1-866-4 JJSTECH(1-866-455-7832)

Extech SDL200 4-Channel Datalogging Thermometer with NIST

Item #:
EXT-SDL200-NIST
Brand:
Extech
Extech SDL200 4-Channel Datalogging Thermometer with NIST
$509.99
Qty

Discontinued

Send This Page to a Friend

Ask an Expert

Our tech experts are ready to help!

1-866-4 JJSTECH (1-866-455-7832)

Email Us
Share this product:
Extech SDL200 4-Channel Datalogging Thermometer with NIST

Extech SDL200 4-Channel Datalogging Thermometer with NIST

$509.99

Discontinued


SDL200 4-Channel Datalogging Thermometer with NIST by Extech

Features

  • 4-Channel datalogging with 6 Thermocouple types (J, K, E, T, R,S) and 2-Channel datalogging with RTD (Pt100?) probes
  • Displays [T1, T2, T3, T4] or differential [T1-T2] reading
  • Offset adjustment used for zero function to make relative measurements
  • Stores 99 readings manually and 20M readings via 2G SD card
  • Records readings with real date and time stamp
  • User programmable sampling rate: 1 to 3600 seconds
  • Min/Max and Data Hold functions
  • Auto power off with disable function
  • Built-in PC interface
  • Complete with 6 AA batteries, four general purpose Type K bead wire temperature probes, SD card, and hard carrying case
General Specifications
Display Backlit LCD; LCD size: 2 x 1.5"(52 x 38mm)
Status indicators Over-range (----) and low battery (battery symbol)
Measurement Channels T1, T2, T3, T4, and T1-T2
Sensor types Thermocouple types: K, J, T, E, R, and S
RTD type: platinum 100 ohm (Complies with 0.00385 alpha coefficient meeting DIN IEC 751)
Measurement Units °C / °F
Offset Adjustment Available for one (1) thermocouple and two (2) RTD inputs
Input Linearity Sensor curves are stored in meter's CPU
Datalogger Sampling Rate AUTO LOGGING: 1, 2, 5, 10, 30, 60, 120, 300, 600, 1800, 3600 seconds. Note that a one (1) second sampling rate can cause some data loss on slower computers MANUAL LOGGING: Set the sampling rate to '0'
Memory Card SD memory card; 1G to 16GB size
Temperature Compensation Auto temperature compensation for all thermocouple types
Display update rate Approx. 1 second.
Data Output RS-232 / USB PC computer interface
Operating Temperature 32 to 122°F (0 to 50°C)
Operating Humidity 85% R.H. max.
Auto Power OFF After 10 minutes of inactivity (can be disabled)
Power Supply Six (6) 1.5 VDC batteries (optional 9V AC adaptor)
Power Consumption Normal operation (backlight & datalogger OFF): approx. 9.7mA dc
With backlight OFF and datalogger ON: approx. 30mA dc
With backlight ON and datalogger OFF: approx. 17mA dc
Weight 0.62 lbs (280g) meter only
Dimensions Main instrument: 7.1 x 2.9 x 1.9"(182 x 73 x 47.5mm)

Electrical Specifications
Sensor Type
Resolution
Range
Accuracy
Type T
0.1°C
50.1 to -100.0°C
±(0.4 % + 1°C)
-50.0 to 999.9°C
±(0.4 % + 0.5°C)
1°C
1000 to 1300°C
±(0.4 % + 1°C)
0.1°F
-58.1 to -148.0°F
±(0.4 % + 1.8°F)
-58.0 to 999.9°F
±(0.4 % + 1°F)
1°F
1000 to 2372°F
±(0.4 % + 2°F)
Type J
0.1°C
-50.1 to -100.0°C
±(0.4 % + 1°C)
-50.0 to 999.9°C
±(0.4 % + 0.5°C)
1°C
1000 to 1150°C
±(0.4 % + 1°C)
0.1°F
-58.1 to -148.0°F
±(0.4 % + 1.8°F)
-58.0 to 999.9°F
±(0.4 % + 1°F)
1°F
1000 to 2102°F
±(0.4 % + 2°F)
Type T
0.1°C
-50.1 to -100.0°C
±(0.4 % + 1°C)
-50.0 to 400.0°C
±(0.4 % + 0.5°C)
0.1°F
-58.1 to -148.0°F
±(0.4 % + 1.8°F)
-58.0 to 752.0°F
±(0.4 % + 1°F)
Type E
0.1°C
-50.1 to -100.0°C
±(0.4 % + 1°C)
-50.0 to 900.0°C
±(0.4 % + 0.5°C)
0.1°F
-58.1 to -148.0°F
±(0.4 % + 1.8°F)
-58.0 to 999.9°F
±(0.4 % + 1°F)
1°F
1000 to 1652°F
±(0.4 % + 2°F)
Type R
1°C
0 to 600°C
±(0.5 % + 3°C)
601 to 1700°C
1°F
32 to 1112°F
±(0.5 % + 5°F)
1113 to 3092°F
Type S
1°C
0 to 600°C
±(0.5 % + 3°C)
601 to 1500°C
1°F
32 to 1112°F
±(0.5 % + 5°F)
1113 to 2732°F

Datasheets & User Manuals

Questions & Answers