- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Total Titratable Low to High Alkalinity Titrator, 115V - HI84431-01
Item #:
HI84431-01
Brand:
Hanna Instruments
Share this product:
HI84431-01 Total Titratable Low to High Alkalinity Titrator, 115V by Hanna Instruments
The HI 84431 is a dedicated mini titrator and pH meter designed for low to high levels of alkalinity. It utilizes an electrometric titration with a pH electrode to determine the total titratable alkalinity in water. Titrant is slowly added to the sample solution the pH and temperature are carefully monitored. The software analyzes the resulting pH curve and determines the volume of titrant required to reach the endpoint. The user can choose either 8.3 pH (known as phenolphthalein alkalinity) or 4.5 pH (known as bromcresol green alkalinity as endpoints).
The dispensed titrant volume is used to automatically calculate the water alkalinity, which can be displayed in mg/L CaCO3 or meq/L. Titrations are conducted using the low range reagent HI 84431-50 (10 to 500 mg/L as CaCO3) or the high range reagent HI 84431-51 (400 to 4000 mg/L as CaCO3).
- User-friendly interface
- Dedicated HELP key
- Simple to operate
- Log on demand up to 100 samples (50 for pH; 50 for titration)
- GLP features
- One, two or three point calibration
- pH temperature compensation
Order Information:
HI 84431-01 (115V) and HI 84431-02 (230V) are supplied with HI 84431-50 titrant solution low range (100 mL), HI 84431-51 titrant high range (100 mL) and HI 84431-55M pump calibration solution (230 mL).
Total Titratable Alkalinity (Very Low/Ultra Low Range) Range | mg/L: 10.0 - 500.0 mg/L as CaCO3 meq/L : 0.3 - 10.0 meq/L |
Total Titratable Alkalinity (HR) Range | mg/L: 400 - 4000 mg/L as CaCO3 meq/L : 8 - 80 meq/L |
pH Range | -2.0 to 16.0 pH / -2.00 to 16.00 pH |
Temperature Range | -20.0 to 120.0 °C (-4.0 to 248.0 °F) |
Total Titratable Alkalinity (VL/UL) Resolution | 0.1 mg/L; 0.1 meq/L |
Total Titratable Alkalinity (HR) Resolution | 1 mg/L; 1 meq/L |
pH Resolution | 0.1 pH / 0.01 pH |
Temperature Resolution | 0.1 °C |
Titratable Alkalinity (VL/UL) Accuracy (@25ºC) | 5% of reading |
Titratable Alkalinity (HR) Accuracy (@25ºC) | 5% of reading |
pH Accuracy (@25ºC) | ± 0.01 pH |
Temperature(@25ºC) | ±0.4 °C without probe error |
Titration Method | acid-base titration (total alkalinity) |
Titration Principle | endpoint titration: 4.5 pH / 8.3 pH |
Pump Volume | 0.5 mL/min |
Stirring Speed | 600 rpm |
pH Temperature | manual or automatic from: -20 to 120 °C (-4 to 248 °F) |
Titration Logging | up to 50 samples |
pH Logging | up to 50 samples |
pH Calibration | one, two or three point calibration; three available buffers (4.01; 8.30; 10.01) |
pH Electrode | HI 1131B glass body pH electrode with BNC connector and 1 m (3.3’) cable |
Temperature Probe | HI 7662-M stainless steel temperature probe with 1 m (3.3’) cable(included) |
Environment | 0 to 50 °C (32 to 122 °F); max 95% RH non-condensing |
Power Supply | 12 VDC power adapter |
Dimensions | 208 × 214 × 163 mm (8.2 × 8.4 × 6.4”) (with beaker) |
Weight | 2200 g (77 oz.) |