- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
RKI Instruments GD-K77D Smart Transmitter, Hydrogen Bromide (HBr), 0-9 PPM - GD-K77D-HBR
Item #:
GD-K77D-HBR
Brand:
RKI Instruments
Share this product:
GD-K77D-HBR Smart Transmitter, Hydrogen Bromide (HBr), 0-9 PPM by RKI Instrments
Features
- Digital display (LED) for gas concentration readout
- Calibration and other sensor Information stored in sensor memory
- Trend graph for alarm evidence
- Self-diagnostic functions by microprocessor
- Easy replacement of pump and sensor (less than one minute).
- Two alarm levels, trouble alarm, plus relay outputs
- Maintenance capability by remote PC
- Automatic flow adjustment
*Please note we can only ship RKI products to customers within the United States
Detection principle | Electrochemical cell |
Detection method | Sample drawing type |
Signal transmission | Analog transmission (4-20 mA) Two wire digital transmission |
Display | Digital LED display of gas concentration, 4 digits |
Gas alarms | Two alarm levels: 1st alarm (Yellow LED), 2nd alarm (Red LED) |
Dry outputs for remote alarms | Dry contact relay for 1st, 2nd, and trouble alarms (Normally Open or Normally Closed) |
Alarm Response Time | Approximately 10 - 15 seconds when exposed to gas concentration of 1.6 times alarm level for most gases (Same as T60) |
Self diagnosistic function | Trouble, low flow, system failure, communication error |
Operating conditions | 0 - 40°C, 30 - 85% R.H. |
Power requirements | 24 VDC |
Applicable cable | Shielded cable 3C, 1.25 sq (18 gauge) Shielded twisted one pair cable, 1.25 sq (18 gauge) |
Enclosure | Wall mounting |
Dimensions | 2.8" (W) x 6.7" (H) x 6.0" (D), approximately 4.4 lbs 70 mm (W) x 170 mm (H) x 153 mm (D), approximately 2 kg |
Ammonia (NH3) | 0 - 75.0 ppm |
Arsine (AsH3 ) | 0 - 0.20 ppm |
Boron Trichloride (BCl3) | 0 - 15.0 ppm |
Carbon Monoxide (CO) | 0 - 300 ppm |
Chlorine (Cl2) | 0 - 3.0 ppm |
Chlorine Dioxide (ClO2) | 0 - 1.00 ppm |
Chlorine Trifluoride (ClF3) | 0 - 1.00 ppm |
Diborane (B2H6) | 0 - 0.3 ppm |
Fluorine (F2) | 0 - 6.0 ppm |
Hydrogen Chloride (HCl) | 0 - 15.0 ppm |
Hydrogen Fluoride (HF) | 0 - 9.0 ppm |
Hydrogen Sulfide (H2S) | 0 -100.0 ppm |
Nitric Oxide (NO) | 0 -100.0 ppm |
Nitrogen Dioxide (NO2) | 0 - 15.0 ppm |
Ozone (O3) | 0 - 1.0 ppm |
Phosphine (PH3) | 0 - 1.0 ppm |
Silane (SiH4) | 0 - 15.0 ppm |
Sulfur Dioxide (SO2) | 0 - 30.0 ppm |