- All Products
- Shop by Brands
- BW Technologies
- BW Technologies
- BW Technologies Monitors
- Models
- BW Clip
- BW Clip4
- GasAlertClip Extreme
- GasAlert Extreme
- GasAlertMicroClip XT
- GasAlertMicroClip XL
- GasAlertMicroClip X3
- GasAlertQuattro
- GasAlertMax XT II
- GasAlertMicro 5 Series
- SamplerPak
- IntelliDox Docking System
- MicroDock II
- BW Ultra
- BW Solo
- Gas Monitors
- Gas Monitor Manufacturers
- BW Technologies
- Bacharach
- Biosystems
- Crowcon
- Gas Clip Technologies
- GfG Instruments
- GMI/Detcon
- Honeywell Analytics
- Industrial Scientific
- MSA
- RAE Instruments
- RKI Instruments
- Calibration Gas
- Combustion Analyzers
- Water Quality
- Reliability Instruments
- Refractometers
- HVAC
- Weather
- Temperature
- Laboratory
- Sound
- IAQ
- Electrical
- All Categories
Honeywell Analytics Satellite XT Gas Detector, Digital Sensor Heads with Extractive Module, FTT/C UL with UL fitting not certified to UL - 9602-0451-EXT
Item #:
9602-0451-EXT
Brand:
Honeywell Analytics
Share this product:
9602-0451-EXT Satellite XT Gas Detector, Digital Sensor Heads with Extractive Module, FTT/C UL with UL fitting not certified to UL by Honeywell Analytics
The Satellite XT is the simple solution for all "Point-of-Use" gas detection needs. Based upon the market's smallest and most reliable electrochemical cell technology, the Satellite XT offers flexibility, simplicity and ease of application. The Satellite XT can be purchased in either an analog or digital configuration, allowing it to interface with new or existing facility control technologies.
The digital Satellite XT is built on LonWorks® technology. Life safety systems built on a LonWorks® network platform allow users to leverage the cost efficiencies of distributed controls, while maintaining the integrity and reliability necessary for code compliant safety applications.
The Satellite XT is an intelligent gas detection transmitter which utilizes a unique electrochemical sensor to detect toxic, corrosive, and combustible gas.
The Satellite XT is a "Point-of-Use" monitor normally located at or near a potential source of gas release. Field accessories allow sampling options for various environments including in-situ duct detection and extractive designs for harsh or remote areas. Typical installations for gas detection sampling include gas cabinet exhaust ducting, valve manifold boxes, equipment enclosures and ambient breathing zones.
Each digital Satellite XT transmitter bears a unique address for use on a LonWorks® network. This feature allows it to participate in a community of other intelligent LonWorks® devices, which when considered together, comprise a life safety system network. Gas concentration and alarm information are both displayed locally at the Satellite XT, as well as distributed onto the LonWorks® network for use by other field devices. The Satellite XT provides complete programmability of all monitoring variables including gas type, alarm levels, and maintenance status.
Applications: Provides gas detection for:
- Gas cabinets
- Valve manifold box
- Equipment enclosure
- Ambient breathing zone
- Gas storage rooms
- OEM equipment
Advantages:
- Fast, reliable, specific gas detection
- Continuous real-time monitoring
- Interchangeable intelligent sensor cell
- No dynamic gas calibration required
- Generic sensor head electronics
- Low cost of ownership
- No moving parts to wear down or replace
Satellite XT FTT |
Satellite XT FTT/R |
Satellite XT FTT/C |
Satellite XT R |
||
Power requirements | Voltage | 12 to 24 VDC |
12 to 24 VDC |
12 to 24 VDC |
12 to 24 VDC |
Consumption | max. 0.6W |
max. 1.4W |
max. 0.9W |
max. 1.4W |
|
Network | Data transmission | 78Kb per second |
78Kb per second |
78Kb per second |
|
Wiring topologies | Free, e.g. Bus, Star, Loop, or Mixed |
Free, e.g. Bus, Star, Loop, or Mixed |
Free, e.g. Bus, Star, Loop, or Mixed |
||
Wiring | Network | 4-wire shielded cable 2 x 2 x 1.0mm2/17 AWG (approx. 2m delivered with instrument) |
4-wire shielded cable 2 x 2 x 1.0mm2/17 AWG (approx. 2m delivered with instrument) |
4-wire shielded cable 2 x 2 x 1.0mm2/17 AWG (approx. 2m delivered with instrument) |
4-wire shielded cable 2 x 2 x 1.0mm2/17 AWG (approx. 2m delivered with instrument) |
Relay contacts | 6-wire shielded cable 6 x 0.25mm2 / 23 AWG (approx. 3m delivered with instrument) |
6-wire shielded cable 6 x 0.25mm2 / 23 AWG (approx. 3m delivered with instrument) |
|||
Relay outputs | Contacts | 3 x SPST (Single-Pole Single-Throw) |
3 x SPST (Single-Pole Single-Throw) |
||
Max. ratings | 250 VAC / 30 VDC, 2A |
250 VAC / 30 VDC, 2A |
|||
Graphic display | 122 x 32 dots with backlight |
122 x 32 dots with backlight |
122 x 32 dots with backlight |
122 x 32 dots with backlight |
|
Status LED | Green |
Green |
Green |
Green |
|
Keypad | 6 touch-sensitive membrane function keys |
6 touch-sensitive membrane function keys |
6 touch-sensitive membrane function keys |
6 touch-sensitive membrane function keys |
|
Physical dimensions LxWxD | Size | 145 x 95 x 50mm 5.7" x 3.7" x 2.0" |
145 x 95 x 50mm 5.7" x 3.7" x 2.0" |
145 x 95 x 50mm 5.7" x 3.7" x 2.0" |
145 x 95 x 50mm 5.7" x 3.7" x 2.0" |
Weight | 480g (17oz) |
650g (23oz) |
520g (18oz) |
620g (22oz) |
|
Mounting | Special mounting plate (delivered with instrument) |
Special mounting plate (delivered with instrument) |
Special mounting plate (delivered with instrument) |
Special mounting plate (delivered with instrument) |
|
Housing protection class | IP 52 (option: IP 65) | IP 52 (option: IP 65) |
IP 52 (option: IP 65) |
IP 52 (option: IP 65) |
|
RFI / EMC | EN 55022 EN 50082-2 |
EN 55022 EN 50082-2 |
EN 55022 EN 50082-2 |
EN 55022 EN 50082-2 |
|
Operating conditions | Temperature | -20°C up to +40°C -4°F up to +104°F |
-20°C up to +40°C -4°F up to +104°F |
-20°C up to +40°C -4°F up to +104°F |
-20°C up to +40°C -4°F up to +104°F |
Pressure | 700 up to 1300hPa |
700 up to 1300hPa |
700 up to 1300hPa |
700 up to 1300hPa |
|
Humidity | 20 up to 90% r.h. |
20 up to 90% r.h. |
20 up to 90% r.h. |
20 up to 90% r.h. |
|
Part number | 9602-0400 |
9602-0405 |
9602-0450 |
9602-0505 |