WEIGHT |
7.9 oz. (instrument with battery and clip) |
DIMENSIONS (L x W x H) |
4.4 x 3.00 x 1.37 inches – without fastening clip |
ALARMS |
Four gas alarm LEDs, a charge status LED, an audible alarm, and a vibrating alarm |
VOLUME OF AUDIBLE ALARM |
95 dB typical |
DISPLAY |
LCD display |
BATTERY TYPE |
Rechargeable Li polymer battery. Li polymer battery must not be charged in Ex area |
INSTRUMENT RUN TIME |
24 hours at 77°F (25°C) |
CHARGING TIME |
? 4 hours
The maximum safe area charging voltage Um = 6.7 Volts D.C |
TEMP RANGE |
14 to 104°F (-10 to 40°C) Normal operating range -4 to 122°F (-20 to 50°C) Extended operating range 50 to 95°F (10 to 35°C) While charging battery -40 to +140°F (-40 to 60°C) Intrinsic safety ambient temperature range (ATEX, IEC) -40 to +129°F (-40 to 54°C) Intrinsic safety ambient temperature range (CSA, ETL) |
HUMIDITY RANGE |
15 - 90% relative humidity, non-condensing; 5 - 95% RH intermittent |
ATMOSPHERIC PRESSURE RANGE |
800 to 1200 mbar |
INGRESS PROTECTION |
IP 67 |
MEASURING METHODS |
Combustible gas: Catalytic sensor O2 and Toxic gas: Electrochemical sensor |
MEASURING RANGE |
Combustible O2 CO H2S 0-100% LEL 0-30% Vol. 0-1999 ppm 0-200 ppm 0-5.00% CH4 |