- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Crowcon Xgard Type 1 Spare Sensor Module, 0-10ppm, Sulphur Dioxide (CT)
Item #:
S011638-S
Brand:
Crowcon
Share this product:
Xgard Gas Detectors
Crowcon is a global leader in designing and manufacturing gas detection technology and equipment. The company has been in operation for over 40 years and is consistently building upon its products. By integrating modern technology with the demands of the modern workplace, Crowcon has developed a line of gas detection devices and monitors that lead the competition. The Xgard range of gas detectors is a product of Crowcon’s successful integration and technological advancements. With a wide range of sensor types and available accessories, the Xgard series is suitable for all worksites and is customizable enough to fit any needs.
Tough and reliable
The Xgard series of fixed point gas detectors is incredibly durable and reliable. The casings and materials, including weatherproof caps, are designed to protect the equipment from the harshest environments. The detectors are made from a variety of materials depending on the model: glass reinforced nylon, aluminum with polyester coating, and 316 stainless steel.
Variety of sensors
The fixed point gas detector offers a wide range of sensors for to suite almost all applications. The Xgard range of gas detectors is available in three models to meet varying worksite needs: flameproof, intrinsically safe, and safe area formats. Additionally, Xgard offers different types of fixed point gas detectors within these three models:
- Xgard Type 1- Intrinsically safe toxic and oxygen gas detectors
- Xgard Type 2- Flameproof toxic and oxygen gas detectors
- Xgard Type 3- Flameproof flammable gas detector
- Xgard Type 4- Flameproof high temperature flammable gas detector
- Xgard Type 5- Flameproof flammable gas detector with 4-20mA output
- Xgard Type 6- Flameproof thermal conductivity type gas detector
- Xsafe- Safe area flammable gas detector
Cost efficient and highly effective
With quick and easy installation and maintenance, the Xgard series is able to keep costs at a minimum. The replacement sensors, for example, are simple to replace by merely plugging them in. The replacement parts are also readily available and compatible with all Xgard models, thereby reducing the amount of required spare parts that are stored in the facility. Additionally, the sensors have two times the typical life spans of similar sensors in the industry. With a 2 year life span, worksites can expect to cut their sensor replacement costs in half. For worksites that require slightly more customization, Crowcon offers compatible accessories for the Xgard series such as sampling applications, remote gassing applications, spray deflectors, sun shields, weatherproof caps, collector cones, flow adapter, and accessories adapter.
Xgard also has flexible installation options. The unit is designed for either wall or ceiling mounts, and users will not need to purchase additional equipment for mounting. For more complex installation needs, users can purchase accessories.
Specifications
