- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Sensorex DO Sensor, PPB, 4-20mA, 0-200%, PTFE, Pb - DO7442
Item #:
SEN-DO7442
Brand:
Sensorex
Share this product:
DO7442 DO Sensor, PPB, 4-20mA, 0-200%, PTFE, Pb by Sensorex
Your Dissolved Oxygen (DO) sensor is a galvanic electrochemical device; i.e. it does not require power from your meter or controller to generate its signal. The DO sensor will provide a millivolt signal proportional to the concentration of oxygen in the water (model DO7400, DO7400TC) or 4-20mA current output (models DO7441 and DO7442). The signal output is proportional to ppm of oxygen for probes with millivolt signal output or changes linearly with ppm of oxygen sensors with 4-20mA output. The partial pressure of oxygen, which is directly proportional to the percent saturation of oxygen in a specified sample, can be calculated based upon the oxygen solubility which is a function of temperature, salinity, total atmospheric pressure, etc.
Your Dissolved Oxygen sensor consists of an cathode, anode and an electrolyte separated from your process fluid by an oxygen permeable membrane. The oxygen passing through the membrane reacts at the cathode, giving up electrons, which produces an electrical current.
Sensor Materials | Top and Bottom Cap: Noryl Sensor Body: Delrin Anode: Lead (Pb) Wire Cathode: Silver |
Output at 100% Saturation (mV models) | PTFE Membrane: 31+/-5 mV HDPE Membrane: 48+/-8 mV |
Output at 100% Saturaion (mA models) | D06441: 18-22mA DO6442: 11-13mA |
Output at 0% Saturation (mV models) | PTFE & HDPE Membrane: <1mV |
Output at 0% Saturation (mA models | <4.5mA |
Temperature Range | Max: 50 deg C Min: 0 deg C |
Response Time | PTFE Membrane: 5 minutes from 100% to 0% Oxygen (<1mV or 4.5mA) Water Flow Rate: Min 2 inch/second across membrane. |
Wetted Materials | Body: Noryl Membrane: Teflon or HDPE Cable: 4-conductor, 24AWG, Copper/PVC, polyurethane outer jacket. |
Wiring | DO7400, D07441*, DO7442* Red = + , Black = - DO7400/TC Red = + , Black = - White = Temp, Green = Temp |