- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Honeywell Analytics Midas-M TPCIP Modbus Transmitter Bulk (6) - LIT - MMT-LT02
Item #:
MMT-LT02
Brand:
Honeywell Analytics
Share this product:
MMT-LT02 Midas-M TPCIP Modbus Transmitter Bulk (6) - LIT by Honeywell Analytics
Bringing new visibility, reliability, and easeof-use to gas detection in semiconductor processing and industrial manufacturing.
An easy-to-use, cost-effective addition to the Honeywell gas detection portfolio, the Honeywell Midas®-M Gas Detector uses reliable sensor technology to detect more than 35 key toxic, ambient, and flammable gases - easily, quickly, and error-free.
The device monitors points up to 30 meters (100 feet) away while using patented technology to regulate flow rates and ensure error-free gas detection.
The standard power supply and communications capabilities include three onboard relays (Form C), 0 mA to 21 mA analog output, and Modbus®/TCP Ethernet digital outputs for easy connectivity to control and alarm systems' ports for optimal connectivity and service interaction.
With flexible features and options, the Midas-M Gas Detector works right out of the box and configures easily to meet your needs. Each plug-and-play sensor cartridge is pre-calibrated, so it's ready when you are. That means longer sensor life, quick-and-easy replacement, and no operator error due to incorrect or depleted sensors. With the Midas-M Gas Detector, customers can get extended sensor calibration periods, patented diagnostics, and lower cost of ownership.
FEATURES AND BENEFITS
- CLEAR VISIBILITY: The Midas-M Gas Detector is equipped with bright LEDs and an intuitive interface that provides instant alerts to gas readings or alarm levels.
- CALIBRATION COMPLETED: Factory-calibrated sensors reduce need for frequent gas testing.
- EASY INSTALLATION: Compact in size making it suitable for crowded, complex process environments where space is at a premium, the Midas-M Gas Detector is simple to install with its plugand-play capability.
- POE PROTOCOL: The detector includes the innovative Power over Ethernet (PoE) protocol - a single Ethernet connection for all power, control and communication requirements.
- INTEGRATED SECURITY: The Midas-M Gas Detector's interface includes passwordprotected menus to maintain system integrity.
APPLICATIONS
- Semiconductor processing
- Light industrial manufacturing
- University laboratories
- Aerospace
- Wastewater
TRANSMITTER DIMENSION | |
Size (unit with Cartridge) | 136 mm (H) x 83 mm (W) x 152 mm (D) (5.35 in x 3.27in x 5.98 in) |
Weight - Transmitter | 1.3 kg (2.87 lb) |
Weight - Cartridge | 0.17 kg ~ 0.22 kg (0.38 lb ~ 0.49 lb) dependent on sensor type |
OPTIONAL RELAY DIMENSION | |
Size | 137 mm (H) x 84 mm (W) x 41 mm (D) (5.39 in x 3.31 in x 1.61 in) |
Weight | 0.31 kg (0.68 lb) |
POWER REQUIREMENTS | |
Operating Voltage | 24 VDC Nominal, -15 to 10% (20.4 VDC to 26.4 VDC) |
Operating Voltage with Power Over Ethernet (PoE) | 48 VDC PoE (IEEE 802.3af compliant) |
POWER CONSUMPTION | |
Transmitter unit (normal condition)1 | Typ. 5 W |
Transmitter unit (full load condition)2 | ≤ 11.45 W |
Transmitter with Optional Relay | ≤ 12.9 W |
OUTPUTS | |
Visual | Alarm, Power, Fault LEDs, and LCD with all the gas readings and events. LEDs: Power (Green), Alarm 1 (Red), Alarm 2 (Red), Fault (Yellow) |
Relays in Transmitter | (3) Relays for Alarm 1, Alarm 2 and Fault rated 1.0 A @ 30 Vdc or 0.5 A @ 125 Vac Max 10 uA @ 10 mV minimum, configurable as normally open or closed, latched or unlatched |