Each model is approximately the same size with dimensions of 6.1 x 6.5 x 4.3 inches and weighing approximately 1 or 2 pounds. The battery type, electrical output, and power requirements vary based on the sensor type. For a complete listing of gas sensors, types, and individual specifications, please see the product specifications listing.
Xgard Model | Type 1 |
Type 2 |
Type 3 |
Type 4 |
Type 5 |
Type 6 |
Junction box material | ATEX Certified: Glass-reinforced nylon or 316 S/S UL Certified: Aluminium or 316 S/S |
Aluminium or 316 Stainless Steel | Aluminium or 316 Stainless Steel | Aluminium or 316 Stainless Steel | Aluminium or 316 Stainless Steel | Aluminium or 316 Stainless Steel |
Dimensions | 156 x 166 x 111mm (6.1 x 6. x 4.3 inches) | 156 x 166 x 111mm (6.1 x 6. x 4.3 inches) | 156 x 166 x 111mm (6.1 x 6. x 4.3 inches) | 95 x 166 x 111mm (7.6 x 6.5 x 4.3 inches) | 156 x 166 x 111mm (6.1 x 6. x 4.3 inches) | 156 x 166 x 111mm (6.1 x 6. x 4.3 inches) |
Weight | Nylon 0.5Kg (1.1lbs) Alloy 1Kg (2.2 lbs) 316 S/S: 3.1kg (6.8 lbs) |
Alloy 1Kg (2.2 lbs) 316 S/S: 3.1kg (6.8 lbs) |
Alloy 1Kg (2.2 lbs) 316 S/S: 3.1kg (6.8 lbs) |
Alloy 1Kg (2.2 lbs) 316 S/S: 3.1kg (6.8 lbs) |
Alloy 1Kg (2.2 lbs) 316 S/S: 3.1kg (6.8 lbs) |
Alloy 1Kg (2.2 lbs) 316 S/S: 3.1kg (6.8 lbs) |
Ingress protection | IP65, IP66 with weatherproof cap | IP65, IP66 with weatherproof cap | IP65, IP66 with weatherproof cap | P54 | IP65, IP66 with weatherproof cap | IP65, IP66 with weatherproof cap |
Cable entries | 1 x M20 or 1/2" NPT on right-side | 1 x M20, 1/2" NPT or 3/4" NPT on right-side | 1 x M20, 1/2" NPT or 3/4" NPT on right-side | 1 x M20, 1/2" NPT or 3/4" NPT on right-side | 1 x M20, 1/2" NPT or 3/4" NPT on right-side | 1 x M20, 1/2" NPT or 3/4" NPT on right-side |
Terminations | 0.5 to 2.5mm2 (20 to 13awg) |
0.5 to 2.5mm2 (20 to 13awg) |
0.5 to 2.5mm2 (20 to 13awg) |
0.5 to 2.5mm2 (20 to 13awg) |
0.5 to 2.5mm2 (20 to 13awg) |
0.5 to 2.5mm2 (20 to 13awg) |
Sensor type | Electrochemical | Electrochemical | Catalytic bead | 316 s/s sensor housing with catalytic beads | Catalytic bead | Thermal conductivity |
Operating temperature | -20 to +50°C (-4 to 122°F) (typical) (to +55°C intermittent ) | -20 to +50°C (-4 to 122°F) (typical) (to +55°C intermittent ) | -40 to +80°C (-40 to 176°F) |
-20 to +150°C (-4 to 302°F) |
-40 to +55°C (-40 to 131°F) |
+10 to +55°C (50to 131°F) |
Humidity | 0-90% RH non-condensing |
0-90% RH non-condensing |
0-99% RH non-condensing |
0-99% RH non-condensing |
0-99% RH non-condensing |
0-90% RH non-condensing |
Repeatability Zero drift | <2% FSD (Typ.) <2% FSD / month (Typ.) |
<2% FSD (Typ.) <2% FSD / month (Typ.) |
<2% FSD (Typ.) <2% FSD / month (Typ.) |
<2% FSD (Typ.) <2% FSD / month (Typ.) |
<2% FSD (Typ.) <2% FSD / month (Typ.) |
<2% FSD (Typ.) <2% FSD / month (Typ.) |
Response time | T90 <10s Oxygen T90 <30s to 120s Toxic (sensor dependant) |
T90 <10s Oxygen T90 <30s to 120s Toxic (sensor dependant) |
90 <15s (Typ) | 90 <15s (Typ) | 90 <15s (Typ) | 90 <15s (Typ) |
Operating voltage | 8 – 30V dc | 8 – 30V dc | 2.0V dc +/- 0.1V (Typ) | 2.0V dc +/- 0.1V (Typ) | 0 – 30V dc | 0 – 30V dc |
Power requirements | 24mA max. | 24mA max. | 300mA (Typical) | 300mA (Typical) | 50mA @ 24V dc 1.2W | 50mA @ 24V dc 1.2W |
Electrical output | 2-wire 4-20mA (current sink) |
2-wire 4-20mA (current sink) |
3-wire mV bridge Typical signal 12-15mV / %lel CH4 |
