- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
RKI Instruments GD-70D Smart Transmitter, SO2 (Sulfur Dioxide), 0-6.00 ppm, Lonworks Type - GD-70DLN-SO2
Item #:
GD-70DLN-SO2
Brand:
RKI Instruments
Share this product:
GD-70DLN-SO2 GD-70D Smart Transmitter, SO2 (Sulfur Dioxide), 0-6.00 ppm, Lonworks Type by RKI Instruments
RKI Instruments has been making high quality gas detection and monitoring units for over 15 years. With an emphasis on safety and reliability, RKI Instruments excels at providing the best products in gas detection and sensor technology on the market. Every year, RKI strives to improve its product offering and scours the globe for the latest technologies and innovative designs. With the introduction of the GD-70D Series Intelligent Gas Detector, employers and workplace safety managers can feel confident that they have purchased a reliable detector that is built to last.
GD-70D Series Intelligent Gas Detector
The GD-70D Series Intelligent Gas Detector is a new smart gas detection transmitter that monitors combustibles, oxygen, and a wide range of toxic gases. The unit can be used as a standalone device, integrated with other PLC systems, or integrated with RKI's Beacon series of single and multi-channel controllers. Its common platform integrates numerous detection methods and requires very little maintenance.
Exclusive Features
The plug and play intelligent sensors make for easy setup and calibration by internally retaining calibration and sensor data. This allows workers to replace sensors while in the field without the need to reprogram the equipment. For little maintenance and optimal reliability, the internal technology automatically adjusts for long-term zero and span drift. The pump flow is also self-tuning for low maintenance functioning. In general, the smart sensors use electrochemical cell detection, semiconductor detection, pyrolysis-particle detection, galvanic cell detection, and catalytic combustion detection.
The GD-70D Series features a large LCD display that easily reads all notifications and provides a color coded graph for alarm status (first and second alarms are red, and fault alarms are yellow). The LCD screen displays the pyrolyzer connection, gas concentration, detection unit of measurement, the detected gas, the maintenance status, sensor identification, the flow rate, a graph of gas concentration, error codes, and alarm points. All operational settings are completely user adjustable from the front panel. The unit also has a self-diagnosing function which detects sensor trouble and system failure. The Intelligent Gas Detector has a convenient troubleshoot feature through its firmware. This allows users to investigate and resolve their own equipment issues while minimizing maintenance costs.
Specifications
The Intelligent Gas Detector is a convenient size for workplace and wall space efficiency with dimensions of 2.8”D x 4.7”H x 5.9”D and weighs approximately 2 pounds. It can be mounted to a wall easily with a base plate and 2 or 3 screws. Sensor replacements and pump replacements can be performed quick and easily without tools.
*Please note we can only ship RKI products to customers within the United States
Model | GD-70D |
GD-70D-NT |
GD-70D-ET |
Communication | 4-20mA DC |
DC power line communication |
PoE Method |
Detection principle | Different type depending upon sensor unit and detectable gas (see table) |
||
Sampling method | Sample drawing types (auto-adjustment of flow rate) 0.5 / min +/10% |
||
Display | Large LCD display (white backlight) Gas concentration Flowrate, communication status, Pyrolyzer status, gas detectored Error code, content of error |
||
Gas alarms | Two alarm levels: 1st alarm - Red 2nd alarm - Red Fault alarm: Yellow |
||
External output | 1st, 2nd, and trouble alarms : Relay contact output for each alarm |
||
Self diagnostic function | system failure, sensor failure, flow failure, communication error NT / ET / Analog |
||
Datalogging | Event history, alarm history, calibration history. Alarm trend (180 sec before / after 1st alarm) |
||
Operation temp. & humidity | 0 ~ 40ºC, 30 ~ 70% RH (non-condensing) |
||
Power requirements | DC 24V± 10%, approx 1.5W (Max 4W including sensor unit) Note: Approx. 2.5W (Max 5W) with SGU sensor unit |
PoE standard arrangement |
|
Operating settings | All operational settings are user adjustable through front panel |
||
Dimensions | 2.8"W x 4.7"H x 5.9"D (70W x 120H x 150Dmm) |
||
Weight | Approx. 0.9kg (2.0lbs), including sensor unit |
||
Mounting | Wall-mounting base plate by 2 or 3 screws |
