Alarms

Alarms

Refer to the following table for information about alarms and corresponding screens.

AlarmScreen

Low Alarm

  • Slow siren
  • Slow alternating flash
  • Alarm and target gas bar flash
  • Vibrator alarm activates
Gas alarm

High Alarm

  • Fast siren
  • Fast alternating flash
  • Alarm and target gas bar flash
  • Vibrator alarm activates
Gas alarm

Multi-Gas Alarm

  • Alternating low and high alarm siren and flash
  • Alarm and target gas bars flash
  • Vibrator alarm activates
Gas alarm

TWA Alarm

  • Fast siren
  • Fast alternating flash
  • Alarm and target gas bar flash
  • Vibrator alarm activates
Gas alarm

STEL Alarm

  • Fast siren
  • Fast alternating flash
  • Alarm and target gas bar flash
  • Vibrator alarm activates
Gas alarm

Over Limit (OL) Alarm

  • Fast siren
  • Fast alternating flash
  • Alarm and target gas bar flash
  • Vibrator alarm activates
Gas alarm

Note If the Low Alarm Acknowledge option is enabled in Fleet Manager II, the low alarm can be acknowledged and the audible alarm deactivated by pressing Gas alarm. If the alarm escalates to a high, STEL, TWA, or multi-gas alarm, the audible alarm reactivates

AlarmScreen

Sensor Alarm

  • ERR displays
Gas alarm

Low Battery Alarm

  • Sequence of 10 rapid sirens and alternating flashes with 7 seconds of silence in between (continues for 10 minutes)
  • Alarm and Alarm flashes
  • LOW BATTERY displays and the vibrator alarm activates
  • After 10 minutes, a sequence of 10 rapid sirens and alternating flashes with 1 second of silence in between (reactivates seven times)
  • TURNING OFF displays before the detector deactivates
Gas alarm

Automatic Deactivation Alarm

  • Sequence of 10 rapid sirens and alternating flashes with 1 second of silence in between (reactivates seven times)
  • Alarm flashes and the vibrator alarm activates
  • TURNING OFF displays before the detector deactivates
Gas alarm

Pump Alarm

  • Two beeps and two flashes
  • Alarm and Alarm flashes
  • HIGH displays
  • The vibrator alarm activates
Gas alarm

Note If enabled, during an alarm condition the Latched Alarms option causes the low and high gas alarms (audible, visual, and vibrator) to persist until the alarm is acknowledged (by pressing Gas alarm) and the gas concentration is below the alarm setpoint. The LCD continues to display the high peak concentration until the alarm condition no longer exists. Enable/disable Latching Alarms in Fleet Manager II. Local regulations may require the Latching Alarms option be enabled.