18.Troubleshooting
If a problem occurs, refer to the solutions provided here. If the problem persists, contact Technical Support.
Problem |
Possible Cause |
Solution |
The detector does not activate. |
No battery. |
Depleted battery. |
Damaged or defective detector. |
Reversed battery. |
|
Install a battery |
Replace the battery |
Contact Technical Support. |
Reinstall the battery correctly. |
|
The detector enters alarm mode immediately when it is activated. |
Sensor needs to stabilize. |
Low battery alarm |
Sensor alarm |
|
Used sensor: Wait 60 seconds. New sensor: Wait 5 minutes |
Replace the battery |
Replace the sensor. |
|
The start-up self-test fails during one of the checks. |
General fault |
Alarm setpoints are incorrect |
|
Contact Technical Support |
Reset the alarm setpoints. |
|
The detector does not display a normal ambient gas reading after the activation self-test. |
Target gas is present |
Detector requires calibration |
Sensor not stabilized |
|
Detector is operating properly. Use caution in suspect areas |
Calibrate the detector |
Used sensor: Wait 60 seconds. New sensor: wait 5 minutes |
|
The detector does not respond to the pushbutton. |
Battery is depleted. |
Detector is performing operations that do not require user input. |
|
Replace the battery. |
Pushbutton operation restores automatically when the operation ends. |
|
The detector does not accurately measure the gas. |
Detector requires calibration |
Detector is colder or hotter than the ambient gas. |
Sensor filter is blocked |
|
Calibrate the sensor. |
Allow the detector to acquire ambient temperature before use |
Clean the sensor filter. |
|
The detector does not enter alarm mode. |
Incorrect setting of alarm setpoint(s). |
Alarm setpoint(s) set to zero. |
Detector is in calibration mode. |
|
Reset the alarm setpoints. |
Reset the alarm setpoints |
Complete the calibration. |
|