- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Crowcon Gasman Single Gas Monitor, 0-1000ppm Ammonia, Rechargable Battery, English ATEX - GS-AS-A-001-G
Item #:
GS-AS-A-001-G
Brand:
Crowcon
Share this product:
GS-AS-A-001-G Gasman Single Gas Monitor, 0-1000ppm Ammonia, Rechargable Battery, English ATEX by Crowcon
For over 40 years, Crowcon Detection Instruments has produced state of the art gas detection devices for personal and industrial use. Building upon their reputation for reliable and innovative gas monitoring products, Crowcon introduces the Gasman personal gas monitor. Its lightweight and compact design is convenient for jobsites where workers need not be weighed down by excessive bulk and equipment. The unit conveniently clips to a pocket or helmet and operates continuously.
The Gasman personal gas monitor has numerous convenient features such as:
- One button technology
- Backlit LCD display
- Durable polycarbonate casing
- Quick response triple alert system
- Compact and lightweight design
Easy to Use
The Gasman’s true one button technology is an ideal and simple design. The large glove friendly button is mounted on the front of the unit for easy access and controls all of the unit’s programmable features. Also on the front, the Gasman’s easy to read backlit LCD screen indicates gas readings and the battery status. The simple screen provides a clear indication of the unit’s operation status. It will also alert the user 30 days in advance of when a calibration test is due. With a simple and intuitive design, Crowcon has produced a gas detector that reduces the complexities of workplace safety, and ensures workers in a straightforward manner that their equipment is on and operational.
Triple Alarm System
This portable single gas detection system features a triple alarm system that is sure to alert the user and anyone in the vicinity. The visible alarm utilizes a dual red and blue flashing LED light, and the unit houses an internal vibrating alert system. These two indicators allow for visual recognition in loud environments and working conditions. The alarm system also features a programmable audible alarm at 95 decibels. The unit is capable of a variety of alarm tones, and users can select which tone may be best for the individual workplace setting. The triple alarm system with multiple sensory indicators is sure to be noticed in almost any work environment.
Specifications
The Gasman single gas monitor is lightweight and compact, weighing less than 135 grams and with dimensions of 90 x 48 x 24 mm. The unit is available with a wide variety of gas sensors which feature various detection and alarm levels. The unit also features a quick response time of 20 seconds for flammable and toxic gases or 10 seconds for oxygen. Its datalogging feature has approximately 900 hours of storage and all events are time stamped. The battery life for this unit is incredible with 12 hours of runtime on a Rechargeable battery battery or up to 2 years on a non-Rechargeable battery.
Typical ranges and alarms |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Typical response times | Flammable 20s, Toxic Gas 20s, Oxygen 10s | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Audible Alarms | 95dB Multiple alarm sounds allow selection of distinctive tones for different alarm levels. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Visible Alarms | Dual colour red/blue flashing LEDs in gas hazard | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Vibrating Alarm | Internal vibrating alarm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Display | Custom LCD with backlight, with display of gas concentration. Graphic symbols for battery (with proportional indication of remaining operation time), and display mode. Start up indication when calibration is due within 30 days, calibration overdue or service required. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Display Mode | Normal display for real time gas concentration levels. Display recall for Peak readings and TWA. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Datalogging | Full timed datalogging with adjustable sample rate, set to 1 minute data
rate as default. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Battery | Rechargeable Li-ion battery for all gas types Non rechargeable Lithium battery for toxics and oxygen (excluding CO2) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Operating Time | Rechargeable: 12 hours minimum for flammable unit |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Sampling | Optional manual aspirator | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Operating temp, range | -20OC to +65OC (-4OF to +149OF) Toxic and oxygen sensors are not rated for continuous operation at high temperatures. Consult Crowcon if operating temperatures are likely to exceed 40OC (104OF) for extended periods. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Humidity | 20-90% RH | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Approval Codes |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Standards Safety |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Operation Standards | EN50270, EN50271, IEC61508, EN61779, EN45544 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
PC Interface | RS232 connection from Interface module in charger RS232/USB converter available |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Calibration | Gasman can be routinely calibrated using Portables PC software or by using Checkbox IMH | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Accessories | Gasman is supplied with an integral alligator clip. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Optional Accessories | Hard hat harness, universal harness plate, shoulder strap, chest harness, leather case, aspirator assembly (flow plate, bulb and 2m/6ft tubing) and Gas Test Kit. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Weight | Flammable: 138g (4.87oz) Oxygen: 129g (4.55oz) Toxic: 118g (4.16oz) Carbon monoxide: 139g (4.90oz) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions | 90 x 48 x 24mm (3.5 x 1.9 x 0.95 inches) H x W x D |