, Jiading District, Shanghai, China
201815
Tel: =86-21-69522616
Year of manufacture: The detector’s year of manufacture is determined
from the serial number. The second and third number after the letters
determines the year of manufacture
E.g.: KA410-000001 = 2010 year of manufacture
Approved battery:
Approved batteries for GasAlertMicroClip XT:
Narada NL 503759
Approved batteries for GasAlertMicroClip XL:
Narada NLP883759LT20
Approved batteries for GasAlertMicroClip X3:
Narada NLP883759LT20
Rechargeable batteryLithium polymer
-20°C ≤ Ta ≤ +50°C
Temperature CodeT4
Battery charger:GasAlertMicroClip charging adapter
Warning
Charge only in a safe area that is free of hazardous gas and within temperatures of 32°F to 113°F (0°C to 45°C) First-time charge:
XT: 2-3 hours
XL-X3: 5-6 hours
Normal charge: 6 hours
XT: 2-3 hoursXL-X3: 5-6 hours
Warranty XT-XL: 2 years including sensors
Warranty X3: 3 years including sensors
Guarantee: Battery is guaranteed to have a 12 hour runtime during warranty period under the normal operating temperature of -4°F/-20°C to 122°F/50°C
Approvals:Approved by CSA to both U.S. and Canadian Standards CAN/CSA C22.2 No. 157 and C22.2 152 ANSI/UL – 913 and ANSI/ISA – 12.13.01 Part 1
CSA Class I, Division 1, Group A, B, C, and D
ATEX CE 0539 II 1 G Ex da ia IIC T4 Ga
Sira 13ATEX2330
EN 60079-0, EN 60079-11, EN 60079-26
IECExEx da ia IIC T4 Ga IECEx CSA 05.0015
IEC 60079-0, IEC 60079-11, IEC 60079-26
KTLGasAlertMicroClip XT:12-KB4BO-00531
GasAlertMicroClip XL:14-KB4BO-0659X2
GasAlertMicroClip X3:15-KA4BO-0307X3
Indication Error LEL:± 5% FS: H2S: ± 5x 10-6:CO: ± 10%: O2:± 5% FS
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and ICES-003 Canadian EMI requirements. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
General Datalogger Specifications
Storage: 16 hours at 15-second intervals
Memory type:Wraparound memory ensures most recent data is always saved
Datalog Interval: The default interval is one reading every 15 seconds. The user has the option to change the intervals to rates from 1 to 120 seconds.
Data recorded: All sensor readings, all alarm conditions, calibrations, event flags, battery status, sensor status, confidence beep activation, and detector status with the time and date for each reading and unit serial number
Operation: Requires no user intervention (automatic)
Compatible with: Desktop PC computer or laptop
Operating system:Windows 2000 or higher
Download via:IR device (IR Link adapter or MicroDock II base station)
Software required:
- Fleet Manager II application,
- Microsoft Excel (optional) to create custom reports.