||
Sampling tubing | 4 x 6mm PTFE tubing recommended. PP half union fittings provided as standard accessories |
||
Bushing | Cable type varies depending on communication method (Cable bushing optional) |
Model | ESU |
SGU |
SSU |
OSU |
NCU |
Detection principle | Electrochemical cell |
Semiconductor |
Pyrolysis-particle |
Galvanic cell |
Catalytic combustion |
Gas detected and detection range | Refer to list of detectable gases |
0-2000ppm H2, CH4, or CH2F2 (R-32) in air and others |
0-15ppm TEOS in air |
0-25% O2 in air |
0-100% LEL H2, CH4, and others |
Self diagnosis function | Sensor trouble, system failure |
||||
Date logging function | Event history, alarm history, calibration history, Alarm trend (60 sec. before/after 1st alarm) |
Model | PLU-70 |
Application | NF3 / TEOS gases detected in air |
Usage | Used by connecting to "GD-70D" (Main unit) |
Power Lamp | LED (Green color) Normal: Light-on Warming-up: Flashing at every 1 sec interval Trouble: Flashing at every 0.2 sec interval |
Self-diagnostic function | Pyrolyzer unit trouble Fan trouble System trouble |
Operating temp. & humidity | 0-40° C, 30-70% RH (non-condensing) |
Operational settings | All operational settings are user adjustable through front panel |
Power requirements | DC 24V± 10%, approx. 25W (max) |
Dimensions | 2.8"W x 4.7"H x 5.9"D (70W x 120H x 150Dmm) |
Weight | Approx. 1.2kg (2.6lbs) |
Mounting | Wall-mounting base plate by 2 or 3 screws |
Sampling | 4x6mm PTFE tubing recommended. Tube fittings provided as standard accessories |
Bushing | 1.25sq 2 core cable for power supply DC24V (Cable bushing optional) |
ESU Gas Detected | ACGIH TLV-TWA |
Detection Range |
Ammonia (NH3) | 25 ppm |
75 ppm |
Arsine AsH3 | 5 ppb |
0.2 ppm |
Bromine BR2 | 0.1 ppm |
1 ppm |
Carbon Monoxide CO | 25 ppm |
75 ppm* 150 ppm 300 ppm* |
Chlorine Cl2 | 0.5 ppm |
3 ppm 1.5 ppm* |
Chlorine Trifluoride ClF3 | (C) 0.1 ppm |
0.6 ppm |
Diborane B2H6 | 0.1 ppm |
0.3 ppm |
Disilane Si2H6 | (C) 2 ppm |
15 ppm |
Dimethylamine (CH3)2NH | 5 ppm |
15 ppm |
Diethylamine (CH3CH2)2NH | 5 ppm |
15 ppm |
Fluorine F2 | 1 ppm |
3 ppm |
Germane GeH4 | (C) 2 ppm |
0.8 ppm |
Hydrogen Bromide HBr | (C) 2 ppm |
6 ppm, 9 ppm* |
Hydrogen Chloride HCI | (C) 2 ppm |
6 ppm, 15 ppm* |
Hydrogen Fluoride HF | 0.5 ppm |
9 ppm, 3 ppm* |
Hydrogen Selenide H2Se | 0.05 ppm |
0.2 ppm |
Methylamine CH3NH2 | 5 ppm |
15 ppm |
Nitric Oxide NO | 25 ppm |
100 ppm |
Nitrogen Dioxide NO2 | 3 ppm |
15 ppm |
Nitrogen Trifluoride NF3 | 10 ppm |
30 ppm |
Ozone O3 | 0.1 ppm |
0.6 ppm |
Phosphine PH3 | 0.3 ppm |
1. ppm |
Silane SiH4 | 5 ppm |
15 ppm |
Sulfur Dioxide SO2 | — |
6 ppm |
Trimethylamine (CH3)3N | 5 ppm |
15 ppm |
Phosphine PH3 | 0.3 ppm |
0 - 1.0 ppm |
Phosphorus Oxychloride POCl3 | 0.1 ppm |
HCl 0 - 6 ppm or 0 - 15 ppm |
Phosphorus Pentachloride PCl5 | 0.1 ppm |
HCl 0 - 6 ppm or 0 - 15 ppm |
Phosphorus Pentafluoride PF5 | (C) 2 ppm |
HF 0 - 9 ppm |
Phosphorus Trichloride PCl3 | (C) 2 ppm |
HCl 0 - 6 ppm or 0 - 15 ppm |
Silane SiH4 | 5 ppm |
0 - 15.0 ppm |
Silicone Tetrachloride SiCl4 | (C) 2 ppm |
HCl 0 - 6 ppm or 0 - 15 ppm |
Silicone Tetrafluoride SiF4 | (C) 2 ppm |
HF 0 - 9 ppm |
Sulfur Tetrafluoride SF4 | (C) 2 ppm |
HF 0 - 9 ppm |
Tetraethyl Orthosilicate SiC8H20O4 | (C) 10 ppm |
TEOS 0 - 15 ppm |
Tin Tetrachloride SnCl4 | (C) 2 ppm |
HCl 0 - 6 ppm or 0 - 15 ppm |
Trichlorosilane SiHCl3 | (C) 2 ppm |
HCl 0 - 6 ppm or 0 - 15 ppm |
Tungsten Hexachloride WCl6 | (C) 2 ppm |
HCl 0 - 6 ppm or 0 - 15 ppm |
Tungsten Hexafluoride WF6 | (C) 2 ppm |
HF 0 - 9 ppm |
Hydrogen Selenide H2Se | 0.05 ppm |
0 - 0.20 ppm |
SGU Gas Detected | ACGIH TLV-TWA |
Detection Range |
Methane CH4 | 1,000 ppm |
2,000 ppm 5,000 ppm* |
Dichloroethene C2H2CL2 | 200 ppm |
600 ppm |
Isopropyl Alcohol CH3CHOHCH3 | 200 ppm |
2,000 ppm |
Propane CH3H8 | 1,000 ppm |
2,000 ppm 5,000 ppm* |
Methyl Alcohol CH3OH | 200 ppm |
1,000 ppm 2,000 ppm* |
Hydrogen H2 | — |
500 ppm* 1,000 ppm* 2,000 ppm |
Difluoromethane R-32 | 1,000 ppm |
2,000 ppm |
Fluoro Methane R-41 | 1,000 ppm |
2,000 ppm |
Carbonyl Sulfide COS | — |
2,000 ppm |
Dichloromethane CH2CL2 | 50 ppm |
2,000 ppm |
NCU Gas Detected | LEL % Vol. Levels |
Detection Range |
Methane CH4 | 5% Vol. |
100% LEL 2.0 Vol. |
Isobutane i-C4H10 | 1.8% Vol. |
100% LEL |
Hydrogen H2 | 4% Vol. |
2.0 Vol. |
SSU Gas Detected | ACGIH TLV-TWA |
Detection Range |
Trimethyl Silane TMS | — |
15 ppm |
Trimethoxysilane TRIMOS | — |
15 ppm |
Tetraethyl Orthosilicate TEOS | 10 ppm |
15 ppm |
OSU Gas Detected | ACGIH TLV-TWA |
Detection Range |
Oxygen O2 | — |
25% Vol. |