Relays in Optional Relay | 8 relays for Alarm 1 and Alarm 2 of each channel and a relay for common fault rated 1.0 A @ 30 Vdc or 0.5 A @ 125 Vac Max 10 uA @ 10 mV minimum, configurable as normally open or closed, latched or unlatched |
Analog | 3 wire sink, 3 wire source, or 4 wire fully isolated; 0 mA to 21 mA for each channel |
Digital Communications | Modbus/TCP Ethernet/Power over Ethernet (PoE) |
CERTIFICATIONS AND SPECIFICATION | |
CE marked Meets EN 50270:2015+AC:2016 and EN 61000-6-4:2007+A1 ETL approved UL 61010-1:2012 Ed.3 IEEE 802.3af-2003 |
|
PERFORMANCE | |
Refer to individual sensor datasheets | |
TRANSPORT SYSTEM | |
Flow Rate | 600 mL/min |
Transport Time | 2 seconds to 25 seconds maximum |
Sample Line Tubing | 3.18 mm ID x 6.35 mm OD (0.125 in x 0.25 in) |
Tubing Length | Up to 30 m (100 ft) with FEP tubing |
Exhaust Line Tubing | 4.76 mm ID x 6.35 mm OD (0.188 in x 0.25 in) |
Exhaust Length | Up to 30 m (100 ft) |
Ambient Port | In line air filter required |
OPERATING TEMPERATURE | |
0°C to 40°C (32°F to 104°F) | |
WIRING REQUIREMENT | |
4-20 mA | 2 wire, 14 AWG maximum |
Digital | CAT5 Cable or equivalent: RJ45 connector |
GAS CONCENTRATION DISPLAY AND INTERFACE | |
Instrument | 4-digit alphanumeric display with separate units, concentration bar graph for each channel and other icon driven indicators 4 button interface keypad |
Remote | Internet browser access via Ethernet |
INSTALLATION DETAILS | |
Mounting | Wall mounted using pre-drilled holes on chassis. Options for DIN rail |
Material | Cover: Plastic (Polycarbonate) Chassis/Mounting bracket: Zinc plated steel Red frame: Liquid coated aluminum |
WARRANTY | |
Transmitter Unit | 1 year |
Sensor Cartridge | 2 years |
1 Normal condition: (1) No gas alarm, (2) Without tube and pressure/vacuum 2 Full load condition: (1) All 4 channels gas alarm are on, (2) Maximum tubing length and pressure/vacuum on the inlet/exhaust line |
Gas Name | Chemical Formula | Range | Sensor Part Number |
Hydrogen Chloride | HCl | 0 - 8 ppm | MMS-E2 |
Boron Trichloride | BCl3 | 0 - 8 ppm | MMS-E2 |
Dichlorosilane | SiH2Cl2 | 0 - 8 ppm | MMS-E2 |
Hydrogen Bromide | HBr | 0 - 8 ppm | MMS-E2 |
Silane | SiH4 | 0 - 20 ppm | MMS-X2 |
Disilane | Si2H6 | 0 - 20 ppm | MMS-X2 |
Hydrogen | H2 | 0 - 1000 ppm | MMS-G2 |
Chlorine | Cl2 | 0 - 2 ppm | MMS-L2 |
Ammonia | NH3 | 0 - 100 ppm | MMS-A2 |
Carbon Monoxide | CO | 0 - 100 ppm | MMS-C2 |
Phosphine | PH3 | 0 - 1200 ppb | MMS-R2 |
Ozone | O3 | 0 - 0.4 ppm | MMS-U2 |
Oxygen | O2 | 0 - 25% v/v | MMS-D2 |
Sulfur Dioxide | SO2 | 0 - 8 ppm | MMS-S2 |
Hydrogen Fluoride | HF | 0 - 12 ppm | MMS-Z2 |
Boron Trifluoride | BF3 | 0 - 8 ppm | MMS-Z2 |
Tungsten Hexafluoride | WF6 | 0 - 12 ppm | MMS-Z2 |
Datasheets & User Manuals
-
Midas-M Datasheet
Midas-M Multi Gas Relay Module Quick Reference Guide
Midas-M Multi Gas Sensor Cartridge Quick Reference Guide
Midas-M Multi Gas Transmitter Quick Reference Guide
Midas-M Chlorine (Cl2) Smart Sensor Specifications
Midas-M Carbon Monoxide (CO) Smart Sensor Specifications
Midas-M Hydrogen (H2) Smart Sensor Specifications
Midas-M Mineral Acids (HF Group) Smart Sensor Specifications
Midas-M Ammonia (NH3) Smart Sensor Specifications
Midas-M Oxygen (O2) Smart Sensor Specifications
Midas-M Ozone (O3) Smart Sensor Specifications
Midas-M Phosphine (PH3) Smart Sensor Specifications
Midas-M Sulphur Dioxide (SO2) Smart Sensor Specifications
Midas-M Silane Group (SIH4SI2H6) Smart Sensor Specifications