1-866-4 JJSTECH(1-866-455-7832)

Hanna Total Titratable Low to High Alkalinity Titrator, 230V - HI84431-02

Item #:
HI84431-02
Brand:
Hanna Instruments
Hanna Total Titratable Low to High Alkalinity Titrator, 230V - HI84431-02
$1,143.00
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Hanna Total Titratable Low to High Alkalinity Titrator, 230V - HI84431-02

Hanna Total Titratable Low to High Alkalinity Titrator, 230V - HI84431-02

$1,143.00

Discontinued


HI84431-02 Total Titratable Low to High Alkalinity Titrator, 230V by Hanna Instruments

The HI 84431 is a dedicated mini titrator and pH meter designed for low to high levels of alkalinity. It utilizes an electrometric titration with a pH electrode to determine the total titratable alkalinity in water. Titrant is slowly added to the sample solution the pH and temperature are carefully monitored. The software analyzes the resulting pH curve and determines the volume of titrant required to reach the endpoint. The user can choose either 8.3 pH (known as phenolphthalein alkalinity) or 4.5 pH (known as bromcresol green alkalinity as endpoints).

The dispensed titrant volume is used to automatically calculate the water alkalinity, which can be displayed in mg/L CaCO3 or meq/L. Titrations are conducted using the low range reagent HI 84431-50 (10 to 500 mg/L as CaCO3) or the high range reagent HI 84431-51 (400 to 4000 mg/L as CaCO3).

  • User-friendly interface
  • Dedicated HELP key
  • Simple to operate
  • Log on demand up to 100 samples (50 for pH; 50 for titration)
  • GLP features
  • One, two or three point calibration
  • pH temperature compensation

Order Information:

HI 84431-01 (115V) and HI 84431-02 (230V) are supplied with HI 84431-50 titrant solution low range (100 mL), HI 84431-51 titrant high range (100 mL) and HI 84431-55M pump calibration solution (230 mL).

Total Titratable Alkalinity (Very Low/Ultra Low Range) Range mg/L: 10.0 - 500.0 mg/L as CaCO3
meq/L : 0.3 - 10.0 meq/L
Total Titratable Alkalinity (HR) Range mg/L: 400 - 4000 mg/L as CaCO3
meq/L : 8 - 80 meq/L
pH Range -2.0 to 16.0 pH / -2.00 to 16.00 pH
Temperature Range -20.0 to 120.0 °C (-4.0 to 248.0 °F)
Total Titratable Alkalinity (VL/UL) Resolution 0.1 mg/L; 0.1 meq/L
Total Titratable Alkalinity (HR) Resolution 1 mg/L; 1 meq/L
pH Resolution 0.1 pH / 0.01 pH
Temperature Resolution 0.1 °C
Titratable Alkalinity (VL/UL) Accuracy (@25ºC) 5% of reading
Titratable Alkalinity (HR) Accuracy (@25ºC) 5% of reading
pH Accuracy (@25ºC) ± 0.01 pH
Temperature(@25ºC) ±0.4 °C without probe error
Titration Method acid-base titration (total alkalinity)
Titration Principle endpoint titration: 4.5 pH / 8.3 pH
Pump Volume 0.5 mL/min
Stirring Speed 600 rpm
pH Temperature manual or automatic from: -20 to 120 °C (-4 to 248 °F)
Titration Logging up to 50 samples
pH Logging up to 50 samples
pH Calibration one, two or three point calibration; three available buffers (4.01; 8.30; 10.01)
pH Electrode HI 1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable
Temperature Probe HI 7662-M stainless steel temperature probe with 1 m (3.3’) cable(included)
Environment 0 to 50 °C (32 to 122 °F); max 95% RH non-condensing
Power Supply 12 VDC power adapter
Dimensions 208 × 214 × 163 mm (8.2 × 8.4 × 6.4”) (with beaker)
Weight 2200 g (77 oz.)