Features

  • Measures DC Current, AC/DC Voltage, and Resistance
  • Diode and Continuity test
  • Max hold function
  • 0.7" (18mm) jaw opening; 300MCM cable size
  • Built-in AC non-contact Voltage (NCV) detector (120/240VAC, 50/60Hz)
  • LCD backlit display
  • Built-in white LED flashlight
  • Auto Power Off
  • Complete with two AAA batteries and soft case
General Specifications
Display 2000 count Digit LCD with white LED backlight
Polarity Minus sign ( - ) indicates negative polarity
Jaw opening 0.7" (18mm)
Current sensor Hall effect sensor type
AC Current Bandwidth 50/60Hz
AC Voltage Bandwidth 50/400Hz
Overload indication "OL" displayed on the LCD
Display rate 2 readings/second, nominal
Battery Two 1.5V AAA batteries
Low Battery indication "BATT" displayed on the LCD
Auto Power off approx. 15 minutes
Operating conditions 32 to 86ºF (0 to 30ºC) 90%RH; 86 to 104ºF (30 to 40ºC) 75%RH; 104 to 122ºF (40 to 50ºC) 45%RH
Storage conditions - 14 to 140ºF (-30 to 60ºC); < 90% Relative Humidity
Altitude Operate at less than 3000 meters
Weight 6.2 oz. (176g) including battery
Dimensions 6.5 x 2.6 x 1.3” (164 x 65 x 32mm) (HWD)
Standards For indoor use and in accordance with the requirements for double insulation to IEC1010-1 (1995): EN61010-1 (1995) Overvoltage Category III 300V and Category II 600V, Pollution Degree 2.

Range Specifications
Function Range Resolution Accuracy (of reading)
AC Current 200.0A 0.1A ± (2.5% rdg + 10 digits)
DC Voltage 200.0mV 0.1mV ±(0.5% rdg + 5 digits)
2.000V 1mV ±(1.2% rdg + 3 digits)
20.00V 10mV
200.0V 0.1V
600V 1V ±(1.5% rdg + 3 digits)
AC Voltage 2.000V 1mV ±(1.5% rdg + 3 digits)
20.00V 10mV
200.0V 0.1V
600V 1V ±(2.0% rdg + 4 digits)
Resistance 200.0Ω 0.1Ω ±(1.0% rdg + 4 digits)
2.000kΩ ±(1.5% rdg + 2 digits)
20.00kΩ 10Ω
200.0kΩ 100Ω
2.000MΩ 1kΩ ±(2.0% rdg + 3 digits)
20.00MΩ 10kΩ ±(3.0% rdg + 5 digits)
Non-Contact AC Voltage 100VAC to 600VAC 50/60Hz
Diode Test Test current: 0.3mA typical;
Open circuit voltage: 1.5VDC typical
Continuity Threshold <120Ω; Test current <1m