- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Extech 42510A Wide Range Mini IR Thermometer
Item #:
EXT-42510A
Brand:
Extech
Share this product:
42510A Wide Range Mini IR Thermometer by Extech
Features
- Compact thermometer measures temperature from -58 to 1200°F (-50 to 650°C) with 0.1° resolution up to 999.9°
- Adjustable High/Low setpoints with audible alarm alerts user when temperature exceeds the programmed setpoints
- Adjustable emissivity for better accuracy on different surfaces
- Built-in laser pointer identifies target area
- Backlighting illuminates display for taking measurements at night or in areas with low background light levels
- 12:1 distance to target ratio
- Data Hold and Min/Max
- Overrange indicator
- Auto power off
- Complete with 9V battery and pouch case
Display | Backlit LCD display with function indicators |
Response time | 300ms |
Over range indication | "---------" |
Operating Temperature | 0ºC to 50ºC (32ºF to 122ºF) |
Operating Humidity | 10% to 90%RH operating, <80%RH storage. |
Storage Temperature | -10 to 60ºC (14 to 140ºF) |
Power Supply | 9V battery |
Automatic Power Off | 7 seconds, with LOCK to disable |
Weight | 6.4 oz. / 180g |
Dimensions | 82 x 42 x 160mm (3.2 x 1.6 x 6.3") |
Range / Resolution | 0.1° resolution from -50.0 to 650.0°C (-58.0 to 999.9°F); 1° resolution from 1000°F to 1200°F |
Accuracy | -50°C to -35°C (-58°F to -31°F); ±4°C/9°F -35°C to -2°C (-31°F to 28°F); ±3°C/5°F -2°C to 94°C (28°F to 200°F); ±2.5°C/3°F 94°C to 204°C (200°F to 400°F); ±(1.0%rdg + 1°C/2°F) 204°C to 426°C (400°F to 800°F); ±(1.5%rdg + 1°C/2°F) 426°C to 650°C (800°F to 1200°F); ±(2.0%rdg +1°C/2°F) Note: Accuracy is specified for the following ambient temperature range: 18 to 28°C (64 to 82°F) |
Emissivity | 0.10 to 1.00 adjustable |
Field of View | D/S = Approx. 12:1 ratio (D = distance; S = spot or target) |
Laser pointer | Class 2 laser < 1mW power; Wavelength: 630 to 670nm |
IR Spectral response | 8 to 14μm |
Repeatability | ± 0.5% of reading or ± 1°C/1.8°F; whichever is greater |