Instrument dimensions: 14.5 x 7.4 x 3.8 cm (5.7 x 2.9 x 1.5 in.)
Weight: 370 g (13.1 oz.)
Operating and storage conditions Temperature:VOC: -10°C to +40°C (-14°F to +104°F) Other gases: -20°C to +50°C (-4°F to +122°F)
Humidity: O2: 0% to 99% relative humidity (non-condensing) VOC: 0% to 95% relative humidity (non-condensing) Combustibles: 5% to 95% relative humidity (non-condensing)
Cl2: 10% to 95% relative humidity (non-condensing)
HCN, ClO2: 15% to 95% relative humidity (non-condensing)Other gases: 15% to 90% relative humidity
(non-condensing)
ressure: 95 to 110 kPa
Alarm setpoints: May vary by region and are user-settable.
Detection range: O2: 0 – 30.0% vol. (0.1% vol. increments)
CO: 0 – 999 ppm (1 ppm increments)
CO (TwinTox sensor): 0 – 500 ppm (1 ppm increments)
H2S: 0 – 500 ppm (1 ppm increments)
H2S (TwinTox sensor): 0 – 500 ppm (1 ppm increments)
Combustibles: 0 – 100% LEL (1% LEL increments) or
0 – 5.0% v/v methane
PH3: 0 – 5.0 ppm (0.1 ppm increments)
SO2: 0 – 150 ppm (1 ppm increments)
Cl2: 0 – 50.0 ppm (0.1 ppm increments)
NH3: 0 – 100 ppm (1 ppm increments)
NO2: 0 – 99.9 ppm (0.1 ppm increments)
HCN: 0 – 30.0 ppm (0.1 ppm increments)
ClO2: 0 – 1.00 ppm (0.01 ppm increments)
O3: 0 – 1.00 ppm (0.01 ppm increments)
VOC: 0 – 1000 ppm (1.0 ppm increments)
Sensor type:H2S/CO: Twin plug-in electrochemical cell
Combustibles: Plug-in catalytic bead
VOC: Photoionization detector (PID)
Other gases: Single plug-in electrochemical cell
O2 measuring principle:Capillary controlled concentration sensor
Alarm conditions:TWA alarm, STEL alarm, low alarm, high alarm, multi-gas alarm, over range alarm, sensor alarm, pump alarm, MMC fail alarm, low battery alarm, confidence beep, automatic shutdown alarm
Audible alarm: 95 dB at 1 ft. (0.3 m) variable pulsed dual beepers
Visual alarm: Dual red light-emitting diodes (LED)
Display: Alphanumeric liquid crystal display (LCD)
Backlight: Automatically activates whenever there is insufficient light to view the LCD (if enabled) and during alarm conditions.
Self-test: Initiated upon activation
Calibration: Automatic zero and automatic span
Oxygen sensor: Automatic span upon activation (selectable)
User field options: Confidence beep, latching low and high alarms, pass code protection, enable/disable safe display mode, enable/disable fast pump, combustible sensor measurement, sensor disable, TWA and STEL, language selection, enable/disable automatic oxygen calibration, set span concentration values, set STEL calculation period, set TWA method, gas measurement resolution, enable/disable automatic
backlight, adjust clock calendar, and set logging rate (datalogger models only).
Datalogger units: Use only Infineon 32 MB MMCs
Datalogger units: Use only Infineon 32 MB MMCs
Battery operating time:
Toxic, O2, and LEL sensors: 20 hours (three alkaline cells or one rechargeable battery pack)
Toxic, O2, LEL, and PID sensors: 10 hours (three alkalinem cells or one rechargeable battery pack)
Approved batteries:Approved batteries for product (standards IEC 60279-11, EN50020, UL913, C22.2 No. 157)
Alkaline: Temperature Code
Duracell MN1500 -20°C ≤Ta ≤ +50°C ; T3C (139.8o C)
-20°C ≤Ta ≤ +40°C T4 (129.8oC)
Energizer E91 -20°C ≤Ta ≤ +50°C T3B (163oC)
-20°C ≤Ta ≤ +40°C T3C (153oC)
NiMH rechargeable:
M5-BAT01 -20°C ≤Ta ≤ +50°C T4
Battery charger: GasAlertMicro 5 battery charger
First-time charge: 4 hours per battery pack
Normal charge: 3-4 hours per battery pack
Warranty: : 2 years including sensors
(1 year for NH3 sensor and PID lamp)
Approvals Approved by CSA to both U.S. and Canadian Standards
Approved: Class l, Division 1, Group A, B, C, and D; Class l, Zone 0, Group llC
Standards: CAN/CSA C22.2 No. 157 and C22.2 152 ANSI/UL – 913 and ANSI/ISA – S12.13 Part 1
ATEX: CE 0539 g ll 1 G EEx ia llC KEMA 05ATEX 1096X
IECEx: Ex ia llC
ABS Type Approved: VA-348169-X
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and ICES-003 Canadian EMI requirements. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
General Specifications for Datalogger Units
Media type: MultiMediaCard (MMC)
Size: 32 MB (Infineon MMC only)
Storage:500,000 lines of data available; 4.4 months at 5 second intervals (based on a normal work week)
Memory type: Wrap-around memory ensures most recent data is always saved
Sample rate: One reading every 5 seconds (standard)
Data recorded: All sensor readings, all alarm conditions, calibrations, event flags, battery status, pump status, sensor status, confidence beep activation, and detector status along with the time and date for each reading and unit serial number
MMC/SD test: Automatically on activation
GasAlertMicro 5 and GasAlertMicro 5 PID with User Downloadable Datalogger
Operation:Requires no user intervention (automatic)
Indicators: Icon advises datalogger is operating normally, MMC/SD missing/malfunction advise
Compatible with:Desktop PC computer or laptop
Operating system:Windows 95 or higher; Macintosh OS 8.6 or higher
Download via:MMC/SD card reader.
Software required:Spreadsheet or database compatible with comma-separated-value (CSV) text files (Excel, Access, Quattro, etc.)
Card alarm:Card fail or missing
Support:
Fleet Manager:Fleet Manager is an Access software addin that enhances the abilities of Microsoft® Access when handling GasAlertMicro 5 user downloadable datalogger data files.