Specifications
The MicroDock II is for indoor use only.
Instrument dimensions: 21.2 x 26.3 x 8.2 cm (8.3 x 10.4 x 3.2 in.) base station and one docking module
Weight: 0.98 kg (2.15 lb)
Base system ingress protection: IP20
Enclosure: Impact resistant PC/ABS (polycarbonate)
Operating temperature: +10°C to +35°C (+50°F to +95°F)
Humidity: 0 to 50%
Altitude: 2000 m (6561.66 ft.)
Storage temperature: -10°C to 60°C (14°F to 140 ºF)
Power supply: 6 Vdc , 1.5 A wall adapter or four C-cell batteries (be advised that the main supply voltage fluctuations are not to exceed
10% of the nominal supply)
Pollution degree: 2
Installation category: I
Real-time clock: Provides time and date stamp
Data storage: Automatic (instrument and base station)128 MB Delkin MMC data storage system
External interface: USB interface for PC
Pump: DC motor, micro-diaphragm; 3V PCB mount
Flow rate: Maximum recommended 350 ml/min.
Calibration gas cylinder inputs:
2-gas inlets (standard)
4-gas + air inlets (maximum)
Automatic tests: Functional bump test, calibration, data transfer, audible alarm, visual alarm
Configuration recognition: Automatic (instrument and sensor)
Alarm/calibration parameters: User-settable
Calibration gas connections: Built-in (base station)
Gas connection: 1/8" SMC connect sub-miniature coupling
Solenoid: Built-in (docking modules)
LED indicators: (on each docking module)
Yellow – Test
Green – Pass
Red – Fail
Command keys:
Base station |
Menu navigation |
Docking module |
One touch bump test initiation One touch calibration initiation (not applicable to the GasAlertClip Extreme) One touch data transfer initiation
(GasAlert Extreme, GasAlertMicroClip, and GasAlertMax XT only) |
Communications method: Infrared (two-way) between docking module and detector (not applicable to the GasAlertClip Extreme – one way communication only)
USB port for connection to a:
Personal computer (PC), or
USB over IP HUB
Sensors: Audio
Optical
LCD: 4 line x 16 characters, wide viewing angle, user selectable backlighting
Warranty: 2 years
Charger Specifications
Size: 8.6 x 8.2 x 7.8 cm (3.4 x 3.2 x 3.1 in.)
Weight: 97 g (3.4 oz)
Charger system ingress protection: IP20
Operating temperature: 10°C to 35°C (50°F to 95°F)
Humidity: 0% to 50%
Altitude: 2000 m (6561.66 ft.)
Power: 6 Vdc , 2.5 A
Charging LED: Color-coded LED advises: charging, charge complete, and charger fault.
Charge time: Typically 2-6 hours
Pollution degree: 2
Installation category: I
This device complies with the FCC Part 15 and ICES-003 Canadian EMI requirements. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules and ICES003 Canadian EMI requirements.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense.
Warning
This product is designed for installation in an indoor location only. All required National Electrical Codes and Safety Standards must be followed.
For AC main installation, a circuit breaker should be included in the building installation as a disconnect device for the equipment. The disconnect device should be installed in close proximity to the
equipment and the device should be marked as a disconnecting means for the equipment.