- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Sensorex Stainless Steel Optical DO Probe, 10m, MODBUS output - ODO8000
Item #:
SEN-ODO8000
Brand:
Sensorex
Share this product:
ODO8000 Stainless Steel Optical DO Probe, 10m, MODBUS output by Sensorex
The Lumin-S optical dissolved oxygen sensor delivers reliable DO measurements over a long operating life. There are no membranes to replace, no electrolyte solutions to replenish, and no anodes to clean. Maintaining the sensor is as easy as replacing the optical sensing cap once every 1-2 years, and since all calibration data is stored on the cap, there's no need to calibrate. This dissolved oxygen sensor outputs a Modbus/RS-485 digital signal for easy PLC integration.
Durable and Reliable
- SS316 body option for fresh water
- Titanium body option for salt water
- Optical technology allows for up to 2 years of use without the need for maintenance
Save Time On Set-up
- No calibration required
- Plug and play
Digital Communication
- Open protocol Modbus RS485 Signal
Measurement Principle | Optical measurement via luminescence |
Measurement Ranges | 0.00-20.00 mg/L 0.00-20.00 ppm 0-200% |
Accuracy | ± 0.1 mg/L ± 0.1 ppm ± 1% |
Response Time | 90% in less than 60 seconds |
Measurement Interval | > 5s |
Membrane Cap | Cross Sensitivity: Organic solvents (acetone, toluene, chloroform, methylene chloride); Chlorine gas No Cross Sensitivity: pH 1-14, H2S, CO2, SO2 |
Temperature Compensation | 10K NTC |
Temperature Accuracy | 0.5°C |
Sample Temperature | 0-50°C (32 to 122°F) |
Max Pressure | 5 bar (72.5 PSI) |
Signal Output | Direct MODBUS RS-485 |
Power Supply | 12 Volts (±10%) |
Power Consumption | 1 W |
Dimensions | Diameter: 25 mm (0.98 in) x Length 146 mm (5.75 in) |
Weight | 450g (1lb) for sensor + 3m (10ft) cable |
Material | 316 Stainless Steel(ODO8000), Titanium (ODO9000) |
Protection Rating | IP68 |