- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Hanna Checker®HC Handheld Colorimeter - Fluoride High Range - HI739
Item #:
HI739
Brand:
Hanna Instruments
Share this product:
HI739 Checker®HC Handheld Colorimeter - Fluoride High Range by Hanna Instruments
Fluoride is one of the very few chemicals that have been shown to cause significant effects in people through drinking-water. Fluoride has beneficial effects on teeth at low concentrations in drinking-water, but excessive exposure to fluoride in drinking-water, or in combination with exposure to fluoride from other sources, can give rise to a number of adverse effects.
Water fluoridation is the controlled addition of fluoride to a public water supply to reduce tooth decay. Fluoridated water operates on tooth surfaces: in the mouth it creates low levels of fluoride in saliva, which reduces the rate at which tooth enamel demineralizes and increases the rate at which it remineralizes in the early stages of cavities.
A 1994 World Health Organization expert committee suggested a level of fluoride from 0.5 to 1.0 mg/L, depending on climate. Bottled water typically has unknown fluoride levels, and some domestic water filters remove some or all fluoride.
The HI 739 Checker®HC is simple to use. In one vial add 2 ml of Reagent A and 8 ml of Reagent B; gently invert 5 times, and wait 1 minute, then zero the instrument with the vial. After zeroing, remove the vial and add 1 ml of sample, gently invert 5 times, wait 1 minute, then insert the cuvette into the HI 739 Checker®HC and press the read button for results.
- Easier to use and more accurate than chemical test kits
- Dedicated to a single parameter
- Small size, big convenience
Order Information:
HI 739 Checker®HC is supplied with sample cuvettes with caps (2), reagents for 4 tests, syringe with tip, pipette, battery and instructions.
Range | 0.0 to 20.0 ppm |
Resolution | 0.1 ppm |
Accuracy @ 25°C | ±0.5 ppm ± 5% of reading |
Light Source | LED @ 575 nm |
Light Detector | silicon photocell |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Battery Type | (1) 1.5V AAA |
Auto-off | after two minutes of non-use and ten seconds after reading |
Dimensions | 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) |
Weight | 64 g (2.25 oz.) |
Method | adaptation of SPADNS method |