5.3 Certifications
See instrument label for the approvals that apply to your specific unit.
USA and Canada (Non-mining) See instrument label for approvals that apply to your specific unit |
USA (Mining) MSHA 30 CFR Part 22, Methane Detector. Approved for 30 CFR Part 75 Determination testing for methane and oxygen deficiency |
Europe Union The product ALTAIR 4X complies with the following directives, standards or standardized documents: |
Directive 94/9/EC (ATEX): II 1G Ex ia IIC T4, Ga IP67 (Zone 0 with no combustible sensor installed) II 2G Ex d ia mb IIC T4 Gb, IP67 (Zone 1 with combustible sensor installed) I M1 Ex ia I Ma (Zone 0) Ta = -40 °C to +60 °C EN60079-29-1 ATEX Flammable Gas Performance Certification for Groups I and II EN50104 ATEX Oxygen Performance Certification |
CE 0080 Directive 2004/108/EEC (EMC): EN50270:2007 Type 2, EN61000-6-3:2007 |
Australia/New Zealand Test Safe Australia Ex ia sa I IP67 (Zone 0) Ex ia sa IIC T4 IP67 (Zone 0) Ta = -40 °C to +60 °C |
IECEx TestSafe Australia Ex ia I IP67 (Zone 0) Ex ia mb d IIC T4 IP67 (Zone 1) - When Combustible XCell Sensor is installed Ex ia IIC T4 IP67 (Zone 0) - When Combustible XCell Sensor is not installed Ta = -40 °C to +60 °C |