1-866-4 JJSTECH(1-866-455-7832)

Hanna Total Titratable Very Low Alkalinity Titrator, 115V - HI84442-01

Item #:
HI84442-01
Brand:
Hanna Instruments
Hanna Total Titratable Very Low Alkalinity Titrator, 115V - HI84442-01
$1,143.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Hanna Total Titratable Very Low Alkalinity Titrator, 115V - HI84442-01

Hanna Total Titratable Very Low Alkalinity Titrator, 115V - HI84442-01

$1,143.00

Discontinued


HI84442-01 Total Titratable Very Low Alkalinity Titrator, 115V by Hanna Instruments

The HI 84442 is a dedicated mini titrator and pH meter designed for very low levels of alkalinity displayed as 5.0 to 20.00 mg/L as CaCO3 or 0.1 to 0.4 meq/L as CaCO3. It utilizes an electrometric titration with a pH electrode to determine the total titratable alkalinity in water. As titrant is slowly added to the sample solution the pH and temperature are carefully monitored. The software analyzes the resulting pH curve and determines the volume of titrant required to reach the endpoint of 4.5 pH. (known as bromcresol green alkalinity).

The dispensed titrant volume is used to automatically calculate the water alkalinity, which can be displayed in mg/L CaCO3 or meq/L. Titrations are conducted using the reagent HI 84442-50.

  • User-friendly interface
  • Dedicated HELP key
  • Simple to operate
  • Log on demand up to 100 samples (50 for pH; 50 for titration)
  • GLP features
  • One, two or three point calibration
  • pH temperature compensation

Order Information:

HI 84442-01 (115V) and HI 84442-02 (230V) are supplied with HI 84442-50 titrant solution (100 mL), HI 84442-55 pump calibration solution (230 mL), HI 1131B pH electrode, HI 7071 filling solution (30 mL), HI 7662-M temperature probe, HI 7061 cleaning solution, HI 7004M pH 4.01 buffer solution (230 mL), HI 70083M pH 8.30 buffer solution (230 mL), HI 7010M pH 10.01 buffer solution (230 mL), 100 mL beakers (2), tube set with dispensing tip, medium stir bars (2), 12 VDC adapter, Instructions and quick reference guide.

Total Titratable Alkalinity (Very Low/Ultra Low Range) Range mg/L (ppm) : 3.00-10.00 mg/L (ppm) as CaCO3
meq/L : 0.06-0.20 meq/L
pH Range -2.0 to 16.0 pH / -2.00 to 16.00 pH
Temperature Range -20.0 to 120.0 °C (-4.0 to 248.0 °F)
Total Titratable Alkalinity (VL/UL) Resolution 0.01 mg/L; 0.01 meq/L
pH Resolution 0.1 pH / 0.01 pH
Temperature Resolution 0.1 °C
Titratable Alkalinity (VL/UL) Accuracy (@25ºC) 5% of reading
pH Accuracy (@25ºC) ± 0.01 pH
Temperature(@25ºC) ±0.4 °C without probe error
Titration Method acid-base titration (total alkalinity)
Titration Principle endpoint titration: 4.5 pH
Pump Volume 0.5 mL/min
Stirring Speed 700 rpm
pH Temp. Compensation manual or automatic from: -20 to 120 °C (-4 to 248 °F)
Titration Logging up to 50 samples
pH Logging up to 50 samples
pH Calibration one, two or three point calibration; three available buffers (4.01; 8.30; 10.01)
pH Electrode HI 1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable
Temperature Probe HI 7662-M stainless steel temperature probe with 1 m (3.3’) cable (included)
Environment 0 to 50 °C (32 to 122 °F); max 95% RH non-condensing
Power Supply 12 VDC power adapter
Dimensions 208 × 214 × 163 mm (8.2 × 8.4 × 6.4”) (with beaker)
Weight 2200 g (77 oz.)

Datasheets & User Manuals