- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Complete Tool for Water Analysis for Turbidity, Cl2, pH, Br, Fe, I and CYS- HI93102
Item #:
HI93102
Brand:
Hanna Instruments
Share this product:
HI93102 Complete Tool for Water Analysis for Turbidity, Cl2, pH, Br, Fe, I and CYS by Hanna Instruments
The most important parameters needed for water analysis, especially in drinking water, can be measured with HANNA’s HI 93102 portable meter. This instrument not only measures turbidity, but also pH, total and free chlorine, bromine, iodine, iron, and cyanuric acid (CYS). Achieve laboratory results in the field quickly and easily.
Measurements are made quickly and repeatedly through a sophisticated, yet easy-to-use microprocessor. In colorimetric mode, users can select between factory preprogrammed calibration or calibrating the meter on their own, and measure either concentration or relative absorbance of the sample. Up to 25 measured samples can be stored in memory together with time and date. Miniaturization of the electronics has made it possible to offer unsurpassed accuracy and quality in a portable unit weighing just one pound!
- USEPA Compliance. In the turbidimetric mode, the HI 93102 uses the nephelometric principle according to USEPA’s 180.1 method and the Standard Method 2130B.
- Custom Calibration Points. Advanced electronics allow operators to calibrate the meter at a selectable point in from 0.00 to 50.00 NTU.
- Logging Capability. The HI 93102 makes it possible to log and retrieve up to 25 different samples.
Order Information:
HI 93102 is supplied with measurement cuvette cap, batteries and instruction manual.
Turbidity Range | 0.00 to 9.99 NTU / 0.00 to 50.0 NTU |
Bromine Range | 0.00 to 8.00 mg/L (ppm) |
Free Cl2 Range | 0.00 to 2.50 mg/L (ppm) |
Total Cl2 Range | 0.00 to 3.50 mg/L (ppm) |
CYS Range | 0 to 80 mg/L (ppm) |
Iodine Range | 0.0 to 12.5 mg/L (ppm) |
Iron LR Range | 0.00 to 1.00 mg/L (ppm) |
pH Range | 6.5 to 8.5 pH |
Turbidity Resolution | 0.01 and 0.1 NTU |
Bromine Resolution | 0.01 mg/L (ppm) |
Free and Total Cl2 Resolution | 0.01 mg/L (ppm) |
CYS Resolution | 1 mg/L (ppm) |
Iodine Resolution | 0.1 mg/L (ppm) |
Iron LR Resolution | 0.01 mg/L (ppm) |
pH Resolution | 0.1 pH |
Turbidity Accuracy @25°C | ±0.5 NTU or ±5% of reading (whichever is greater) |
Bromine Accuracy @25°C | ±0.08 mg/L (ppm) ±3% of reading |
Free and Total Cl2 Accuracy @25°C | ±0.03 mg/L (ppm) ±3% of reading |
CYS Accuracy @25°C | ±1 mg/L (ppm) ±15% of reading |
Iodine Accuracy @25°C | ±0.1 mg/L (ppm) ±5% of reading |
pH Accuracy @25°C | ±0.1 pH |
Calibration | two points; selectable between 0.00 - 50.0 FTU (0.00 and 20.0 FTU recommended) |
Light Source | pure green LED |
Light Detector | silicon photocell |
Battery Type/Life | 1.5V AA (4) / approximately 60 hours of continuous use or 1000 measurements; automatic shut-off selectable after 10, 20, 30, 40, 50 or 60 minutes |
Environment | 0 to 50°C (32 to 122°F); RH max 95% (non condensing) |
Dimensions/Weight | 220 x 82 x 66 mm (8.7 x 3.2 x 2.6’’) / 510 g (1.1 lb.) |