- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Casella Noise Dosimeter 5 Pack Kit with Standard Items
Item #:
CEL-320X-K5
Brand:
Casella
Share this product:
CEL-320X-K5 Noise Dosimeter 5 Pack Kit with Standard Items by Casella
The CEL-320 Noise dosimeter is a low cost simple to use instrument specifically designed for monitoring the noise exposure of an individual at work.
Many different worldwide measurement protocols are currently in operation and the CEL-320 dosimeter is able to satisfy them all using built-in setups.
Simply select the setup required for the measurement, press the run button and the instrument takes care of all the rest for you.
Key Benefits
- Light weight and rugged
- Pre programmed with the most important setups
- Make OSHA, MSHA, DoD, ACGIH style measurements by simple selection from menu
- Configure the dosimeter for specific measurements if needed
- Calculate the overall results for up to 50 separate runs
- Store % noise dose, 8 hour projected dose, max, min, peak and average levels
- Two thresholds and single criterion level
Applications
Whenever simple straight-forward noise measurements are required on individuals at work the CEL-320 is ready to go. By default, the instrument starts with the most popular OSHA measurement setup with all the correct parameters such as the A frequency and Slow time weighting already selected. The 5 dB exchange rate and 90 dB criterion level are programmed into the unit so it is only required to switch the meter on, perform an acoustic field calibration and start the run. The instrument takes care of everything else.The instrument selects the high measurement range from 70 to 140 dB to include all the likely harmful noise levels typically encountered in the workplace. The signal from the microphone is sampled and all subsequent noise parameters are calculated from these samples taken at 100 times a second. This ensures that no data, however short, is missed fromthe overall results. The data can be recalled and read from the display at any time. The results stored in memory can be directly printed or downloaded to a computer.
CEL-320 dosimeters are available in single kits that include an acoustic calibrator for on-site verification of the meter, a small foam windscreen to protect the microphone when used outdoors, setup and download software an cable all housed in a stylish kit case. Multiple kits are also available in popular 5 or 10 packs that expand the usefulness of the instrument for larger organizations wanting to get the job done in the least possible time. A single copy of the CEL dB10 software serves all meters in the kits.
Operation and use
Every CEL-320 noise dosimeter comes with the CEL-6702 (dB10) Windows software package that allows the user to customize the instrument to take account of special circumstances or for special measurement require-ments. It is possible to turn off the functions that are not needed from a run to simplify operation and avoid later confusion.The CEL software package (dB10) currently supplied with each unit allows for the overall results from runs to be downloaded one at a time or in batches to the hard disk. Runs may be archived after the details of the wearer have been added and saved along with any specific notes about the conditions during the run.
Run data may be recalled to the customized LCD screen using the intuitive keypad or the instrument can be connected to a standard office printer and output as a single pre-formatted page. This printout shows all the relevant information about the run including the calibration details before and after the measurement has taken place.
International standards | Parameters measured | ||
Acoustic accuracy | ANSI S1.25-1992 Type 2 IEC 61252:1993 |
Displayed parameters | Lp, LAeq, LAE, LeqI, Lav, Lmx, Lmn, 5 x LN%, actual noise dose%, 8 hr projected noise dose%, TWA (at both threshold levels), LEPd, duration of run, current date, time, run #, pause, run in progress, battery voltage, security level |
Electro-magnetic | EN 50081-1:1992, EN 50081-2:1993, EN 50082-1:1992, EN 50082-2:1995 |
||
Measurement ranges (for rms. levels) |
High range 70 – 140 dB Med range 50 – 120 dB Low range 30 – 100 dB |
||
Peak ranges | Top 40 db of each range | ||
Measurements stored | |||
Separate runs (events) | Maximum 50 | Physical characteristics | |
Factory setups | 7 - OSHA, MSHA, DoD, ACGIH, ISO85, ISO90, METER | Battery pack | 1 9V radio battery Duracell MN 1604 |
User setups | 13 – programmed from pc | Battery life | 50 hours (approx.) |
Threshold levels (dB) | 2 (from 70 to 90 dB) | Size | 4.8 x 2.6 x 1.2 in, 120 x 65 x 30 mm |
Criterion level (dB) | 1 (from 80 to 90 dB) | Weight | 11 oz, 300 gm |
Frequency weightings | A, C for rms. C, Lin for peak |
Microphone assembly | Rugged Electret ¼ in microphone on 32 in cable with locking plug, field replaceable item |
Time weightings | Slow, Fast, Impulse, peak | ||
Exchange rates | 3, 4, 5, 6 dB doubling | Optional stalk mic. | Electret ¼ in stalk, 3.1in |