3-wire mV bridge Typical signal >10mV / %lel CH4 |
3-wire 4-20mA (current sink or source) |
3-wire 4-20mA (current sink or source) |
Approvals | ATEX: II 1 G Exia IIC T4 (Tamb –40 t0 +55°C) UL/cUL Groups A,B,C,D IECEx MED Marine (96/ 98/EC) Oxygen Only | TEX: II 2 GD Exd IIC T6 (Tamb –40 to +50°C) UL: Class 1, Div. 1 Groups B,C,D IECEx MED Marine (96/98/EC) Oxygen Only | TEX: II 2 GD Exd IIC T4 (Tamb –40 to +80°C) Exd IIC T6 Tamb (-40 to + 50°C) UL: Class 1, Div. 1 Groups B,C,D IECEx | TEX: II 2 G Exd IIC T3 (Tamb –20 to +150°C) | TEX: II 2 GD Exd IIC T6 (Tamb –40 to +50°C) Exd IIC T4 Tamb (-40 to + 80°C) UL: Class 1, Div. 1 Groups B,C,D IECEx | TEX: II 2 GD Exd IIC T6 (Tamb –40 to +50°C) Exd IIC T4 Tamb (-40 to + 80°C) UL: Class 1, Div. 1 Groups B,C,D IECEx |
EMC compliance | EN 50270 | EN 50270 | EN 50270 | EN 50270 | EN 50270 | EN 50270 |
Gas type | LTEL(ppm) LEL(%vol) |
STEL(ppm) UEL(%vol) |
Ranges Available: Type 1 |
Ranges Available: Type 2 |
Ranges Available: Type 3,4,5 |
Ranges Available: Type 6 |
Acetylene (C2H2) | 2.3 (2.4) | 100 | 0-100% lel* | |||
Ammonia (NH3) | 25 15 (15) |
35 33.6 (28) |
50, 100, 250, 500, 1000 ppm | 0-25%lel* | ||
Argon (Ar) | - | - | 0-25% vv (in air)† | |||
Arsine (AsH3) | 0.05 | - | 1 ppm | |||
Bromine (Br2) | 0.1 | 0.2 | 3, 5 ppm | |||
Butane (C4H10) | 1.4 (1.8) | 9.3 (9) | 0-100% lel* | 0-25% vv (in air)† | ||
Carbon Dioxide (CO2) | 5000 (0.5%Vol) |
15000 (1.5%Vol) |
0-50%, 100% vv (in air)† | |||
Carbon Monoxide (CO) | 30 | 200 | 50, 100, 150, 200, 250, 300, 500, 1000 ppm | 50, 100, 250, 300, 500, 1000 ppm | ||
Chlorine (CL2) | - | 0.5 | 3,5,10,20,50,100 ppm | |||
Chlorine Dioxide (CLO2) | 0.1 | 0.3 | 1 ppm | |||
Diborane (B2H6) | 0.1 | - | 1 ppm | |||
Ethane (C2H6) | 2.5 (3) | 15.5 | 0-100% lel* | |||
Ethylene (C2H4) | 2.3 (2.7) | 36 | 0-100% lel* | |||
Ethylene Oxide (C2H4O) | 5 | - | 10, 50, 100 ppm | 10, 50, 100 ppm | ||
Fluorine (F2) | 1 | 1 | 1 ppm | |||
Germane (GeH4) | 0.2 | 0.6 | 2 ppm | |||
Helium (He) | - | - | 0-5%,10%,20% 50%,100% vv (in air)† |
|||
Hydrogen (H2) | 4 | 77 (80) | 200, 2000 ppm 2%, 4% vv |
200, 2000 ppm 2%, 4% vv |
0-100% lel* | 0-5%,10%,50% vv (in air) 0-20%,25%,30%,50% vv (H2 in N2) |
Hydrogen Chloride (HCL) | 1 | 5 | 5, 10, 25 ppm | |||
Hydrogen Cyanide (HCN) | - | 10 | 25, 30 ppm | |||
Hydrogen Fluoride (HF) | 1.8 | 3 | 10 ppm | |||
Hydrogen Sulphide (H2S) | 5 | 10 | 5, 10, 20, 25, 50, 100, 200, 250, 300, 1000 ppm | 5, 10, 20, 25, 50, 100, 200 ppm | ||
LPG | 2 | 10 | 0-100% lel | |||
Methane (CH4) | 4.4 (5) | 17 (15) | 0-100% lel | 0-10%,25% 100% vv (in air) 0-100% vv (CH4 in CO2)† |
||
Nitric Oxide (NO) | 5*1 | 15*1 | 25, 50, 100 ppm | |||
Nitrogen Dioxide (NO2) | 1 | 1 | 5, 10, 30, 50, 100 ppm | |||
Ozone (O3) | - | 0.2 | 1 ppm | |||
Oxygen (O2) | - | - | 25% Vol | 25% Vol | ||
Pentane (C5H12) | 1.4 (1.5) 600ppm |
7.8 (7.8) 1800ppm |
0-100% lel* | |||
Petrol | 1.3 | 6 | 0-100% lel* | |||
Phosgene (COCL2) | 0.02 | 0.06 | 1 ppm | |||
Phosphine (PH3) | 0.1 | 0.2 | 1 ppm | |||
Propane (C3H8) | 1.7 (2.2) | 10.9 (10) | 0-100% lel | 0-25% vv (in air)† | ||
Silane (SiH4) | 0.5 | 1 | 1 ppm | |||
Sulphur Dioxide (SO2) | 1 | 1 | 10, 20, 50, 100, 250 ppm | |||
Vinyl Chloride (VCM) (CH2=CHCl) |
3.6 3 |
33 - |
0-100% lel* | |||
Volatile Organics (VO)*2 | - | - | 0 - 100 ppm*2 |